Serial intravascular ultrasound analysis of edge recurrence after intracoronary gamma radiation treatment of native artery in-stent restenosis lesions

被引:14
作者
Ahmed, JM
Mintz, GS
Waksman, R
Lansky, AJ
Mehran, R
Wu, HS
Weissman, NJ
Pichard, AD
Satler, LF
Kent, KM
Leons, MB
机构
[1] Washington Hosp Ctr, Intravasc Ultrasound Imaging Lab, Washington, DC 20010 USA
[2] Washington Hosp Ctr, Cardiac Catheterizat Labs, Washington, DC 20010 USA
[3] Cardiovasc Res Fdn, New York, NY USA
关键词
D O I
10.1016/S0002-9149(01)01483-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
In the Washington Radiation for in-Stent restenosis Trial (WRIST), patients were first treated with conventional techniques and then randomized to either gamma -irradiation (Ir-192) or placebo (dummy seeds). In the Ir-192 group with native coronary in-stent restenosis, we identified 8 patients with edge recurrence and compared them with 21 patients with no recurrence. Serial (postirradiation and follow-up) intravascular ultrasound analysis was performed according to conventional methods. When compared with nonrecurring lesions, lesions with distal edge recurrence had (1) greater decrease in mean distal lumen cross-sectional area (-3.0 +/- 1.2 vs -0.7 +/- 1.0 mm(2), p = 0.0002), (2) no change in mean distal external elastic membrane cross-sectional area versus an increase in mean distal cross-sectional area of 1.0 +/- 0.9 mm(2) in nonrecurring lesions (p = 0.0047), and (3) a greater increase in mean distal plaque + media cross-sectional area (2.9 +/- 1.2 mm vs 1.7 +/- 0.6 mm(2), p = 0.0103). Within the stented segment, the nonrecurring lesions had no decrease in mean lumen and no increase in mean intimal hyperplasia cross-sectional area. Conversely, lesions with distal edge recurrence had a significant decrease in mean intrastent lumen cross-sectional area (-1.7 +/- 1.7 mm(2)) and a significant increase in mean intrastent intimal hyperplasia cross-sectional area (1.6 +/- 1.6 mm(2)). Lesions with distal edge recurrence also had a greater decrease in mean proximal lumen cross-sectional area (-1.7 +/- 1.3 vs -0.3 +/- 0.8 mm(2), p = 0.0213), with a trend toward a greater increase in mean proximal plaque + media cross-sectional area. Thus, edge recurrence after Ir-192 treatment of in-stent restenosis is the result of neointimal hyperplasia (part of generalized treatment failure) and the absence of radiation-induced positive remodeling. (C)2001 by Excerpta Medica, Inc.
引用
收藏
页码:1145 / 1149
页数:5
相关论文
共 11 条
[1]   Safety of intracoronary γ-radiation on uninjured reference segments during the first 6 months after treatment of in-stent restenosis -: A serial intravascular ultrasound study [J].
Ahmed, JM ;
Mintz, GS ;
Waksman, R ;
Weissman, NJ ;
Mehran, R ;
Pichard, AD ;
Satler, LF ;
Kent, KM ;
Leon, MB .
CIRCULATION, 2000, 101 (19) :2227-2230
[2]  
Ahmed JM, 2001, CIRCULATION, V103, P188
[3]   Edge restenosis after implantation of high activity 32P radioactive β-emitting stents [J].
Albiero, R ;
Nishida, T ;
Adamian, M ;
Amato, A ;
Vaghetti, M ;
Corvaja, N ;
Di Mario, C ;
Colombo, A .
CIRCULATION, 2000, 101 (21) :2454-2457
[4]   Short- and intermediate-term results of 32P radioactive β-emitting stent implantation in patients with coronary artery disease -: The Milan dose-response study [J].
Albiero, R ;
Adamian, M ;
Kobayashi, N ;
Amato, A ;
Vaghetti, M ;
Di Mario, C ;
Colombo, A .
CIRCULATION, 2000, 101 (01) :18-26
[5]   Patterns and mechanisms of in-stent restenosis - A serial intravascular ultrasound study [J].
Hoffmann, R ;
Mintz, GS ;
Dussaillant, GR ;
Popma, JJ ;
Pichard, AD ;
Satler, LF ;
Kent, KM ;
Griffin, J ;
Leon, MB .
CIRCULATION, 1996, 94 (06) :1247-1254
[6]  
Lansky A, 1999, TXB INTERVENTIONAL C, P725
[7]  
Mintz GS, 2000, CIRCULATION, V102, P2915
[8]   Geographic miss -: A cause of treatment failure in radio-oncology applied to intracoronary radiation therapy [J].
Sabaté, M ;
Costa, MA ;
Kozuma, K ;
Kay, IP ;
van der Giessen, WJ ;
Coen, VLMA ;
Ligthart, JMR ;
Serrano, P ;
Levendag, PC ;
Serruys, PW .
CIRCULATION, 2000, 101 (21) :2467-2471
[9]   Geometric vascular remodeling after balloon angioplasty and β-radiation therapy -: A three-dimensional intravascular ultrasound study [J].
Sabaté, M ;
Serruys, PW ;
van der Giessen, WJ ;
Ligthart, JMR ;
Coen, VLMA ;
Kay, IP ;
Gijzel, AL ;
Wardeh, AJ ;
den Boer, A ;
Levendag, PC .
CIRCULATION, 1999, 100 (11) :1182-1188
[10]   Catheter-based radiotherapy to inhibit restenosis after coronary stenting [J].
Teirstein, PS ;
Massullo, V ;
Jani, S ;
Popma, JJ ;
Mintz, GS ;
Russo, RJ ;
Schatz, RA ;
Guarneri, EM ;
Steuterman, S ;
Morris, NB ;
Leon, MB ;
Tripuraneni, P .
NEW ENGLAND JOURNAL OF MEDICINE, 1997, 336 (24) :1697-1703