Unlimited-volume stacking of ions in capillary electrophoresis. Part 1: Stationary isotachophoretic stacking of anions

被引:43
作者
Breadmore, Michael C. [1 ]
机构
[1] Univ Tasmania, Sch Chem, Australian Ctr Res Separat Sci, Hobart, Tas 7001, Australia
关键词
inorganic anions; isotachophoresis; preconcentration; unlimited stacking;
D O I
10.1002/elps.200700728
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An online technique for stacking based on the generation of a stationary isotachophoretic (sITP) boundary is presented. By balancing the anodic migration of an ITP boundary with a cathodic EOF, a stationary boundary is formed that can be used to indefinitely concentrate analytes according to ITP principles during electrokinetic injection. The ITP boundary is created by using an electrolyte containing a leading ion (chloride) and a suitable terminating ion added to the sample (2-morpholinoethanesulphonic acid, MES). Destacking and separation are achieved simply by replacement of the sample vial with electrolyte. The formation and stabilisation of the sITP boundary were evaluated through computer simulation which revealed that the pH had little impact upon the formation of the sITP boundary, but did govern the position at which it becomes stationary. Simulations also demonstrated that similar results were obtained when the capillary was initially fined with sample/terminator or leader/electrolyte, which was also supported by experimental results. Using 100 mM Cl-, 200 mM Tris, pH 8.05 as the leader/electrolyte and adding 100 mM MES, 200 mM Tris, pH 8.05 to the sample, the sITP boundary was established after 5 min at -20 kV and was stable for at least 60 min. This provided detection limits for NO2-, NO3- and SCN- of 0.05-0.66 ppb, which are 10000 times lower than hydrodynamic injection and 10-50 times lower than other stacking approaches used for these inorganic ions.
引用
收藏
页码:1082 / 1091
页数:10
相关论文
共 48 条
[1]   ANALYSIS OF DILUTE PEPTIDE SAMPLES BY CAPILLARY ZONE ELECTROPHORESIS [J].
AEBERSOLD, R ;
MORRISON, HD .
JOURNAL OF CHROMATOGRAPHY, 1990, 516 (01) :79-88
[2]   Potential of on-line isotachophoresis-capillary zone electrophoresis with hydrodynamic counterflow in the analysis of various basic proteins and recombinant human interleukin-3 [J].
Bergmann, J ;
Jaehde, U ;
Mazereeuw, M ;
Tjaden, UR ;
Schunack, W .
JOURNAL OF CHROMATOGRAPHY A, 1996, 734 (02) :381-389
[3]   Quantitative trace analysis of interleukin-3, interleukin-6, and basic model proteins using isotachophoresis-capillary zone electrophoresis with hydrodynamic counterflow [J].
Bergmann, J ;
Jaehde, U ;
Schunack, W .
ELECTROPHORESIS, 1998, 19 (02) :305-310
[4]   ELECTROPHORESIS - MATHEMATICAL-MODELING AND COMPUTER-SIMULATION [J].
BIER, M ;
PALUSINSKI, OA ;
MOSHER, RA ;
SAVILLE, DA .
SCIENCE, 1983, 219 (4590) :1281-1287
[5]   High-resolution computer simulations of stacking of weak bases using a transient pH boundary in capillary electrophoresis. 1. Concept and impact of sample ionic strength [J].
Breadmore, MC ;
Mosher, RA ;
Thormann, W .
ANALYTICAL CHEMISTRY, 2006, 78 (02) :538-546
[6]   On capillary ion-exchange preconcentration of inorganic anions in open-tubular capillary electrochromatography with elution using transient-isotachophoretic gradients. 2. Characterization of the isotachophoretic gradient [J].
Breadmore, MC ;
Macka, M ;
Avdalovic, N ;
Haddad, PR .
ANALYTICAL CHEMISTRY, 2001, 73 (04) :820-828
[7]   Recent advances in enhancing the sensitivity of electrophoresis and electrochromatography in capillaries and microchips [J].
Breadmore, Michael C. .
ELECTROPHORESIS, 2007, 28 (1-2) :254-281
[8]   Quantitative assay fdr epinephrine in dental anesthetic solutions by capillary electrophoresis [J].
Britz-Mckibbin, P ;
Kranack, AR ;
Paprica, A ;
Chen, DDY .
ANALYST, 1998, 123 (07) :1461-1463
[9]   IMPROVEMENT IN THE METHOD OF SAMPLE STACKING FOR GRAVITY INJECTION IN CAPILLARY ZONE ELECTROPHORESIS [J].
BURGI, DS ;
CHIEN, RL .
ANALYTICAL BIOCHEMISTRY, 1992, 202 (02) :306-309
[10]   The combination of flow injection with electrophoresis using capillaries and chips [J].
Chen, XG ;
Fan, LY ;
Hu, Z .
ELECTROPHORESIS, 2004, 25 (23-24) :3962-3969