Homogenous electrogenerated chemiluminescence immunoassay for human immunoglobulin G using N-(aminobutyl)-N-ethylisoluminol as luminescence label at gold nanoparticles modified paraffin-impregnated graphite electrode

被引:25
作者
Qi, Honglan [1 ]
Zhang, Yi [1 ]
Peng, Yage [1 ]
Zhang, Chengxiao [1 ]
机构
[1] Shaanxi Normal Univ, Sch Chem & Mat Sci, Key Lab Analyt Chem Life Sci Shaanxi Prov, Xian 710062, Peoples R China
基金
中国国家自然科学基金;
关键词
D O I
10.1016/j.talanta.2007.12.002
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A homogeneous electrogenerated chemiluminescence (ECL) immunoassay for human immunoglobulin G (hIgG) has been developed using a N-(aminobutyl)-N-ethylisoluminol (ABEI) as luminescence label at gold nanoparticles modified paraffin-impregnated graphite electrode (PIGE). ECL emission was electrochemically generated from the ABEI-labeled anti-hIgG antibody and markedly increased in the presence of hIgG antigen due to forming a more rigid structure of the ABEI moiety. The concentration of hIgG antigen was determined by the increase of ECL intensity at a gold nanoparticles modified PIGE. It was found that the ECL intensity of ABEI in presence of hydrogen peroxide was dramatically enhanced at Gold nanoparticles modified PIGE in neutral aqueous solution and the detection limit of ABEI was 2 x 10(-14) mol/L (S/N = 3). The integral ECL intensity was linearly related to the concentration of hIgG antigen from 3.0 x 10(-11) to 1.0 x 10(-9) g/mL with a detection limit of 1 x 10(-11) g/mL (S/N = 3). The relative standard deviation was 3.1% at 1.0 x 10(-10) g/mL (n = I I). This work demonstrates that the enhancement of the sensitivity of ECL and ECL immunoassay at a nanoparticles modified electrode is a promising strategy. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:684 / 690
页数:7
相关论文
共 21 条
[11]   Nanoparticles as structural and functional units in surface-confined architectures [J].
Shipway, AN ;
Willner, I .
CHEMICAL COMMUNICATIONS, 2001, (20) :2035-2045
[12]   Liquid chromatography with luminol-based electrochemiluminescence detection - Determination of histamine [J].
Steijger, OM ;
Kamminga, DA ;
Brumelhuis, A ;
Lingeman, H .
JOURNAL OF CHROMATOGRAPHY A, 1998, 799 (1-2) :57-66
[13]   MULTILABELING OF FERROCENES TO A GLUCOSE-OXIDASE DIGOXIN CONJUGATE FOR THE DEVELOPMENT OF A HOMOGENEOUS ELECTROENZYMATIC IMMUNOASSAY [J].
SUZAWA, T ;
IKARIYAMA, Y ;
AIZAWA, M .
ANALYTICAL CHEMISTRY, 1994, 66 (22) :3889-3894
[14]   Electrogenerated chemiluminescence of luminol in neutral and alkaline aqueous solutions on a silver nanoparticle self-assembled gold electrode [J].
Wang, Cheng-Ming ;
Cui, Hua .
LUMINESCENCE, 2007, 22 (01) :35-45
[15]   ELECTROCHEMILUMINESCENCE - A NEW DIAGNOSTIC AND RESEARCH TOOL [J].
YANG, HJ ;
LELAND, JK ;
YOST, D ;
MASSEY, RJ .
BIO-TECHNOLOGY, 1994, 12 (02) :193-194
[16]   Study on the electrochemiluminescence behavior of ABEI and its application in DNA hybridization analysis [J].
Yang, ML ;
Liu, CZ ;
Qian, KJ ;
He, PG ;
Fang, YZ .
ANALYST, 2002, 127 (09) :1267-1271
[17]   4-(Dimethylamino)butyric acid labeling for electrochemiluminescence detection of biological substances by increasing sensitivity with gold nanoparticle amplification [J].
Yin, XB ;
Qi, B ;
Sun, XP ;
Yang, XR ;
Wang, EK .
ANALYTICAL CHEMISTRY, 2005, 77 (11) :3525-3530
[18]   Detection of biological threat agents by immunomagnetic microsphere-based solid phase fluorogenic- and electro-chemiluminescence [J].
Yu, H ;
Raymonda, JW ;
McMahon, TM ;
Campagnari, AA .
BIOSENSORS & BIOELECTRONICS, 2000, 14 (10-11) :829-840
[19]   Homogeneous electrogenerated chemiluminescence immunoassay for the determination of digoxin emploting Ru(bpy)2(dcbpy)NHS and carrier protein [J].
Zhang, Chengxiao ;
Qi, Honglan ;
Zhang, Meining .
LUMINESCENCE, 2007, 22 (01) :53-59
[20]   Homogeneous electrogenerated chemiluminescence immunoassay using a luminol-labeled digoxin hapten [J].
Zhang, CX ;
Zhang, HH ;
Feng, ML .
ANALYTICAL LETTERS, 2003, 36 (06) :1103-1114