Functionalised zinc oxide nanotube arrays as electrochemical sensors for the selective determination of glucose

被引:36
作者
Ali, S. M. U. [1 ,2 ]
Kashif, M. [3 ]
Ibupoto, Z. H. [1 ]
Fakhar-e-Alam, M. [1 ]
Hashim, U. [3 ]
Willander, M. [1 ]
机构
[1] Linkoping Univ, Phys Elect & Nanotechnol Div, Dept Sci & Technol, SE-60174 Norrkoping, Sweden
[2] NED Univ Engn & Technol, Dept Elect Engn, Karachi 75270, Pakistan
[3] Univ Malaysia Perlis, Nano Biochip Res Grp, Inst Nano Elect Engn, Kangar 01000, Perlis, Malaysia
关键词
AMPEROMETRIC ENZYME ELECTRODES; ZNO NANOWIRES; BIOSENSOR; IMMOBILIZATION; FERROCENE; SYSTEMS;
D O I
10.1049/mnl.2011.0310
中图分类号
TB3 [工程材料学];
学科分类号
082905 [生物质能源与材料];
摘要
In the present study, highly oriented single-crystal zinc oxide nanotube (ZnO-NT) arrays were prepared by a trimming of ZnO nanorods along the c-axis on the gold-coated glass substrate having a diameter of 100-200 nm and a length of similar to 1 mu m using a low-temperature aqueous chemical growth process. The prepared (ZnO-NT) arrays were further used as electrochemical enzyme-based glucose sensors through immobilisation of glucose oxidase by the physical adsorption method in conjunction with a Nafion coating. The electrochemical response of the sensor was found to be linear over a relatively wide logarithmic concentration range from 0.5 x 10(-6) to 12 x 10(-3) M. The proposed sensor showed a high sensitivity of 69.12 mV/decade with R = 0.9934 for sensing of glucose. A fast-response time less than 4 s with good selectivity, reproducibility and negligible response to common interferents such as ascorbic acid and uric acid prevailed.
引用
收藏
页码:609 / 613
页数:5
相关论文
共 46 条
[1]
A fast and sensitive potentiometric glucose microsensor based on glucose oxidase coated ZnO nanowires grown on a thin silver wire [J].
Ali, Syed M. Usman ;
Nur, O. ;
Willander, M. ;
Danielsson, B. .
SENSORS AND ACTUATORS B-CHEMICAL, 2010, 145 (02) :869-874
[2]
Intracellular K+ Determination With a Potentiometric Microelectrode Based on ZnO Nanowires [J].
Ali, Syed Muhammad Usman ;
Asif, Muhammad H. ;
Fulati, Alimujiang ;
Nur, Omer ;
Willander, Magnus ;
Brannmark, Cecilia ;
Stralfors, Peter ;
Englund, Ulrika H. ;
Elinder, Fredrik ;
Danielsson, Bengt .
IEEE TRANSACTIONS ON NANOTECHNOLOGY, 2011, 10 (04) :913-919
[3]
Glucose Detection With a Commercial MOSFET Using a ZnO Nanowires Extended Gate [J].
Ali, Syed Muhammad Usman ;
Nur, Omer ;
Willander, Magnus ;
Danielsson, Bengt .
IEEE TRANSACTIONS ON NANOTECHNOLOGY, 2009, 8 (06) :678-683
[4]
Amperometric enzyme electrodes for aerobic and anaerobic glucose monitoring prepared by glucose oxidase immobilized in mixed ferrocene-cobaltocenium dendrimers [J].
Alonso, B ;
Armada, PG ;
Losada, J ;
Cuadrado, I ;
González, B ;
Casado, CM .
BIOSENSORS & BIOELECTRONICS, 2004, 19 (12) :1617-1625
[5]
Functionalised ZnO-nanorod-based selective electrochemical sensor for intracellular glucose [J].
Asif, Muhammad H. ;
Ali, Syed M. Usman ;
Nur, Omer ;
Willander, Magnus ;
Brannmark, Cecilia ;
Stralfors, Peter ;
Englund, Ulrika H. ;
Elinder, Fredrik ;
Danielsson, Bengt .
BIOSENSORS & BIOELECTRONICS, 2010, 25 (10) :2205-2211
[6]
Broadband ZnO single-nanowire light-emitting diode [J].
Bao, Jiming ;
Zimmler, Mariano A. ;
Capasso, Federico ;
Wang, Xiaowei ;
Ren, Z. F. .
NANO LETTERS, 2006, 6 (08) :1719-1722
[7]
Layer-by-layer assembly of 1,4-diaminoanthraquinone and glucose oxidase [J].
Berchmans, S ;
Sathyajith, R ;
Yegnaraman, V .
MATERIALS CHEMISTRY AND PHYSICS, 2003, 77 (02) :390-396
[8]
FIELD-EFFECT TRANSISTOR SENSITIVE TO PENICILLIN [J].
CARAS, S ;
JANATA, J .
ANALYTICAL CHEMISTRY, 1980, 52 (12) :1935-1937
[9]
Chu Byung Hwan, 2010, J Diabetes Sci Technol, V4, P171
[10]
Biosensors in clinical chemistry [J].
D'Orazio, P .