Application of a low power/reduced pressure helium ICP ionization source for mass spectrometric detection of organobromine compounds and derivatized organotin compounds

被引:27
作者
Waggoner, JW
Milstein, LS
Belkin, M
Sutton, KL
Caruso, JA [1 ]
Fannin, HB
机构
[1] Univ Cincinnati, Dept Chem, Cincinnati, OH 45221 USA
[2] Murray State Univ, Dept Chem, Murray, KY 42071 USA
关键词
D O I
10.1039/a905906g
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A low power, reduced pressure helium inductively coupled plasma source for mass spectrometry with capillary gas chromatography was applied to the detection of the organobromine species bromobenzene, 1-bromoheptane and benzyl bromide and ethylated forms of the ionic tri-substituted organotin species tributyltin chloride (TBuSnCl) and tripropyltin chloride (TPrSnCl). Total elemental information obtained with plasma source ionization was augmented with a capability to take fragment spectra that provides structural information about gas chromatographic eluents. Limits of detection for bromobenzene, 1-bromoheptane and benzyl bromide were 11, 6 and 4 pg, respectively. Molecular ions for all three organobromine compounds were obtained, as well as some characteristic alkyl chain fragments for 1-bromoheptane, resembling an electron impact mass spectrum. The ethyl, propyl and butyl substituents of ethylated TBuSnCl and TPrSnCl were clearly identified as fragments in the mass spectra. Chromatographic retention time and mass spectral matches with ethylated organotin standards were obtained for the TBuSnCl component of the certified reference material NIES-11.
引用
收藏
页码:13 / 18
页数:6
相关论文
共 22 条
[1]   The potential of a modified rf glow discharge source for enhanced elemental speciation studies [J].
Belkin, M ;
Waggoner, JW ;
Caruso, JA .
ANALYTICAL COMMUNICATIONS, 1998, 35 (09) :281-283
[2]   Radiofrequency glow discharge as an ion source for gas chromatography with mass spectrometric detection [J].
Belkin, MA ;
Olson, LK ;
Caruso, JA .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (11) :1255-1261
[3]   Microplasma mass spectrometric detection in capillary gas chromatography [J].
Brede, C ;
Pedersen-Bjergaard, S ;
Lundanes, E ;
Greibrokk, T .
ANALYTICAL CHEMISTRY, 1998, 70 (03) :513-518
[4]   EVALUATION OF LOW-PRESSURE INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY FOR THE ANALYSIS OF GASEOUS SAMPLES [J].
CASTILLANO, TM ;
GIGLIO, JJ ;
EVANS, EH ;
CARUSO, JA .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1994, 9 (12) :1335-1340
[5]   Determination of organometallic compounds in surface water and sediment samples with SPME-CGC-ICPMS [J].
De Smaele, T ;
Moens, L ;
Sandra, P ;
Dams, R .
MIKROCHIMICA ACTA, 1999, 130 (04) :241-251
[6]   In situ ethylation-purge and programmed-temperature-vaporizer cold trapping gas chromatography mass spectrometry as an automated technique for the determination of methyl- and butyltin compounds in aqueous samples [J].
Eiden, R ;
Schöler, HF ;
Gastner, M .
JOURNAL OF CHROMATOGRAPHY A, 1998, 809 (1-2) :151-157
[7]   LOW-PRESSURE INDUCTIVELY-COUPLED PLASMA ION-SOURCE FOR MOLECULAR AND ATOMIC MASS-SPECTROMETRY [J].
EVANS, EH ;
PRETORIUS, W ;
EBDON, L ;
ROWLAND, S .
ANALYTICAL CHEMISTRY, 1994, 66 (20) :3400-3407
[8]   Complementary use of capillary gas chromatography mass spectrometry (ion trap) and gas chromatography inductively coupled plasma mass spectrometry for the speciation of volatile antimony, tin and bismuth compounds in landfill and fermentation gases [J].
Feldmann, J ;
Koch, I ;
Cullen, WR .
ANALYST, 1998, 123 (05) :815-820
[9]  
Garcia ES, 1997, J MASS SPECTROM, V32, P542
[10]   Solid phase microextraction as sample introduction technique for radio frequency glow discharge mass spectrometry [J].
Gorecki, T ;
Belkin, M ;
Caruso, J ;
Pawliszyn, J .
ANALYTICAL COMMUNICATIONS, 1997, 34 (10) :275-277