Improved temporal resolution for in vivo microdialysis by using segmented flow

被引:96
作者
Wang, Meng [1 ]
Roman, Gregory T. [1 ]
Schultz, Kristin [1 ]
Jennings, Colin [1 ]
Kennedy, Robert T. [1 ,2 ]
机构
[1] Univ Michigan, Dept Chem, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Dept Pharmacol, Ann Arbor, MI 48109 USA
关键词
D O I
10.1021/ac800622s
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Microdialysis sampling probes were interfaced to a segmented flow system to improve temporal resolution for monitoring concentration dynamics. Aqueous dialysate was segmented into nanoliter plugs by pumping sample stream into the base of a tee channel structure microfabricated on a PDMS chip that had an immiscible carrier phase (perfluorodecalin) pumped into the cross arm of the tee. Varying the oil flow rate from 0.22 to 6.3 mu L/min and sample flow rate from 42 to 328 nL/min allowed control of plug volume, interval between plugs, and frequency of plug generation between 6 and 28 nL, 0.6 and 10 s, and 0.1 and 1.7 Hz, respectively. Temporal resolution of the system, determined by measuring fluorescence in individual sample plugs following step changes of fluorescein concentration at the sampling probe surface, was as good as 15 s. Temporal resolution was independent of both sampling flow rate and distance that samples were pumped from the sampling probe. This effect is due to the prevention of Taylor dispersion of the sample as it was transported by segmented flow. In contrast, without flow segmentation, temporal resolution was worsened from 25 to 160 s as the detection point was moved from the sampling probe to 40 cm downstream. Glucose was detected by modifying the chip to allow enzyme assay reagents to be mixed with dialysate as sample plugs formed. The resulting assay had a detection limit of 50 mu M and a linear range of 0.2-2 mM. Ibis system was used to measure glucose in the brain of anesthetized rats. Basal concentration was 1.5 +/- 0.1 mM (n = 3) and was decreased 60% by infusion of high-K+ solution through the probe. These results demonstrate the potential of microdialysis with segmented flow to be used for in vivo monitoring experiments with high temporal resolution.
引用
收藏
页码:5607 / 5615
页数:9
相关论文
共 64 条
[31]   Demonstration of low flow push-pull perfusion [J].
Kottegoda, S ;
Shaik, I ;
Shippy, SA .
JOURNAL OF NEUROSCIENCE METHODS, 2002, 121 (01) :93-101
[32]   Integrated continuous microfluidic liquid-liquid extraction [J].
Kralj, Jason G. ;
Sahoo, Hemantkumar R. ;
Jensen, Klavs F. .
LAB ON A CHIP, 2007, 7 (02) :256-263
[33]   High temporal resolution monitoring of glutamate and aspartate in vivo using microdialysis on-line with capillary electrophoresis with laser-induced fluorescence detection [J].
Lada, MW ;
Vickroy, TW ;
Kennedy, RT .
ANALYTICAL CHEMISTRY, 1997, 69 (22) :4560-4565
[34]   Using a multijunction microfluidic device to inject substrate into an array of preformed plugs without cross-contamination: Comparing theory and experiments [J].
Li, Liang ;
Boedicker, James Q. ;
Ismagilov, Rustem F. .
ANALYTICAL CHEMISTRY, 2007, 79 (07) :2756-2761
[35]   Poly(dimethylsiloxane) as a material for fabricating microfluidic devices [J].
McDonald, JC ;
Whitesides, GM .
ACCOUNTS OF CHEMICAL RESEARCH, 2002, 35 (07) :491-499
[36]   Extracellular glucose concentrations in the rat hippocampus measured by zero-net-flux: Effects of microdialysis flow rate, strain, and age [J].
McNay, EC ;
Gold, PE .
JOURNAL OF NEUROCHEMISTRY, 1999, 72 (02) :785-790
[37]   Decreases in rat extracellular hippocampal glucose concentration associated with cognitive demand during a spatial task [J].
McNay, EC ;
Fries, TM ;
Gold, PE .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2000, 97 (06) :2881-2885
[38]   Glucose recovery with bare and hydrogel-coated microdialysis probes: Experiment and simulation of temporal effects [J].
Norton, Lori W. ;
Yuan, Fan ;
Reichert, W. Monty .
ANALYTICAL CHEMISTRY, 2007, 79 (02) :445-452
[39]   Dynamic changes in brain glucose and lactate in pericontusional areas of the human cerebral cortex, monitored with rapid sampling on-line microdialysis: relationship with depolarisation-like events [J].
Parkin, MC ;
Hopwood, SE ;
Jones, DA ;
Hashemi, P ;
Landolt, H ;
Fabricius, M ;
Lauritzen, M ;
Boutelle, MG ;
Strong, AJ .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2005, 25 (03) :402-413
[40]   EXTRACELLULAR CONCENTRATION AND INVIVO RECOVERY OF DOPAMINE IN THE NUCLEUS-ACCUMBENS USING MICRODIALYSIS [J].
PARSONS, LH ;
JUSTICE, JB .
JOURNAL OF NEUROCHEMISTRY, 1992, 58 (01) :212-218