Stent Coverage and Neointimal Proliferation in Bare Metal Stents Postdilated With a Paclitaxel-Eluting Balloon Versus Everolimus-Eluting Stents Prospective Randomized Study Using Optical Coherence Tomography at 6-Month Follow-Up

被引:28
作者
Poerner, Tudor C. [1 ]
Otto, Sylvia
Gassdorf, Johannes [1 ]
Nitsche, Kristina [1 ]
Janiak, Florian [1 ]
Scheller, Bruno [2 ]
Goebel, Bjoern [1 ]
Jung, Christian [1 ]
Figulla, Hans R. [1 ]
机构
[1] Univ Hosp Jena, Dept Med 1, Div Cardiol, Jena, Germany
[2] Univ Saarland, D-66123 Saarbrucken, Germany
关键词
coronary stenosis; drug-eluting stents; percutaneous coronary intervention; tomography; optical coherence; transluminal coronary balloon dilation; PERCUTANEOUS CORONARY INTERVENTION; DUAL-ANTIPLATELET THERAPY; COATED BALLOON; CONVENTIONAL ANGIOPLASTY; ARTERY-DISEASE; RESTENOSIS; LESIONS; TRIAL; IMPLANTATION; REVASCULARIZATION;
D O I
10.1161/CIRCINTERVENTIONS.113.001146
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-In this randomized trial, strut coverage and neointimal proliferation of a therapy of bare metal stents (BMSs) postdilated with the paclitaxel drug-eluting balloon (DEB) was compared with everolimus drug-eluting stents (DESs) at 6-month follow-up using optical coherence tomography. We hypothesized sufficient stent coverage at follow-up. Methods and Results-A total of 105 lesions in 90 patients were treated with either XIENCE V DES (n=51) or BMS postdilated with the SeQuent Please DEB (n=54). At follow-up, comparable results on the primary optical coherence tomography end point (percentage uncovered struts 5.64+/-9.65% in BMS+DEB versus 4.93+/-9.29% in DES; P=0.366) were found. Thus, BMS+DEB achieved the prespecified noninferiority margin of 5% uncovered struts versus DES (difference between treatment means, 0.71%; one-sided upper 95% confidence interval, 4.14%; noninferiority P=0.04). Optical coherence tomography analysis showed significantly more global neointimal proliferation in the BMS+DEB group (15.7+/-7.8 versus 11.0+/-5.2 mm(3) proliferation volume/cm stent length; P=0.002). No significant focal in-stent stenosis analyzed with angiography (percentage diameter stenosis at follow-up, 22.8+/-11.9 versus 16.9+/-10.4; P=0.014) and optical coherence tomography (peak local area stenosis, 39.5+/-13.8% versus 36.8+/-15.6%; P=0.409) was found. Conclusions-Good stent strut coverage of >94% was found in both therapy groups. Despite greater suppression of global neointimal growth in DES, both DES and BMS+DEB effectively prevented clinically relevant focal restenosis at 6-month follow-up.
引用
收藏
页码:760 / U53
页数:10
相关论文
共 34 条
[1]  
Ali RM, 2011, EUROINTERVENTION, V7, pK83, DOI 10.4244/EIJV7SKA15
[2]   Clinical Safety and Efficacy of a Novel Thin-Strut Cobalt-Chromium Coronary Stent System: Results of the real world coroflex blue registry [J].
Bocksch, Wolfgang ;
Pomar, Francisco ;
Dziarmaga, Mieczyslaw ;
Tresukosol, Damras ;
Ismail, Omar ;
Janek, Bronislav ;
Carlsson, Joerg ;
Simon, Jean-Philippe .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2010, 75 (01) :78-85
[3]   Influence of a Paclitaxel Coated Balloon in Combination With a Bare Metal Stent on Restenosis and Endothelial Function: Comparison With a Drug Eluting Stent and a Bare Metal Stent [J].
Clever, Yvonne P. ;
Cremers, Bodo ;
Speck, Ulrich ;
Dietz, Ulrich ;
Boehm, Michael ;
Scheller, Bruno .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2014, 84 (02) :323-331
[4]   Clopidogrel use and long-term clinical outcomes after drug-eluting stent implantation [J].
Eisenstein, Eric L. ;
Anstrom, Kevin J. ;
Kong, David F. ;
Shaw, Linda K. ;
Tuttle, Robert H. ;
Mark, Daniel B. ;
Kramer, Judith M. ;
Harrington, Robert A. ;
Matchar, David B. ;
Kandzari, David E. ;
Peterson, Eric D. ;
Schulman, Kevin A. ;
Califf, Robert M. .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2007, 297 (02) :159-168
[5]   Paclitaxcel-coated balloon plus bare metal stent vs. sirolimus-eluting stent in de novo lesions: an IVUS study [J].
Fischer, Dieter ;
Scheller, Bruno ;
Schaefer, Arnd ;
Klein, Gunnar ;
Boehm, Michael ;
Clever, Yvonne ;
Cremers, Bodo .
EUROINTERVENTION, 2012, 8 (04) :450-455
[6]   Drug eluting balloons for de novo coronary lesions - a systematic review and meta-analysis [J].
Froehlich, Georg M. ;
Lansky, Alexandra J. ;
Ko, Dennis T. ;
Archangelidi, Olga ;
De Palma, Rodney ;
Timmis, Adam ;
Meier, Pascal .
BMC MEDICINE, 2013, 11
[7]   LESION-TO-LESION INDEPENDENCE OF RESTENOSIS AFTER TREATMENT BY CONVENTIONAL ANGIOPLASTY, STENTING, OR DIRECTIONAL ATHERECTOMY - VALIDATION OF LESION-BASED RESTENOSIS ANALYSIS [J].
GIBSON, CM ;
KUNTZ, RE ;
NOBUYOSHI, M ;
ROSNER, B ;
BAIM, DS .
CIRCULATION, 1993, 87 (04) :1123-1129
[8]   Vascular Tissue Reaction to Acute Malapposition in Human Coronary Arteries Sequential Assessment With Optical Coherence Tomography [J].
Gutierrez-Chico, Juan Luis ;
Wykrzykowska, Joanna ;
Nueesch, Eveline ;
van Geuns, Robert Jan ;
Koch, Karel T. ;
Koolen, Jacques J. ;
di Mario, Carlo ;
Windecker, Stephan ;
van Es, Gerrit-Anne ;
Gobbens, Pierre ;
Jueni, Peter ;
Regar, Evelyn ;
Serruys, Patrick W. .
CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2012, 5 (01) :20-U81
[9]   Paclitaxel-coated balloon in combination with bare metal stent for treatment of de novo coronary lesions: an optical coherence tomography first-in-human randomised trial, balloon first vs. stent first [J].
Gutierrez-Chico, Juan Luis ;
van Geuns, Robert Jan ;
Koch, Karel T. ;
Koolen, Jacques J. ;
Duckers, Henricus ;
Regar, Evelyn ;
Serruys, Patrick W. .
EUROINTERVENTION, 2011, 7 (06) :711-722
[10]   Delayed Coverage in Malapposed and Side-Branch Struts With Respect to Well-Apposed Struts in Drug-Eluting Stents In Vivo Assessment With Optical Coherence Tomography [J].
Gutierrez-Chico, Juan Luis ;
Regar, Evelyn ;
Nueesch, Eveline ;
Okamura, Takayuki ;
Wykrzykowska, Joanna ;
di Mario, Carlo ;
Windecker, Stephan ;
van Es, Gerrit-Anne ;
Gobbens, Pierre ;
Jueni, Peter ;
Serruys, Patrick W. .
CIRCULATION, 2011, 124 (05) :612-U192