A fast, effective method of characterizing new phase systems in CCC

被引:13
作者
Ignatova, SN
Sutherland, IA [1 ]
机构
[1] Brunel Univ, Brunel Inst Bioengn, Uxbridge UB8 3PH, Middx, England
[2] Russian Acad Sci, Vernadsky Inst Geochem & Analyt Chem, Moscow, Russia
关键词
countercurrent chromatography; liquid stationary phase retention; fundamental theory; resolution; flow rate;
D O I
10.1081/JLC-120021266
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This paper describes two simple tests that will characterize the hydrodynamics of a given phase system in a given CCC unit. Furthermore, it shows that, in practice, only one of these tests is necessary and the other can be predicted from the first. It goes on to show that retention information can be accurately obtained using a marker peak for the solvent front, so that both retention and resolution data can be collected in one simple test. While stationary phase retention (and, hence, peak elution) was found to behave quite predictably and could be modelled, resolution was not so predictable. Nevertheless, for analytical CCC, it was found that resolution of benzyl alcohol (BA) and p-cresol (PC) only reduced from 2.3 to 1.4 as flow increased 7-fold from 0.3 mL/min to 2 mL/min. Increasing the speed from 1000 to 2000 rpm (a 4x increase in "g" field) only increased the resolution a factor of 1.4x, whereas it was expected (from the number of mixing/settling cycles) to double. It is concluded that, for fast analytical CCC, it is worth running at as high a flow as possible (compensating for loss of resolution by increasing coil length) and increase speed only if it becomes necessary to obtain a reasonable retention.
引用
收藏
页码:1551 / 1564
页数:14
相关论文
共 6 条
[1]   Separation of epigallocatechin gallate and gallocatechin gallate using multiple instruments connected in series [J].
Du, QZ ;
Ke, CQ ;
Ito, Y .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 1998, 21 (1-2) :203-208
[2]   Relationship between the flow-rate of the mobile phase and retention of the stationary phase in counter-current chromatography [J].
Du, QZ ;
Wu, CJ ;
Qian, GJ ;
Wu, PD ;
Ito, Y .
JOURNAL OF CHROMATOGRAPHY A, 1999, 835 (1-2) :231-235
[3]  
ITO Y, 1986, CRIT REV ANAL CHEM, V17, P65, DOI 10.1080/10408348608542792
[4]   A new small coil-volume CCC instrument for direct interfacing with MS [J].
Janaway, L ;
Hawes, D ;
Ignatova, S ;
Wood, P ;
Sutherland, IA .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2003, 26 (9-10) :1345-1354
[5]  
Wood P. L., 2002, THESIS BRUNEL U
[6]   Stationary phase retention in CCC: Modelling the J-type centrifuge as a constant pressure drop pump [J].
Wood, PL ;
Hawes, D ;
Janaway, L ;
Sutherland, IA .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2003, 26 (9-10) :1373-1396