A MINIATURE MOSFET RADIATION DOSIMETER PROBE

被引:49
作者
GLADSTONE, DJ [1 ]
LU, XQ [1 ]
HUMM, JL [1 ]
BOWMAN, HF [1 ]
CHI, LM [1 ]
机构
[1] THERMAL TECHNOL INC,CAMBRIDGE,MA 02139
关键词
MOSFET; RADFET; MINIATURE DOSIMETER; IN VIVO; DOSIMETRY; RADIOIMMUNOTHERAPY;
D O I
10.1118/1.597214
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Prototype miniature dosimeter probes have been designed, built, and characterized employing a small, radiation sensitive metal oxide semiconductor field effect transistor (MOSFET) chip to measure, in vivo, the total accumulated dose and dose rate as a function of time after internal administration of long range beta particle radiolabeled antibodies and in external high energy photon and electron beams. The MOSFET detector is mounted on a long narrow alumina substrate to facilitate electrical connection. The MOSFET, alumina substrate, and lead wires are inserted into a 16 gauge fiexineedle, which, in turn, may be inserted into tissue. The radiation dosimeter probe has overall dimensions of 1.6 mm diam and 3.5 cm length. The MOSFET probe signals are read, stored, and analyzed using an automated data collection and analysis system. Initially, we have characterized the probe's response to long range beta particle emission from 90Y sources in solution and to high energy photon and electron beams from linear accelerators. Since the prototype has a finite substrate thickness, the angular dependence has been studied using beta particle emission from a 90Sr source. Temperature dependence and signal drift have been characterized and may be corrected for. Measurements made in spherical volumes containing 90Y with diameters less than the maximum electron range, to simulate anticipated geometries in animal models, agree well with Berger point kernel and EGS4 Monte Carlo calculations. The results from the prototype probes lead to design requirements for detection of shorter range beta particles used in radioimmunotherapy and lower photon energies used in brachytherapy. © 1994, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:1721 / 1728
页数:8
相关论文
共 30 条
[1]   DESIGN CRITERIA FOR A HIGH-DOSE MOS DOSIMETER FOR USE IN SPACE [J].
AUGUST, LS .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1984, 31 (01) :801-803
[2]  
BERGER MJ, 1971, MIRD7 SOC NUCL MED I
[3]   ELECTRON-HOLE RECOMBINATION IN IRRADIATED SIO2 FROM A MICRODOSIMETRY VIEWPOINT [J].
BROWN, DB ;
DOZIER, CM .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1981, 28 (06) :4142-4144
[4]   CMOS HARDNESS PREDICTION FOR LOW-DOSE-RATE ENVIRONMENTS [J].
DERBENWICK, GF ;
SANDER, HH .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1977, 24 (06) :2244-2247
[5]   EFFECT OF PHOTON ENERGY ON THE RESPONSE OF MOS DEVICES [J].
DOZIER, CM ;
BROWN, DB .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1981, 28 (06) :4137-4141
[6]  
GLADSTONE DJ, 1991, MED PHYS, V18, P3
[7]  
GRIFFITH MH, 1988, J NUCL MED, V29, P1795
[8]   SPACE-CHARGE DOSIMETER - GENERAL PRINCIPLES OF A NEW METHOD OF RADIATION DETECTION [J].
HOLMESSI.A .
NUCLEAR INSTRUMENTS & METHODS, 1974, 121 (01) :169-179
[9]   THE MECHANISMS OF SMALL INSTABILITIES IN IRRADIATED MOS-TRANSISTORS [J].
HOLMESSIEDLE, A ;
ADAMS, L .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1983, 30 (06) :4135-4140
[10]  
HOLMESSIEDLE A, COMMUNICATION