Comparison between the loading capacities of columns packed with partially and totally porous fine particles what is the effective surface area available for adsorption?

被引:70
作者
Gritti, Fabrice [1 ,2 ]
Guiochon, Georges [1 ,2 ]
机构
[1] Univ Tennessee, Dept Chem, Knoxville, TN 37996 USA
[2] Oak Ridge Natl Lab, Div Chem Sci, Oak Ridge, TN 37831 USA
基金
美国国家科学基金会;
关键词
adsorption isotherm; adsorption energy distribution; column loading; shell particles; specific surface area; nitrogen sorptometry; ISEC; saturation capacity; RP-HPLC; Luna(2)-C-18; Halo-C-18; phenol; caffeine; insulin; lysozyme;
D O I
10.1016/j.chroma.2007.10.076
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The adsorption isotherms of phenol, caffeine, insulin, and lysozyme were measured on two C-18-bonded silica columns. The first one was packed with classical totally porous particles (3 mu m Luna(2)-C-18 from Phenomenex, Torrance, CA, USA), the second one with shell particles (2.7 mu m Halo-C-18 from Advanced Materials Technology, Wilmington, DE, USA). The measurements were made at room temperature (T = 295 +/- 1 K), using mainly frontal analysis (FA) and also elution by characteristic points (FACP) when necessary. The adsorption energy distributions (AEDs) were estimated by the iterative numerical expectation-maximization (EM) procedure and served to justify the choice of the best adsorption isotherm model for each compound. The best isotherm parameters were derived from either the best fit of the experimental data to a multi-Langmuir isotherm model (MLRA) or from the AED results (equilibrium constants and saturation capacities), when the convergence of the EM program was achieved. The experiments show than the loading capacity of the Luna column is more than twice that of the Halo column for low-molecular-weight compounds. This result was expected; it is in good agreement with the values of the accessible surface area of these two materials, which were calculated from the pore size volume distributions. The pore size volume distributions are validated by the excellent agreement between the calculated and measured exclusion volumes of polystyrene standards by inverse size exclusion chromatography (ISEC). In contrast, the loading capacity ratio of the two columns is 1.5 or less with insulin and lysozyme. This is due to a significant exclusion of these two proteins from the internal pore volumes of the two packing materials. This result raises the problem of the determination of the effective surface area of the packing material, particularly in the case of proteins. This area is about 40 and 30% of the total surface area for insulin and for lysozyme, respectively, based on the pore size volume distribution validated by the ISEC method. The ISEC experiments showed that the largest and the smallest mesopores have rather a cylindrical and a spherical shape, respectively, for both packing materials. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:107 / 122
页数:16
相关论文
共 21 条
[11]  
KIRKLAND JJ, 2006, 58 PITTC C CHIC IL F
[12]   THEORY OF SOLVENT DISTURBANCE PEAKS AND EXPERIMENTAL-DETERMINATION OF THERMODYNAMIC DEAD-VOLUME IN COLUMN LIQUID-CHROMATOGRAPHY [J].
KNOX, JH ;
KALISZAN, R .
JOURNAL OF CHROMATOGRAPHY, 1985, 349 (02) :211-234
[13]  
KNOX JH, 2006, J CHROMATOGR A, V1115, P142
[14]   DIFFUSION OF POLYSTYRENE IN TETRAHYDROFURAN [J].
MANDEMA, W ;
ZELDENRUST, H .
POLYMER, 1977, 18 (08) :835-839
[15]  
MARCHETTI N, 2007, ANAL CHEM, V1163, P203
[16]   The measurement and meaning of void volumes in reversed-phase liquid chromatography [J].
Rimmer, CA ;
Simmons, CR ;
Dorsey, JG .
JOURNAL OF CHROMATOGRAPHY A, 2002, 965 (1-2) :219-232
[17]   Geometry of chemically modified silica [J].
Rustamov, I ;
Farcas, T ;
Ahmed, F ;
Chan, F ;
LoBrutto, R ;
McNair, HM ;
Kazakevich, YV .
JOURNAL OF CHROMATOGRAPHY A, 2001, 913 (1-2) :49-63
[18]   A REVIEW OF METHODS FOR THE DETERMINATION OF HOLD-UP VOLUME IN MODERN LIQUID-CHROMATOGRAPHY [J].
SMITH, RJ ;
NIEASS, CS ;
WAINWRIGHT, MS .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1986, 9 (07) :1387-1430
[19]  
STANLEY BJ, 1994, ANAL CHEM, V659, P27
[20]   Oxidative cleavage of carbon-silicon bond as a new method to characterize bonded stationary phases on silica gel [J].
Yang, AL ;
Li, TY .
ANALYTICAL CHEMISTRY, 1998, 70 (14) :2827-2830