Whole-body MRI at high field: technical limits and clinical potential

被引:238
作者
Schick, F [1 ]
机构
[1] Univ Tubingen, Dept Diagnost Radiol, Sect Expt Radiol, Tubingen, Germany
关键词
magnetic resonance imaging; magnetic resonance spectroscopy; high-field magnetic resonance imaging; whole-body imaging; dielectric effects;
D O I
10.1007/s00330-005-2678-0
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This review seeks to clarify the most important implications of higher magnetic field strength for clinical examinations of the whole body. An overview is provided on the resulting advantages and disadvantages for anatomical, functional and biochemical magnetic resonance examinations in different regions of the body. It is demonstrated that susceptibility-dependent imaging, chemical shift selective (e.g., fat-suppressed) imaging, and spectroscopic techniques clearly gain from higher field strength. Problems due to shorter wavelength and higher radio frequency energy deposition at higher field strength are reported, especially in examinations of the body trunk. Thorax examinations provided sufficient homogeneity of the radio frequency field for common examination techniques in most cases, whereas abdominal and pelvic imaging was often hampered by undesired dielectric effects. Currently available and potential future strategies to overcome related limitations are discussed. Whole-body MRI at higher field strength currently leads to clearly improved image quality using a variety of established sequence types and for examination of many body regions. But some major problems at higher field strength have to be solved before high-field magnetic resonance systems can really replace the well-established and technically developed magnetic resonance systems operating at 1.5 T for each clinical application.
引用
收藏
页码:946 / 959
页数:14
相关论文
共 65 条
[31]   Acute vestibular neuritis visualized by 3-T magnetic resonance imaging with high-dose gadolinium [J].
Karlberg, M ;
Annertz, M ;
Magnusson, M .
ARCHIVES OF OTOLARYNGOLOGY-HEAD & NECK SURGERY, 2004, 130 (02) :229-232
[32]   High-field magnetic resonance techniques for brain research [J].
Kim, DS ;
Garwood, M .
CURRENT OPINION IN NEUROBIOLOGY, 2003, 13 (05) :612-619
[33]   High-resolution blood flow velocity measurements in the human finger [J].
Klarhöfer, M ;
Csapo, B ;
Balassy, C ;
Szeles, JC ;
Moser, E .
MAGNETIC RESONANCE IN MEDICINE, 2001, 45 (04) :716-719
[34]   Combined magnetic resonance imaging and spectroscopic imaging approach to molecular imaging of prostate cancer [J].
Kurhanewicz, J ;
Swanson, MG ;
Nelson, SJ ;
Vigneron, DB .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2002, 16 (04) :451-463
[35]   3.0 T high-resolution MR imaging of carpal ligaments and TFCC [J].
Lenk, S ;
Ludescher, B ;
Martirosan, P ;
Schick, F ;
Claussen, CD ;
Schlemmer, HP .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2004, 176 (05) :664-667
[36]  
Lin Weili, 2003, Magn Reson Imaging Clin N Am, V11, P615, DOI 10.1016/S1064-9689(03)00068-0
[37]   Lung MRI at 3.0 T: a comparison of helical CT and high-field MRI in the detection of diffuse lung disease [J].
Lutterbey, G ;
Gieseke, J ;
von Falkenhausen, M ;
Morakkabati, N ;
Schild, H .
EUROPEAN RADIOLOGY, 2005, 15 (02) :324-328
[38]   FAIR true-FISP perfusion imaging of the kidneys [J].
Martirosian, P ;
Klose, U ;
Mader, I ;
Schick, F .
MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (02) :353-361
[39]   High field MRI in preclinical research [J].
Marzola, P ;
Osculati, F ;
Sbarbati, A .
EUROPEAN JOURNAL OF RADIOLOGY, 2003, 48 (02) :165-170
[40]   Proton T2 relaxation study of water, N-acetylaspartate, and creatine in human brain using Hahn and Carr-Purcell spin echoes at 4T and 7T [J].
Michaeli, S ;
Garwood, M ;
Zhu, XH ;
DelaBarre, L ;
Andersen, P ;
Adriany, G ;
Merkle, H ;
Ugurbil, K ;
Chen, W .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (04) :629-633