Photon-counting versus an integrating CCD-based gamma camera: important consequences for spatial resolution

被引:51
作者
Beekman, FJ
de Vree, GA
机构
[1] Univ Utrecht, Ctr Med, Image Sci Inst, Dept Nucl Med, NL-3584 CG Utrecht, Netherlands
[2] Univ Utrecht, Ctr Med, Rudolf Magnus Inst Neurosci, Dept Pharmacol & Anat, NL-3584 CG Utrecht, Netherlands
关键词
D O I
10.1088/0031-9155/50/12/N01
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Charge-coupled devices (CCDs) coupled to scintillation crystals can be used for high resolution imaging with x-rays and gamma-rays. When the CCD images can be read out fast enough, the energy and interaction position of individual gamma quanta can be estimated by real-time image analysis of scintillation light flashes ('photon counting mode'). We tested a set-up in which an electron-multiplying CCD was coupled to a 1 mm thick columnar CsI crystal by means of a fibre-optic taper. We found that, compared to light integration, photon counting improves the intrinsic spatial resolution by a factor of about 3 to 6. Applying our set-up to Tc-99m and I-125 imaging, we were able to obtain intrinsic resolutions below 60 mu m (full width at half maximum). Counting losses due to overlapping of light flashes are negligible for event rates typical for biomedical radio-nuclide imaging and do strongly depend on energy window settings. Energy resolution was estimated to be approximately 35 keV FWHM for a 1:1 taper. We conclude that CCD-based gamma cameras have great potential for applications such as in vivo imaging of gamma emitters.
引用
收藏
页码:N109 / N119
页数:11
相关论文
共 20 条
[11]   The high resolution gamma imager (HRGI): a CCD based camera for medical imaging [J].
Lees, JE ;
Fraser, GW ;
Keay, A ;
Bassford, D ;
Ott, R ;
Ryder, W .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 513 (1-2) :23-26
[12]   CdZnTe arrays for astrophysics applications [J].
Matteson, JL ;
Coburn, W ;
Duttweiler, F ;
Heindl, WA ;
Huszar, GL ;
Leblanc, PC ;
Pelling, MR ;
Peterson, LE ;
Rothschild, RE ;
Skelton, RT .
HARD X-RAY AND GAMMA-RAY DETECTOR PHYSICS, OPTICS, AND APPLICATIONS, 1997, 3115 :160-175
[13]   POCI:: A compact high resolution γ camera for intra-operative surgical use [J].
Menard, L ;
Charon, Y ;
Solal, M ;
Laniece, P ;
Mastrippolito, R ;
Pinot, L ;
Ploux, L ;
Ricard, M ;
Valentin, L .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (03) :1293-1297
[14]   Development of new X-ray imaging device sensitive to 0.1-100 keV [J].
Miyata, E ;
Miki, M ;
Tawa, N ;
Kamiyama, D ;
Miyaguchi, K .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 525 (1-2) :122-125
[15]   Novel photon-counting detector for 0.1-100 keV X-ray imaging possessing high spatial resolution [J].
Miyata, E ;
Tamura, K .
JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS & EXPRESS LETTERS, 2003, 42 (10A) :L1201-L1204
[16]   High resolution X-ray sensor for non destructive evaluation [J].
Nagarkar, VV ;
Gordon, JS ;
Vasile, S ;
Gothoskar, P ;
Hopkins, F .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (03) :1559-1563
[17]   The noise performance of electron multiplying charge-coupled devices [J].
Robbins, MS ;
Hadwen, BJ .
IEEE TRANSACTIONS ON ELECTRON DEVICES, 2003, 50 (05) :1227-1232
[18]  
ROWE RK, 1993, J NUCL MED, V34, P474
[19]   Photon penetration and scatter in micro-pinhole imaging: a Monte Carlo investigation [J].
van der Have, F ;
Beekman, FJ .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (08) :1369-1386
[20]   First tests of a Medipix-1 pixel detector for X-ray dynamic defectoscopy [J].
Vavrik, D ;
Jakubek, J ;
Visschers, J ;
Pospisil, S ;
Ponchut, C ;
Zemankova, J .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 487 (1-2) :216-223