Dual-source CT coronary angiography: Image quality, mean heart rate, and heart rate variability

被引:128
作者
Matt, David
Scheffel, Hans
Leschka, Sebastian
Flohr, Thomas G.
Marincek, Borut
Kaufmann, Philipp A.
Alkadhi, Hatem
机构
[1] Univ Zurich Hosp, Inst Diagnost Radiol, CH-8091 Zurich, Switzerland
[2] Siemens Med Solut, Forchheim, Germany
[3] Univ Zurich Hosp, Ctr Cardiovasc, CH-8091 Zurich, Switzerland
[4] Zurich Ctr Integrat Human Physiol, Zurich, Switzerland
关键词
coronary angiography; dual-source CT; heart rate; image quality;
D O I
10.2214/AJR.07.2078
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study was to evaluate the effect of mean heart rate and heart rate variability on the image quality of dual-source CT coronary angiography. SUBJECTS AND METHODS. Eighty patients underwent dual-source CT coronary angiography. Thirteen data sets were reconstructed in 5% steps from 20-80% of the R-R interval. Heart rate variability was calculated as SD of mean heart rate. Two independent blinded reviewers assessed the image quality of each segment. RESULTS. Mean heart rate was 65.3 +/- 13.9 (SD) beats per minute (bpm) (range, 35-99 bpm) with a variability of 3.4 +/- 4.1 bpm (range, 0.4-17.5 bpm). Image quality was sufficient for diagnosis for 97.8% (1,043/1,066) of arterial segments. No significant correlation was found between mean heart rate and image quality in any segment or any coronary artery. No significant correlation was found between heart rate variability and image quality in any segment, the right coronary artery, or the left anterior descending artery, but there was a significant (p < 0.05) correlation in the left circumflex artery. A significant correlation (p < 0.05) between overall image quality was found for mean and variability of heart rate as shared predictors, the latter having a greater contribution. CONCLUSION. The overall image quality of dual-source CT coronary angiography is sufficient for diagnosis within a wide range of mean heart rates and variability of heart rates. Only heart rates that are both high and variable significantly deteriorate image quality, but the quality remains adequate for diagnosis.
引用
收藏
页码:567 / 573
页数:7
相关论文
共 28 条
[1]   Contrast-enhanced coronary artery visualization by dual-source computed tomography - Initial experience [J].
Achenbach, S ;
Ropers, D ;
Kuettner, A ;
Flohr, T ;
Ohnesorge, B ;
Bruder, H ;
Theessen, H ;
Karakaya, M ;
Daniel, WG ;
Bautz, W ;
Kalender, WA ;
Anders, K .
EUROPEAN JOURNAL OF RADIOLOGY, 2006, 57 (03) :331-335
[2]   In-plane coronary arterial motion velocity: Measurement with electron-beam CT [J].
Achenbach, S ;
Ropers, D ;
Holle, J ;
Muschiol, G ;
Daniel, WG ;
Moshage, W .
RADIOLOGY, 2000, 216 (02) :457-463
[3]  
Austen W G, 1975, Circulation, V51, P5
[4]   Cardiac Imaging 2006 [J].
Colletti, PM .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 186 (06) :S337-S339
[5]   Heart rate adaptive optimization of spatial and temporal resolution for electrocardiogram-gated multislice spiral CT of the heart [J].
Flohr, T ;
Ohnesorge, B .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2001, 25 (06) :907-923
[6]   First performance evaluation of a dual-source CT (DSCT) system [J].
Flohr, TG ;
McCollough, CH ;
Bruder, H ;
Petersilka, M ;
Gruber, K ;
Süss, C ;
Grasruck, M ;
Stierstorfer, K ;
Krauss, B ;
Raupach, R ;
Primak, AN ;
Küttner, A ;
Achenbach, S ;
Becker, C ;
Kopp, A ;
Ohnesorge, BM .
EUROPEAN RADIOLOGY, 2006, 16 (02) :256-268
[7]   ACCF/ACR/SCCT/SCMR/ASNC/NASCI/SCAI/SIR 2006 appropriateness criteria for cardiac computed tomography and cardiac magnetic resonance imaging - A report of the American College of Cardiology Foundation Quality Strategic Directions Committee Appropriateness Criteria Working Group, American College of Radiology, Society of Cardiovascular Computed Tomography, Society for Cardiovascular Magnetic Resonance, American Society of Nuclear Cardiology, North American Society for Cardiac Imaging, Society for Cardiovascular Angiography and Interventions, and Society of Interventional Radiology [J].
Hendel, Robert C. ;
Patel, Manesh R. ;
Kramer, Christopher M. ;
Poon, Michael ;
Hendel, Robert C. ;
Brindis, Ralph G. ;
Hendel, Robert C. ;
Douglas, Pamela S. ;
Peterson, Eric D. ;
Wolk, Michael J. ;
Allen, Joseph M. ;
Patel, Manesh R. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 48 (07) :1475-1497
[8]   Multi-detector row CT coronary angiography: Influence of reconstruction technique and heart rate on image quality [J].
Herzog, C ;
Arning-Erb, M ;
Zangos, S ;
Eichler, K ;
Hammerstingl, R ;
Dogan, S ;
Ackermann, H ;
Vogl, TJ .
RADIOLOGY, 2006, 238 (01) :75-86
[9]   Noninvasive coronary angiography with 16-detector row CT: Effect of heart rate [J].
Hoffmann, MHK ;
Shi, HS ;
Manzke, R ;
Schmid, FT ;
De Vries, L ;
Grass, M ;
Brambs, HR ;
Aschoff, AJ .
RADIOLOGY, 2005, 234 (01) :86-97
[10]   ECG-gated reconstructed multi-detector row CT coronary angiography:: Effect of varying trigger delay on image quality [J].
Hong, C ;
Becker, CR ;
Huber, A ;
Schoepf, UJ ;
Ohnesorge, B ;
Knez, A ;
Brüning, R ;
Reiser, MF .
RADIOLOGY, 2001, 220 (03) :712-717