Noninvasive glucose sensing

被引:133
作者
Arnold, MA [1 ]
Small, GW
机构
[1] Univ Iowa, Dept Chem, Iowa City, IA 52242 USA
[2] Univ Iowa, Opt Sci & Technol Ctr, Iowa City, IA 52242 USA
关键词
D O I
10.1021/ac050429e
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The ability to measure glucose noninvasively in human subjects is a major objective for many research groups. Success will revolutionize the treatment of diabetes by providing a means to improve glycemic control, thereby delaying the onset of the medical complications associated with this disease. This article focuses on the current state of the art and attempts to identify the principal areas of research necessary to advance the field. Two fundamentally different approaches are identified for the development of noninvasive glucose sensing technology. The indirect approach attempts to measure glucose on the basis of its effect on a secondary process. The direct approach is based on the unique chemical structure of the glucose molecule. Advances for each approach are limited by issues of selectivity. Several critical parameters are discussed for the direct approach, including issues related to the optical path length, wavelength range, dimensionality of the multivariate calibration model, net analyte signal, spectral variance, and assessment of the chemical basis of measurement selectivity. A set of publication standards is recommended as a means to enhance progress toward a successful noninvasive monitor.
引用
收藏
页码:5429 / 5439
页数:11
相关论文
共 43 条
[21]   TELEDYNE SLEEP SENTRY - EVALUATION IN PEDIATRIC-PATIENTS FOR DETECTION OF NOCTURNAL HYPOGLYCEMIA [J].
HANSEN, KA ;
DUCK, SC .
DIABETES CARE, 1983, 6 (06) :597-600
[22]   Dielectric spectroscopy study of specific glucose influence on human erythrocyte membranes [J].
Hayashi, Y ;
Livshits, L ;
Caduff, A ;
Feldman, Y .
JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2003, 36 (04) :369-374
[23]   Non-invasive monitoring of metabolites using near infrared spectroscopy: State of the art [J].
Heise, HM .
HORMONE AND METABOLIC RESEARCH, 1996, 28 (10) :527-534
[24]   NONINVASIVE BLOOD-GLUCOSE SENSORS BASED ON NEAR-INFRARED SPECTROSCOPY [J].
HEISE, HM ;
MARBACH, R ;
KOSCHINSKY, T ;
GRIES, FA .
ARTIFICIAL ORGANS, 1994, 18 (06) :439-447
[25]   Temperature-independent near-infrared analysis of lysozyme aqueous solutions [J].
Hu, SYB ;
Arnold, MA ;
Wiencek, JM .
ANALYTICAL CHEMISTRY, 2000, 72 (04) :696-702
[26]   Error detection and measurement in glucose monitors [J].
Johnson, RN ;
Baker, JR .
CLINICA CHIMICA ACTA, 2001, 307 (1-2) :61-67
[27]  
Khalil Omar S, 2004, Diabetes Technol Ther, V6, P660, DOI 10.1089/dia.2004.6.660
[28]  
Khalil OS, 1999, CLIN CHEM, V45, P165
[29]   INFLUENCE OF GLUCOSE-CONCENTRATION ON LIGHT-SCATTERING IN TISSUE-SIMULATING PHANTOMS [J].
KOHL, M ;
COPE, M ;
ESSENPREIS, M ;
BOCKER, D .
OPTICS LETTERS, 1994, 19 (24) :2170-2172
[30]   THE INFLUENCE OF GLUCOSE-CONCENTRATION UPON THE TRANSPORT OF LIGHT IN TISSUE-SIMULATING PHANTOMS [J].
KOHL, M ;
ESSENPREIS, M ;
COPE, M .
PHYSICS IN MEDICINE AND BIOLOGY, 1995, 40 (07) :1267-1287