The use of radiofrequency glow discharge-mass spectrometry (rf-GD-MS) coupled to gas chromatography for the determination of selenoaminoacids in biological samples

被引:25
作者
Bayón, MM [1 ]
B'Hymer, C [1 ]
de León, CAP [1 ]
Caruso, JA [1 ]
机构
[1] Univ Cincinnati, Dept Chem, Cincinnati, OH 45221 USA
关键词
D O I
10.1039/b100072l
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A radiofrequency glow discharge (rf-GD) has been used as an ion source for mass spectrometry using gas chromatography as the sample introduction technique for the speciation of seleno amino acids. The use of helium as the plasma gas allowed the monitoring of selenium's major isotope (Se-80), interfered by polyatomic species when using Ar as the plasma gas. Optimization of the power and pressure of the source was undertaken to achieve the best sensitivity for selenium determination and detection limits of about 100 pg (as Se) have been obtained for the derivatized Se-methionine. Studying the cell pressure and power on the fragmentation patterns obtained for Se-methionine and Se-ethionine has also been undertaken to characterize the source. No significant variations were observed on the mass spectra under different operating conditions, although noticeable variation of the fragment intensities was observed. The system has been applied to the determination of Se-methionine in selenium-enriched yeast after enzymatic extraction of the corresponding species using Proteinase K to cleave the peptide bonds. The results obtained showed a Se-methionine content of about 78% in the enriched yeast.
引用
收藏
页码:492 / 497
页数:6
相关论文
共 25 条
[21]   Development of chiral HPLC for selenoamino acids with ICP-MS detection: application to selenium nutritional supplements [J].
Sutton, KL ;
de Leon, CAP ;
Ackley, KL ;
Sutton, RMC ;
Stalcup, AM ;
Caruso, JA .
ANALYST, 2000, 125 (02) :281-286
[22]   A comparison of different derivatisation approaches for the determination of selenomethionine by GC-ICP-MS [J].
Peláez, MV ;
Bayón, MM ;
Alonso, JIGA ;
Sanz-Medel, A .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2000, 15 (09) :1217-1222
[23]  
Velado NGO, 2000, J ANAL ATOM SPECTROM, V15, P49
[24]   Application of a low power/reduced pressure helium ICP ionization source for mass spectrometric detection of organobromine compounds and derivatized organotin compounds [J].
Waggoner, JW ;
Milstein, LS ;
Belkin, M ;
Sutton, KL ;
Caruso, JA ;
Fannin, HB .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2000, 15 (01) :13-18
[25]   Novel low power reduced pressure inductively coupled plasma ionization source for mass spectrometric detection of organotin species [J].
Waggoner, JW ;
Belkin, M ;
Sutton, KL ;
Caruso, JA ;
Fannin, HB .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1998, 13 (09) :879-883