Preliminary results on the determination of ultratrace amounts of cadmium in tea samples using a flow injection on-line solid phase extraction separation and preconcentration technique to couple with a sequential injection hydride generation atomic fluorescence spectrometry

被引:59
作者
Duan, TC
Song, XJ
Jin, D
Li, HF
Xu, JW
Chen, HT [1 ]
机构
[1] Chinese Acad Sci, Changchun Inst Appl Chem, State Key Lab Electroanalyt Chem, Natl Res Ctr Elctroanalyt & Spectroanalyt Chem, Changchun 130022, Peoples R China
[2] Jilin Univ, Fac Chem, Changchun 130026, Peoples R China
[3] Chinese Acad Sci, Changchun Inst Appl Chem, Lab rare Earth Chem & Phys, Changchun 130022, Peoples R China
基金
中国国家自然科学基金;
关键词
Cd; tea sample; AFS; on-line preconcentration and separation; hydride generation; cyanex; 923;
D O I
10.1016/j.talanta.2005.04.017
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work, a method was developed for determination of ultra-trace levels of Cd in tea samples by atomic fluorescence spectrometry (AFS). A flow injection solid phase extraction (FI-SPE) separation and preconcentration technique, to on-line couple with a sequential injection hydride generation (SI-HG) technique is employed in this study. Cd was preconcentrated on the SPE column, which was made from a neutral extractant named Cyanex 923, while other matrix ions or interfering ions were completely or mostly separated off. Conditions for the SPE separation and preconcentration, as well as conditions for the HG technique, were studied. Due to the separation of interfering elements, Cd hydride generation efficiency could be greatly enhanced with the sole presence of Co2+ with a concentration of 200 which is much lower than those in other works previously reported. Interferences on both the Cd separation and preconcentration, and Cd hydride generation (HG) were investigated; it showed that both the separation and preconcentration system, and the HG system had a strong anti - interference ability. The SPE column could be repeatedly used at least 400 times, a R.S.D. of 0.97% was obtained for 6 measurements of Cd with 0.2 mu g L-1 and a correlation coefficiency of 1.0000 was obtained for the measurement of a series of solutions with Cd concentrations from 0.1 to 2 mu g L-1. The method has a low detection limit of 10.8 ng L-1 for a 25 mL solution and was successfully validated by using two tea standard reference materials (GBWO8513 and GBW07605). (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:968 / 974
页数:7
相关论文
共 16 条
[1]  
BINA G, 2001, HYDROMETALLURGY, V61, P65
[2]   Determination of rare and rare earth elements in soils and sediments by ICP-MS using Ti(OH)4-Fe(OH)3 co-precipitation preconcentration [J].
Duan, TC ;
Chen, HT ;
Zeng, XJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2002, 17 (04) :410-413
[3]   Investigations into the generation of Ag, Au, Cd, Co, Cu, Ni, Sn and Zn by vapour generation and their determination by inductively coupled plasma atomic emission spectrometry, together with a mass spectrometric study of volatile species. Determination of Ag, Au, Co, Cu, Ni and Zn in iron [J].
Duan, XC ;
McLaughlin, RL ;
Brindle, ID ;
Conn, A .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2002, 17 (03) :227-231
[4]   DETERMINATION OF CADMIUM IN AQUEOUS SAMPLES BY VAPOR GENERATION WITH SODIUM TETRAETHYLBORATE(III) REAGENT [J].
DULIVO, A ;
CHEN, YW .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1989, 4 (04) :319-322
[5]   Ultratrace determination of lead, cadmium and copper in environmental and biological samples by atomic absorption spectrometry after their separation and preconcentration using octadecyl silica membrane disks modified with a new N-S Schiff base [J].
Ganjali, MR ;
Basiripour, F ;
Shamsipur, M ;
Hashemi, OR ;
Moghimi, A ;
Aghabozorg, H .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2003, 83 (12) :997-1008
[6]   STUDIES ON THE REACTION BETWEEN CADMIUM AND POTASSIUM TETRAHYDROBORATE IN AQUEOUS-SOLUTION AND ITS APPLICATION IN ATOMIC FLUORESCENCE SPECTROMETRY [J].
GUO, XW ;
GUO, XM .
ANALYTICA CHIMICA ACTA, 1995, 310 (02) :377-385
[7]  
GUO XW, 1995, J ANAL ATOM SPECTROM, V10, P987
[8]   Determination of cadmium by flow injection isotope dilution inductively coupled plasma mass spectrometry with vapour generation sample introduction [J].
Hwang, TJ ;
Jiang, SJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (05) :579-584
[9]   Vesicular hydride generation - In situ preconcentration - Electrothermal atomic absorption spectrometry determination of sub-parts-per-billion levels of cadmium [J].
Infante, HG ;
Sanchez, MLF ;
SanzMedel, A .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (11) :1333-1336
[10]   Ultratrace determination of cadmium by atomic absorption spectrometry using hydride generation with in situ preconcentration in a palladium-coated graphite atomizer [J].
Infante, HG ;
Sanchez, MLF ;
SanzMedel, A .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1996, 11 (08) :571-575