Construction of the CLEO III drift chamber

被引:1
作者
Csorna, S
Dickson, M
von Dombrowski, S
Glenn, S
Kravchenko, I
Marka, S
Peterson, D
Thies, P
Thorndike, EH
机构
[1] Vanderbilt Univ, Stevenson Ctr 6301, Nashville, TN 37235 USA
[2] Cornell Univ, Nucl Studies Lab, Ithaca, NY 14853 USA
[3] Univ Rochester, Rochester, NY 14627 USA
[4] Univ Kansas, Lawrence, KS 66045 USA
基金
美国国家科学基金会;
关键词
CLEO III drift chamber; stringing procedure;
D O I
10.1016/S0168-9002(98)00803-1
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The CLEO III group is constructing a new drift chamber to be installed as part of the staged luminosity upgrade program at the Cornell Electron Storage Ring and compatible with the interaction region optics. Although having less radial extent than the current CLEO II tracking system, CLEO III will have equivalent momentum resolution because of material reduction in the drift chamber inner skin and gas. The thin inner skin requires special attention to the endplate motion due to wire creep. During stringing, use of a robot will fully automate the wire handling on the upper end. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:306 / 309
页数:4
相关论文
共 13 条
[1]   DESIGN AND TESTS FOR CLEO-II SILICON VERTEX DETECTOR [J].
ALEXANDER, JP ;
DOBBINS, JA ;
HONSCHEID, K ;
JONES, CD ;
SELEN, M ;
WORDEN, HM ;
WUERTHWEIN, FK ;
GRONBERG, J ;
MORRISON, RJ ;
NELSON, HN ;
SCHMIDT, DM ;
TAJIMA, H ;
CINABRO, D ;
HENDERSON, S ;
YAMAMOTO, H ;
ARTUSO, M ;
RUBIN, P ;
SOBOLEWSKI, Z ;
AKERIB, D ;
COWEN, D .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 326 (1-2) :243-250
[2]   Test beam results from the CLEO III LiF-TEA RICH [J].
Artuso, M ;
Azfar, F ;
Efimov, A ;
Kopp, S ;
Mountain, R ;
Schuh, S ;
Skwarnicki, T ;
Stone, S ;
Viehhauser, G ;
Anderson, S ;
Smith, A ;
Kubota, Y ;
Lipeles, E ;
Coan, T ;
Staeck, J ;
Fadeyev, V ;
Volobouev, I ;
Ye, J .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 419 (2-3) :577-583
[3]  
ARTUSO M, BEAM TESTS CLEO 3 LI
[4]  
*CESR CLEO UPGR PR, 1993, 931265 CLNS CESR CLE
[5]   CLEO and CESR upgrades: Near- and long-term development [J].
Galik, RS .
NUCLEAR PHYSICS B, 1996, :280-287
[6]   Study of helium-based drift chamber gases [J].
Gan, KK ;
Daubenmier, CM ;
Kagan, H ;
Kass, R ;
Sadoff, AJ .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 374 (01) :27-33
[7]   Optimization of silicon microstrip detector design for CLEO III [J].
Hopman, PI ;
Alexander, JP ;
Foland, AD ;
Kim, PC ;
Ward, CW .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 383 (01) :98-103
[8]  
*K BERK CORN LAB N, 1996, 961398 CLNS CESR CLE
[9]   THE CLEO-II DETECTOR [J].
KUBOTA, Y ;
NELSON, JK ;
PERTICONE, D ;
POLING, R ;
SCHRENK, S ;
ALAM, MS ;
BIAN, ZH ;
CHEN, D ;
KIM, IJ ;
LI, WC ;
LOU, XC ;
NEMATI, B ;
SUN, CR ;
WANG, PN ;
ZOELLER, MM ;
CRAWFORD, G ;
FULTON, R ;
GAN, KK ;
JENSEN, T ;
KAGAN, H ;
KASS, R ;
MALCHOW, R ;
MORROW, F ;
SUNG, MK ;
WHITMORE, J ;
WILSON, P ;
BUTLER, F ;
FU, X ;
KALBFLEISCH, G ;
LAMBRECHT, M ;
SKUBIC, P ;
SNOW, J ;
WANG, PL ;
BORTOLETTO, D ;
BROWN, DN ;
CHEN, WY ;
DOMINICK, J ;
MCILWAIN, RL ;
MILLER, DH ;
MODESITT, M ;
SHIBATA, EI ;
SCHAFFNER, SF ;
SHIPSEY, IPJ ;
YAO, WM ;
BATTLE, M ;
KROHA, H ;
SPARKS, K ;
THORNDIKE, EH ;
WANG, CH ;
STROYNOWSKI, R .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 320 (1-2) :66-113