Highly sensitive label-free immunosensor for ochratoxin A based on functionalized magnetic nanoparticles and EIS/SPR detection

被引:109
作者
Zamfir, Lucian-Gabriel [1 ]
Geana, Irina [1 ]
Bourigua, Sondes [2 ]
Rotariu, Lucian [1 ]
Bala, Camelia [1 ]
Errachid, Abdelhamid [2 ]
Jaffrezic-Renault, Nicole [2 ]
机构
[1] Univ Bucharest, Dept Analyt Chem, Bucharest 030018, Romania
[2] Univ Lyon 1, Sci Analyt Lab, F-69622 Villeurbanne, France
关键词
Ochratoxin A; Magnetic nanoparticles; Impedimetric; SPR; IMPEDIMETRIC IMMUNOSENSOR; SURFACE; PERFORMANCE; MONOLAYERS;
D O I
10.1016/j.snb.2011.06.069
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A label-free immunosensor for the detection of ochratoxin A (OTA) based on use of magnetic nanoparticles (MNPs) was developed. A gold electrode was modified using bovine serum albumin conjugate with a glutaraldehyde-thiolamine linker, creating a layer that prevents non-specific binding of OTA on gold. The OTA antibodies were attached to MNPs using the carbodiimide chemistry and afterwards were immobilized on the modified gold electrode using a strong magnetic field. Cyclic voltammetry (CV). electrochemical impedance spectroscopy (EIS) and surface plasmon resonance (SPR) were used to characterize each step in immunosensor development. The impedance variation due to the specific antibody-OTA interaction was correlated with the OTA concentration in the samples. The increase in electron-transfer resistance values was proportional to the concentration of OTA on a linear range between 0.01 and 5 ng/mL, with a detection limit of 0.01 ng/mL. SPR measurements showed a larger response range (1-50 ng/mL) with a detection limit of 0.94 ng/ml.. Analytical results were in accordance with standard ELISA test kit. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:178 / 184
页数:7
相关论文
共 27 条
[1]   Development of immunosensor based on OWLS technique for determining Aflatoxin B1 and Ochratoxin A [J].
Adanyi, N. ;
Levkovets, I. A. ;
Rodriguez-Gil, S. ;
Ronald, A. ;
Varadi, M. ;
Szendro, I. .
BIOSENSORS & BIOELECTRONICS, 2007, 22 (06) :797-802
[2]   Adsorption of ochratoxin A (OTA) anodic oxidation product on glassy carbon electrodes in highly acidic reaction media: Its thermodynamic and kinetics characterization [J].
Alejandro Ramirez, Eduardo ;
Alicia Zon, Maria ;
Jara Ulloa, Paola Andrea ;
Arturo Squella, Juan ;
Nunez Vergara, Luis ;
Fernandez, Hector .
ELECTROCHIMICA ACTA, 2010, 55 (03) :771-778
[3]   Building of an immunosensor:: How can the composition and structure of the thiol attachment layer affect the immunosensor efficiency? [J].
Briand, Elisabeth ;
Salmain, Michele ;
Herry, Jean-Marie ;
Perrot, Hubert ;
Compere, Chantal ;
Pradier, Claire-Marie .
BIOSENSORS & BIOELECTRONICS, 2006, 22 (03) :440-448
[4]   Strategies for electrochemical detection in immunochemistry [J].
Centi, Sonia ;
Laschi, Serena ;
Mascini, Marco .
BIOANALYSIS, 2009, 1 (07) :1271-1291
[5]   Modified magnetic nanoparticles in an electrochemical method for the ochratoxin A determination in Vitis vinifera red grapes tissues [J].
Fernandez-Baldo, Martin A. ;
Bertolino, Franco A. ;
Messina, German A. ;
Sanz, Maria I. ;
Raba, Julio .
TALANTA, 2010, 83 (02) :651-657
[6]   Enhanced performance of an affinity biosensor interface based on mixed self-assembled monolayers of thiols on gold [J].
Frederix, F ;
Bonroy, K ;
Laureyn, W ;
Reekmans, G ;
Campitelli, A ;
Dehaen, W ;
Maes, G .
LANGMUIR, 2003, 19 (10) :4351-4357
[7]   Surface plasmon resonance immunoassay for ochratoxin a based on nanogold hollow balls with dendritic surface [J].
Fu, Xiao-Hong .
ANALYTICAL LETTERS, 2007, 40 (14) :2641-2652
[8]   Investigation of solvent effect and cyclodextrins on fluorescence properties of ochratoxin A [J].
Hashemi, Javad ;
Alizadeh, Naader .
SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2009, 73 (01) :121-126
[9]   Under flow impedimetric measurements using magnetic particles for label-free detection affinity target [J].
Hassen, Walid Mohamed ;
Angnes, Lucio ;
Abdelghani, Adnane ;
Bessueille, Francois ;
Leonard, Didier ;
Jaffrezic-Renault, Nicole .
MATERIALS SCIENCE & ENGINEERING C-BIOMIMETIC AND SUPRAMOLECULAR SYSTEMS, 2008, 28 (5-6) :820-825
[10]   Chitosan/polyaniline hybrid conducting biopolymer base impedimetric immunosensor to detect Ochratoxin-A [J].
Khan, Raju ;
Dhayal, Marshal .
BIOSENSORS & BIOELECTRONICS, 2009, 24 (06) :1700-1705