Speciation analysis of antimony by high-performance liquid chromatography inductively coupled plasma mass spectrometry using ultrasonic nebulization

被引:62
作者
Krachler, M [1 ]
Emons, H [1 ]
机构
[1] Res Ctr Juelich, Inst Appl Phys Chem, D-52425 Julich, Germany
关键词
antimony; speciation; high-performance liquid chromatography; inductively coupled plasma mass spectrometry; ultrasonic nebulization;
D O I
10.1016/S0003-2670(00)01252-6
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The two inorganic Sb species Sb(III) and Sb(V) as well as trimethlyantimony dichloride (TMSbCl2) were separated by anion exchange chromatography. HPLC eluents were directly aspirated into the plasma of an ICP-MS using ultrasonic nebulization (USN) with membrane desolvation. Leaching of Sb from glass bottles, especially pronounced under alkaline conditions, distinctly increased background Sb-121 signals. The use of conventional HPLC syringes made of glass resulted in non reproducible blank signals for Sb(V). To overcome these problems, polyethylene bottles for the storage of mobile phases and plastic syringes for the injection of Sb compounds onto the analytical columns were employed. The analysis of Sb(III) standard solutions in the sub mu gl(-1) range prepared by dilution of stock standard solutions with high-purity water revealed that Sb(III) is easily oxidized to Sb(V) within a few hours. Deoxygenating the water for dilution of standards by flashing working standard solution with helium or using 1.25 mM EDTA - which served as mobile phase for the chromatographic separation - for the dilution of standards, no oxidation of Sb(III) was observed, at least for 8 h. USN parameters, such as the temperature of the heating area and of the desolvation area as well as the sweep gas flow rate were systematically optimized. Decreasing the USN heating temperature from the conventional settings of 140-80 degreesC enhanced signal intensities by similar to 25% and caused no condensation of the aspirated mobile phase. After optimization detection limits for all three Sb species in the low ng l(-1) range could be established, namely 14 ngl(-1) for Sb(III), 12 ngl(-1) for Sb(V) and 9 ngl(-1) for TMSbCl2. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:125 / 133
页数:9
相关论文
共 21 条
[1]   DETERMINATION OF ANTIMONY(III), ANTIMONY(V), AND METHYLANTIMONY SPECIES IN NATURAL-WATERS BY ATOMIC-ABSORPTION SPECTROMETRY WITH HYDRIDE GENERATION [J].
ANDREAE, MO ;
ASMODE, JF ;
FOSTER, P ;
VANTDACK, L .
ANALYTICAL CHEMISTRY, 1981, 53 (12) :1766-1771
[2]  
*DFG, 1994, AN HAZ SUBST BIOL MA, V4
[3]  
*DFG, 1996, MAK BAT WERT LIST 19
[4]  
DOAK GO, 1967, INORG SYNTH, V9, P92
[5]   Antimony speciation in freshwater plant extracts by using hydride generation gas chromatography mass spectrometry [J].
Dodd, M ;
Pergantis, SA ;
Cullen, WR ;
Li, H ;
Eigendorf, GK ;
Reimer, KJ .
ANALYST, 1996, 121 (02) :223-228
[6]   Speciation of antimony(III) and antimony(V) using hydride generation inductively coupled plasma atomic emission spectrometry combined with the rate of pre-reduction of antimony [J].
Feng, YL ;
Narasaki, H ;
Chen, HY ;
Tian, LC .
ANALYTICA CHIMICA ACTA, 1999, 386 (03) :297-304
[7]  
Fowler B. A., 1991, METALS THEIR COMPOUN
[8]   Optimized procedure for the determination of antimony in lipid-rich environmental matrices by flow injection hydride generation atomic absorption spectrometry [J].
Krachler, M ;
Burow, M ;
Emons, H .
ANALYST, 1999, 124 (06) :923-926
[9]   Development and evaluation of an analytical procedure for the determination of antimony in plant materials by hydride generation atomic absorption spectrometry [J].
Krachler, M ;
Burow, M ;
Emons, H .
ANALYST, 1999, 124 (05) :777-782
[10]   Biomonitoring of antimony in environmental matrices from terrestrial and limnic ecosystems [J].
Krachler, M ;
Burow, M ;
Emons, H .
JOURNAL OF ENVIRONMENTAL MONITORING, 1999, 1 (05) :477-481