Simultaneous determination of inorganic anions and metal ions by suppressed ion chromatography

被引:28
作者
Bruzzoniti, MC [1 ]
Mentasti, E [1 ]
Sarzanini, C [1 ]
机构
[1] Univ Turin, Dept Analyt Chem, I-10125 Turin, Italy
关键词
anions; metal ions; ion chromatography; river water;
D O I
10.1016/S0003-2670(98)00801-0
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work the simultaneous determination of environmentally interesting inorganic anions (BrO3-, SeO32-, SeO42-, HAsO42-, WO42-, MoO42-, CrO42-) and metal ions (Pb2+, Cd2+, Ni2+, Cu2+) precomplexed by EDTA. by suppressed ion chromatography has been optimized. Throughout the work, a latex-based strong anion-exchange resin and carbonate buffer as eluent have been used. The study was performed in presence of anions that commonly occur in real samples (Cl-, NO3-, SO42-). Separation has been optimized studying the main eluent parameters that influence analyte retention, that is carbonate concentration and pH. The method developed has been applied to the determination of the species present in a water sample of the river Po (Turin, Italy). In order to reduce analysis time, the effect of carbonate concentration and pH gradient elutions have been studied. The gradient elution allowed us shorter chromatographic runs without the baseline drift that usually arises during gradient elutions. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:291 / 299
页数:9
相关论文
共 35 条
[1]   LEAD SPECIATION BY HPLC-ICP-AES AND HPLC-ICP-MS [J].
ALRASHDAN, A ;
HEITKEMPER, D ;
CARUSO, JA .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1991, 29 (03) :98-102
[2]   Sequential multielement analysis of Cd, Cr, Hi, and Pb in human tissues by inductively coupled plasma spectrometry [J].
AlSaleh, IA ;
AlDoush, I .
BULLETIN OF ENVIRONMENTAL CONTAMINATION AND TOXICOLOGY, 1996, 57 (04) :511-516
[3]   DETERMINATION OF DISSOLVED INORGANIC SELENIUM(IV) AND SELENIUM(VI) SPECIES IN NATURAL-WATERS BY HYDRIDE GENERATION ATOMIC-ABSORPTION SPECTROMETRY [J].
APTE, SC ;
HOWARD, AG .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1986, 1 (05) :379-382
[4]   Determination of trace amounts of molybdenum in water samples by graphite furnace atomic absorption spectrometry with multiple injections and cool down step [J].
Baralkiewicz, D ;
Siepak, J .
ANALYTICA CHIMICA ACTA, 1997, 353 (01) :85-89
[5]   Trace analysis of bromate and bromide with ion chromatography on coated reversed phase materials [J].
Bohme, U ;
Schmidt, W ;
Dietrich, PG ;
Matschi, A ;
Sacher, F ;
Brauch, HJ .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1997, 357 (06) :629-634
[6]   Determination of copper, lead and cadmium in whole blood by stripping voltammetry with the use of graphite electrodes [J].
Brainina, K ;
Schafer, H ;
Ivanova, A ;
Khanina, R .
ANALYTICA CHIMICA ACTA, 1996, 330 (2-3) :175-181
[7]   Flow injection on-line coprecipitation-preconcentration system using copper(II) diethyldithiocarbamate as carrier for flame atomic absorption spectrometric determination of cadmium, lead and nickel in environmental samples [J].
Chen, HW ;
Jin, JC ;
Wang, YF .
ANALYTICA CHIMICA ACTA, 1997, 353 (2-3) :181-188
[8]   Determination of molybdenum and uranium in biological materials by radiochemical neutron activation analysis [J].
Danko, B ;
Dybczynski, R .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 1997, 216 (01) :51-57
[9]  
GOUGH LP, 1979, US GEOL SURV B, V1466, P42
[10]   SIMULTANEOUS DETERMINATION OF ARSENITE, ARSENATE, SELENITE AND SELENATE IN WATERS USING SUPPRESSED ION CHROMATOGRAPHY WITH ULTRAVIOLET ABSORBENCY DETECTION [J].
GOYAL, SS ;
HAFEZ, A ;
RAINS, DW .
JOURNAL OF CHROMATOGRAPHY, 1991, 537 (1-2) :269-276