The characterization of a commercial MOSFET dosimeter system for use in diagnostic x ray

被引:50
作者
Bower, MW
Hintenlang, DE
机构
[1] Univ Florida, Dept Nucl & Radiol Sci, Gainesville, FL 32611 USA
[2] USA, Med Dept Ctr, Gainesville, FL 32611 USA
[3] Univ Florida, Sch Duty, Gainesville, FL 32611 USA
来源
HEALTH PHYSICS | 1998年 / 75卷 / 02期
关键词
x rays; diagnostic radiology; dose; absorbed; medical radiation;
D O I
10.1097/00004032-199808000-00013
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A commercial patient dose verification system utilizing non-invasive metal oxide semiconductor field effect transistor (MOSFET) dosimeters originally designed for radiotherapy applications has been evaluated for use at diagnostic energy levels. The system features multiple dosimeters that may be used to monitor entrance or exit skin dose and intracavity doses in phantoms in real time. We have characterized both the standard MOSFET dosimeter designed for radiotherapy dose verification and a newly developed "high sensitivity" MOSFET dosimeter designed for lower dose measurements. The sensitivity, linearity, angular response, postexposure response, and physical characteristics were evaluated. The average sensitivity (free in air, including backscatter) of the radiotherapy MOSFET dosimeters ranged from 3.55 x 10(4) mV per C kg(-1) (9.2 mV R-1) to 4.87 x 10(4) mV per C kg(-1) (12.6 mV R-1) depending on the energy of the x-ray field. The sensitivity of the "high sensitivity" MOSFET dosimeters ranged from 1.15 x 10(5) mV per C kg(-1) (29.7 mV R-1) to 1.38 x 10(5) mV per C kg(-1) (35.7 mV R-1) depending on the energy of the x-ray field, The high sensitivity dosimeters demonstrated excellent linearity at high energies (90 and 120 kVp) and acceptable linearity at lower energies (60 kVp), The angular response was significant for free-in-air exposures, as illustrated by the sensitivity differences between the two sides of the dosimeter, but was excellent for measurements within a tissue equivalent cylinder. The post-exposure drift response is a complicated but reproducible function of time. Real-time monitoring requires little if any corrections for the postexposure drift response. The MOSFET dosimeter system brings some unique capabilities to diagnostic radiology dosimetry including small size, real-time capabilities, nondestructive measurement, good linearity, and a predictable angular response.
引用
收藏
页码:197 / 204
页数:8
相关论文
共 17 条
[1]  
*BUR RAD HLTH, 1979, QUANT CURR PRACT MED
[2]   A new radiotherapy surface dose detector: The MOSFET [J].
Butson, MJ ;
Rozenfeld, A ;
Mathur, JN ;
Carolan, M ;
Wong, TPY ;
Metcalfe, PE .
MEDICAL PHYSICS, 1996, 23 (05) :655-658
[3]  
Fleetwood DM, 1996, IEEE T NUCL SCI, V43, P779, DOI 10.1109/23.510713
[4]  
Food and Drug Administration (FDA), 1994, AV SER XRAY IND SKIN
[5]  
GESSINN F, 1993, MATER RES SOC SYMP P, V302, P555, DOI 10.1557/PROC-302-555
[6]   REAL-TIME, IN-VIVO MEASUREMENT OF RADIATION-DOSE DURING RADIOIMMUNOTHERAPY IN MICE USING A MINIATURE MOSFET DOSIMETER PROBE [J].
GLADSTONE, DJ ;
CHIN, LM .
RADIATION RESEARCH, 1995, 141 (03) :330-335
[7]   A MINIATURE MOSFET RADIATION DOSIMETER PROBE [J].
GLADSTONE, DJ ;
LU, XQ ;
HUMM, JL ;
BOWMAN, HF ;
CHI, LM .
MEDICAL PHYSICS, 1994, 21 (11) :1721-1728
[8]   AUTOMATED DATA-COLLECTION AND ANALYSIS SYSTEM FOR MOSFET RADIATION DETECTORS [J].
GLADSTONE, DJ ;
CHIN, LM .
MEDICAL PHYSICS, 1991, 18 (03) :542-548
[9]   THE MECHANISMS OF SMALL INSTABILITIES IN IRRADIATED MOS-TRANSISTORS [J].
HOLMESSIEDLE, A ;
ADAMS, L .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1983, 30 (06) :4135-4140
[10]   MINIATURE RADIATION DOSIMETER FOR INVIVO RADIATION MEASUREMENTS [J].
HUGHES, RC ;
HUFFMAN, D ;
SNELLING, JV ;
ZIPPERIAN, TE ;
RICCO, AJ ;
KELSEY, CA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1988, 14 (05) :963-967