Minimizing artifacts caused by metallic implants at MR imaging: Experimental and clinical studies

被引:142
作者
Suh, JS
Jeong, EK
Shin, KH
Cho, JH
Na, JB
Kim, DH
Han, CD
机构
[1] Yonsei Univ, Coll Med, Dept Diagnost Radiol, Seoul 120752, South Korea
[2] Yonsei Univ, Coll Med, Res Inst Radiol Sci, Seoul, South Korea
[3] Yonsei Univ, Coll Med, Dept Orthoped Surg, Seoul, South Korea
关键词
D O I
10.2214/ajr.171.5.9798849
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study was to investigate the effect of metallic implant positioning on MR imaging artifacts, to determine the optimal imaging conditions for minimizing artifacts, and to show the usefulness of artifact-minimizing methods in imaging of the knee. MATERIALS AND METHODS. Using MR images of experimental phantoms (titanium alloy and stainless steel screws), we compared the magnitude of metal-induced artifacts for various pulse sequences, different imaging parameters for the fast spin-echo sequence, and different imaging parameters for several incremental angles between the long axis of the screw and the direction of the main magnetic field. In clinical MR imaging of knees with metallic implants (n = 19), we assessed geometric distortion of anatomic structures to compare the influence of different pulse sequences (n = 19), frequency-encoding directions (n = 7), and knee positions (n = 15). RESULTS, Titanium alloy screws consistently produced smaller artifacts than did stainless steel screws. In experimental MR studies, artifacts were reduced with fast spin-echo sequences, with a screw orientation as closely parallel to the main magnetic field as possible, and, particularly, with smaller voxels that correlated positively with artifact size (R-2 = .88, p < .01). In clinical MR studies, fast spin-echo MR imaging obscured articular structures less than did spin-echo imaging (8/19 patients), In particular, the anterior-posterior frequency-encoding direction (3/7 patients) and the flexion position of the knee (5/15 patients) were effective in reducing artifacts. CONCLUSION. MR artifacts can be minimized by optimally positioning in the magnet subjects with metallic implants and by choosing fast spin-echo sequences with an anterior-posterior frequency-encoding direction and the smallest voxel size.
引用
收藏
页码:1207 / 1213
页数:7
相关论文
共 23 条
[1]   MR IMAGING OF LARGE NONFERROMAGNETIC METALLIC IMPLANTS AT 1.5-T [J].
AUGUSTINY, N ;
VONSCHULTHESS, GK ;
MEIER, D ;
BOSIGER, P .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1987, 11 (04) :678-683
[2]   SIMULATION OF SUSCEPTIBILITY ARTIFACTS IN 2D AND 3D FOURIER-TRANSFORM SPIN-ECHO AND GRADIENT-ECHO MAGNETIC-RESONANCE-IMAGING [J].
BAKKER, CJG ;
BHAGWANDIEN, R ;
MOERLAND, MA ;
RAMOS, LMP .
MAGNETIC RESONANCE IMAGING, 1994, 12 (05) :767-774
[3]   SUSCEPTIBILITY ARTIFACTS IN 2DFT SPIN-ECHO AND GRADIENT-ECHO IMAGING - THE CYLINDER MODEL REVISITED [J].
BAKKER, CJG ;
BHAGWANDIEN, R ;
MOERLAND, MA ;
FUDERER, M .
MAGNETIC RESONANCE IMAGING, 1993, 11 (04) :539-548
[4]   ANALYSIS OF MACHINE-DEPENDENT AND OBJECT-INDUCED GEOMETRIC DISTORTION IN 2DFT MR IMAGING [J].
BAKKER, CJG ;
MOERLAND, MA ;
BHAGWANDIEN, R ;
BEERSMA, R .
MAGNETIC RESONANCE IMAGING, 1992, 10 (04) :597-608
[5]   Magnetic resonance imaging for the determination of magnetic susceptibility of materials [J].
Beuf, O ;
Briguet, A ;
Lissac, M ;
Davis, R .
JOURNAL OF MAGNETIC RESONANCE SERIES B, 1996, 112 (02) :111-118
[6]   NUMERICAL-ANALYSIS OF THE MAGNETIC-FIELD FOR ARBITRARY MAGNETIC-SUSCEPTIBILITY DISTRIBUTIONS IN 2D [J].
BHAGWANDIEN, R ;
VANEE, R ;
BEERSMA, R ;
BAKKER, CJG ;
MOERLAND, MA ;
LAGENDIJK, JJW .
MAGNETIC RESONANCE IMAGING, 1992, 10 (02) :299-313
[7]   REDUCTION OF SUSCEPTIBILITY ARTIFACT IN GRADIENT-ECHO IMAGING [J].
CHO, ZH ;
RO, YM .
MAGNETIC RESONANCE IN MEDICINE, 1992, 23 (01) :193-200
[8]  
EBRAHEIM NA, 1992, CLIN ORTHOP RELAT R, P194
[9]  
EBRAHEIM NA, 1992, CLIN ORTHOP RELAT R, P133
[10]   CAVERNOUS HEMANGIOMAS - DIPOLAR SUSCEPTIBILITY ARTIFACTS AT MR-IMAGING [J].
KIM, JK ;
KUCHARCZYK, W ;
HENKELMAN, RM .
RADIOLOGY, 1993, 187 (03) :735-741