Piezoelectrically actuated dome-shaped diaphragm micropump

被引:55
作者
Feng, GH [1 ]
Kim, ES [1 ]
机构
[1] Univ So Calif, Dept Elect Engn Electrophys, Los Angeles, CA 90089 USA
关键词
ball; dome-shaped-diaphragm transducer (DSDT); micropump; parylene valves; piezoelectricity; three-dimensional (3-D) structure; wax; ZnO;
D O I
10.1109/JMEMS.2004.839331
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper describes a piezoelectric micropump built on a dome-shaped diaphragm with one-way parylene valves. The micropump uses piezoelectric ZnO film (less than 10 mu m thick) to actuate a parylene dome diaphragm, which is fabricated with an innovative, IC-compatible process on a silicon substrate. Piezoelectric ZnO film is sputter-deposited on a parylene dome diaphragm with its C-axis oriented perpendicular to the dome surface. Two one-way check valves (made of parylene) are integrated with a piezoelectrically actuated dome diaphragm to form a multi-chip micropump. The fabricated micropump (10 x 10 x 1.6 mm(3)) consumes extremely low power (i.e., 3 mW to pump 3.2 mu L/min) and shows negligible leak up to 700 Pa static differential pressure.
引用
收藏
页码:192 / 199
页数:8
相关论文
共 20 条
[1]  
ANDERS O, 1995, SENSOR ACTUAT A-PHYS, V46, P549
[2]  
Feng GH, 2003, PROC IEEE MICR ELECT, P594
[3]   Micropump based on PZT unimorph and one-way parylene valves [J].
Feng, GH ;
Kim, ES .
JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2004, 14 (04) :429-435
[4]  
HARRISON DJ, 1992, P IEEE SOL STAT SENS, P110
[5]   Fabrication and test of a thermopneumatic micropump with a corrugated p plus diaphragm [J].
Jeong, OC ;
Yang, SS .
SENSORS AND ACTUATORS A-PHYSICAL, 2000, 83 (1-3) :249-255
[6]   The dynamic micropump driven with a screen printed PZT actuator [J].
Koch, M ;
Evans, AGR ;
Brunnschweiler, A .
JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 1998, 8 (02) :119-122
[7]   A self-priming and bubble-tolerant piezoelectric silicon micropump for liquids and gases [J].
Linnemann, R ;
Woias, P ;
Senfft, CD ;
Ditterich, JA .
MICRO ELECTRO MECHANICAL SYSTEMS - IEEE ELEVENTH ANNUAL INTERNATIONAL WORKSHOP PROCEEDINGS, 1998, :532-537
[8]   Fabrication of TiNi shape memory micropump [J].
Makino, E ;
Mitsuya, T ;
Shibata, T .
SENSORS AND ACTUATORS A-PHYSICAL, 2001, 88 (03) :256-262
[9]  
MORONEY RM, 1992, P MEMS 91 NAR JAP, P277
[10]   PATIENT-CONTROLLED ANALGESIA USING A MINIATURE ELECTROCHEMICALLY DRIVEN INFUSION-PUMP [J].
OKEEFE, D ;
OHERLIHY, C ;
GROSS, Y ;
KELLY, JG .
BRITISH JOURNAL OF ANAESTHESIA, 1994, 73 (06) :843-846