High-efficiency single-cell entrapment and fluorescence in situ hybridization analysis using a poly(dimethylsiloxane) microfluidic device integrated with a black poly(ethylene terephthalate) micromesh

被引:48
作者
Matsunaga, Tadashi [1 ]
Hosokawa, Masahito [1 ]
Arakaki, Atsushi [1 ]
Taguchi, Tomoyuki [1 ]
Mori, Tetsushi [1 ]
Tanaka, Tsuyoshi [1 ]
Takeyama, Haruko [1 ]
机构
[1] Tokyo Univ Agr & Technol, Dept Biotechnol, Koganei, Tokyo 1848588, Japan
关键词
D O I
10.1021/ac800352j
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Here, we report a high-efficiency single-cell entrapment system with a poly(dimethylsiloxane) (PDMS) microfluidic device integrated with a micromesh, and its application to single-cell fluorescence in situ hybridization (FISH) analysis. A micromesh comprising of 10 x 10 microcavities was fabricated on a black poly(ethylene terephthalate) (PET) substrate by laser ablation. The cavity was approximately 2 mu m in diameter. Mammalian cells were driven and trapped onto the microcavities by applying negative pressure. Trapped cells were uniformly arrayed on the micromesh, enabling high-throughput microscopic analysis. Furthermore, we developed a method of PDMS surface modification by using air plasma and the copolymer Pluronic F-127 to prevent nonspecific adsorption on the PDMS microchannel. This method decreased the nonspecific adsorption of cells onto the microchannel to less than 1%. When cells were introduced into the microfluidic device integrated with the black PET micromesh, approximately 70-80% of the introduced cells were successfully trapped. Moreover, for mRNA expression analysis, on-chip fluorescence in situ hybridization (e.g., membrane permeabilization, hybridization, washing) can be performed in a microfluidic assay on an integrated device. Ibis microfluidic device has been employed for the detection of beta-actin mRNA expression in individual Raji cells. Differences in the levels of beta-actin mRNA expression were observed in serum-supplied or serum-starved cell populations.
引用
收藏
页码:5139 / 5145
页数:7
相关论文
共 37 条
[31]   Transcription factor profiling in individual hematopoietic progenitors by digital RT-PCR [J].
Warren, Luigi ;
Bryder, David ;
Weissman, Irving L. ;
Quake, Stephen R. .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2006, 103 (47) :17807-17812
[32]   Microchip device for cell lysis, multiplex PCR amplification, and electrophoretic sizing [J].
Waters, LC ;
Jacobson, SC ;
Kroutchinina, N ;
Khandurina, J ;
Foote, RS ;
Ramsey, JM .
ANALYTICAL CHEMISTRY, 1998, 70 (01) :158-162
[33]   Microfluidic device for single-cell analysis [J].
Wheeler, AR ;
Throndset, WR ;
Whelan, RJ ;
Leach, AM ;
Zare, RN ;
Liao, YH ;
Farrell, K ;
Manger, ID ;
Daridon, A .
ANALYTICAL CHEMISTRY, 2003, 75 (14) :3581-3586
[34]   Chemical cytometry on a picoliter-scale integrated microfluidic chip [J].
Wu, HK ;
Wheeler, A ;
Zare, RN .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2004, 101 (35) :12809-12813
[35]   Single-cell microarray for analyzing cellular response [J].
Yamamura, S ;
Kishi, H ;
Tokimitsu, Y ;
Kondo, S ;
Honda, R ;
Rao, SR ;
Omori, M ;
Tamiya, E ;
Muraguchi, A .
ANALYTICAL CHEMISTRY, 2005, 77 (24) :8050-8056
[36]   Probing gene expression in live cells, one protein molecule at a time [J].
Yu, J ;
Xiao, J ;
Ren, XJ ;
Lao, KQ ;
Xie, XS .
SCIENCE, 2006, 311 (5767) :1600-1603
[37]   Cell cycle regulation of chromatin at an origin of DNA replication [J].
Zhou, J ;
Chau, CM ;
Deng, Z ;
Shiekhattar, R ;
Spindler, MP ;
Schepers, A ;
Lieberman, PM .
EMBO JOURNAL, 2005, 24 (07) :1406-1417