Differential phase contrast in optical coherence tomography

被引:59
作者
Hitzenberger, CK [1 ]
Fercher, AF [1 ]
机构
[1] Univ Vienna, Inst Med Phys, A-1090 Vienna, Austria
关键词
D O I
10.1364/OL.24.000622
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We report on a modification of optical coherence tomography. (OCT) that allows one to measure small phase differences between beams traversing adjacent areas of a specimen. The sample beam of a polarization-sensitive low-coherence interferometer is split by a Wollaston prism into two components that traverse the object along closely spaced paths. After reflection at the various sample surfaces, the beams are recombined at the Wollaston prism. Any phase difference encountered between the two beams is converted into a change of polarization state of the recombined beam. This change is measured, and the resulting signals are converted to differential phase-contrast OCT images. The first images obtained from simple test objects allowed us to determine path-difference gradients with a resolution of the order of 5 x 10(-5). (C) 1999 Optical Society of America.
引用
收藏
页码:622 / 624
页数:3
相关论文
共 10 条
[1]   SIGNAL AND RESOLUTION ENHANCEMENTS IN DUAL BEAM OPTICAL COHERENCE TOMOGRAPHY OF THE HUMAN EYE [J].
Baumgartner, Angela ;
Hitzenberger, Christoph K. ;
Sattmann, Harald ;
Drexler, Wolfgang ;
Fercher, Adolf F. .
JOURNAL OF BIOMEDICAL OPTICS, 1998, 3 (01) :45-54
[2]   Full-field optical coherence microscopy [J].
Beaurepaire, E ;
Boccara, AC ;
Lebec, M ;
Blanchot, L ;
Saint-Jalmes, H .
OPTICS LETTERS, 1998, 23 (04) :244-246
[3]   Two-dimensional birefringence imaging in biological tissue by polarization-sensitive optical coherence tomography [J].
deBoer, JF ;
Milner, TE ;
vanGemert, MJC ;
Nelson, JS .
OPTICS LETTERS, 1997, 22 (12) :934-936
[4]   Birefringence characterization of biological tissue by use of optical coherence tomography [J].
Everett, MJ ;
Schoenenberger, K ;
Colston, BW ;
Da Silva, LB .
OPTICS LETTERS, 1998, 23 (03) :228-230
[5]  
Fercher A F, 1996, J Biomed Opt, V1, P157, DOI 10.1117/12.231361
[6]   POLARIZATION-SENSITIVE LOW-COHERENCE REFLECTOMETER FOR BIREFRINGENCE CHARACTERIZATION AND RANGING [J].
HEE, MR ;
HUANG, D ;
SWANSON, EA ;
FUJIMOTO, JG .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS, 1992, 9 (06) :903-908
[7]   OPTICAL COHERENCE TOMOGRAPHY [J].
HUANG, D ;
SWANSON, EA ;
LIN, CP ;
SCHUMAN, JS ;
STINSON, WG ;
CHANG, W ;
HEE, MR ;
FLOTTE, T ;
GREGORY, K ;
PULIAFITO, CA ;
FUJIMOTO, JG .
SCIENCE, 1991, 254 (5035) :1178-1181
[8]   OPTICAL COHERENCE MICROSCOPY IN SCATTERING MEDIA [J].
IZATT, JA ;
HEE, MR ;
OWEN, GM ;
SWANSON, EA ;
FUJIMOTO, JG .
OPTICS LETTERS, 1994, 19 (08) :590-592
[9]   An optical coherence microscope with enhanced resolving power in thick tissue [J].
Schmitt, JM ;
Lee, SL ;
Yung, KM .
OPTICS COMMUNICATIONS, 1997, 142 (4-6) :203-207
[10]   IN-VIVO RETINAL IMAGING BY OPTICAL COHERENCE TOMOGRAPHY [J].
SWANSON, EA ;
IZATT, JA ;
HEE, MR ;
HUANG, D ;
LIN, CP ;
SCHUMAN, JS ;
PULIAFITO, CA ;
FUJIMOTO, JG .
OPTICS LETTERS, 1993, 18 (21) :1864-1866