Setup reproducibility in radiation therapy for lung cancer: A comparison between T-bar and expanded foam immobilization devices

被引:35
作者
Halperin, R
Roa, W
Field, M
Hanson, J
Murray, B
机构
[1] Univ Alberta, Dept Oncol, Fac Med & Oral Hlth Sci, Edmonton, AB T6G 1Z2, Canada
[2] Cross Canc Inst, Dept Epidemiol, Edmonton, AB T6G 1Z2, Canada
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1999年 / 43卷 / 01期
关键词
T-bar; expanded foam immobilization device; thoracic radiotherapy; setup reproducibility;
D O I
10.1016/S0360-3016(98)00354-X
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Physiologic and non-physiologic tumor motion complicates the use of tight margins in three-dimensional (3D) conformal radiotherapy. Setup reproducibility is an important non-physiologic cause of tumor motion. The objective of this study is to evaluate and compare patient setup reproducibility using the reusable T-bar and the disposable expanded foam immobilization device (EFID) in radiation therapy for lung cancer. Methods and Materials: Two hundred forty-four portal films were taken from 16 prospectively accrued patients treated for lung cancer. Patients were treated with either a pair of anterior and posterior parallel opposing fields (POF), or a combination of POF and a three-field isocentric technique, Each patient was treated in a supine position using either the T-bar setup or EFID. Six patients were treated in both devices over their treatment courses. Field placement analysis was used to evaluate 3D setup reproducibility, by comparing positions of bony landmarks relative to the radiation field edges in digitized simulator and portal images. Anterior-posterior, lateral, and longitudinal displacements, as well as field rotations along coronal and sagittal planes were measured. Statistical analyses of variance were applied to the deviations among portal films of all patients and the subgroup treated with both immobilization methods. Results: For the T-bar immobilization device, standard deviations of the setup reproducibility were 5.1, 3.7, and 5.1 mm in the anterior-posterior, lateral, and longitudinal dimensions, respectively. Rotations in the coronal plane and the sagittal plane were 0.9 degrees and 1.0 degrees, respectively. For the EFID, corresponding standard deviations of set up reproducibility were 3.6 mm, 5.3 mm, 5.4 mm, 0.7 degrees and 1.4 degrees, respectively, There was no statistically significant difference (p = 0.22) in the 3D setup reproducibility between T-bar and EFID, Subgroup analysis for the patients who were treated with both immobilization devices did not reveal a difference either. There was no consistent systematic error from simulator to treatment unit identified for either immobilization device. Conclusion: Although the optimal immobilization technique and patient positioning for thoracic radiotherapy have yet to be determined, this study indicates that T-bar is comparable with EFID in its setup reproducibility. In view of the inherent advantages of T-bar, it has become a standard immobilization device at our institution. The observed range of displacements in field positioning with either immobilization device implies that one cm (two standard deviations [SD] of setup error) will be a more appropriate margin to allow for setup variability in radiation therapy for lung cancer. (C) 1998 Elsevier Science Inc.
引用
收藏
页码:211 / 216
页数:6
相关论文
共 12 条
[1]   3-DIMENSIONAL CONFORMAL RADIATION-THERAPY MAY IMPROVE THE THERAPEUTIC RATIO OF HIGH-DOSE RADIATION-THERAPY FOR LUNG-CANCER [J].
ARMSTRONG, JG ;
BURMAN, C ;
LEIBEL, S ;
FONTENLA, D ;
KUTCHER, G ;
ZELEFSKY, M ;
FUKS, Z .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 26 (04) :685-689
[2]   3-DIMENSIONAL VERIFICATION OF PATIENT PLACEMENT DURING RADIOTHERAPY USING PORTAL IMAGES [J].
BIJHOLD, J .
MEDICAL PHYSICS, 1993, 20 (02) :347-356
[3]   FAST EVALUATION OF PATIENT SET-UP DURING RADIOTHERAPY BY ALIGNING FEATURES IN PORTAL AND SIMULATOR IMAGES [J].
BIJHOLD, J ;
VANHERK, M ;
VIJLBRIEF, R ;
LEBESQUE, JV .
PHYSICS IN MEDICINE AND BIOLOGY, 1991, 36 (12) :1665-1679
[4]   A RANDOMIZED PHASE-I/II TRIAL OF HYPERFRACTIONATED RADIATION-THERAPY WITH TOTAL DOSES OF 60.0 GY TO 79.2 GY - POSSIBLE SURVIVAL BENEFIT WITH GREATER-THAN-OR-EQUAL-TO 69.6 GY IN FAVORABLE PATIENTS WITH RADIATION-THERAPY ONCOLOGY GROUP STAGE-III NON-SMALL-CELL LUNG-CARCINOMA - REPORT OF RADIATION-THERAPY ONCOLOGY GROUP 83-11 [J].
COX, JD ;
AZARNIA, N ;
BYHARDT, RW ;
SHIN, KH ;
EMAMI, B ;
PAJAK, TF .
JOURNAL OF CLINICAL ONCOLOGY, 1990, 8 (09) :1543-1555
[5]   A quality control study of the accuracy of patient positioning in irradiation of pelvic fields [J].
Creutzberg, CL ;
Althof, VGM ;
deHoog, M ;
Visser, AG ;
Huizenga, H ;
Wijnmaalen, A ;
Levendag, PC .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 34 (03) :697-708
[6]   A RANDOMIZED TRIAL OF INDUCTION CHEMOTHERAPY PLUS HIGH-DOSE RADIATION VERSUS RADIATION ALONE IN STAGE-III NON-SMALL-CELL LUNG-CANCER [J].
DILLMAN, RO ;
SEAGREN, SL ;
PROPERT, KJ ;
GUERRA, J ;
EATON, WL ;
PERRY, MC ;
CAREY, RW ;
FREI, EF ;
GREEN, MR .
NEW ENGLAND JOURNAL OF MEDICINE, 1990, 323 (14) :940-945
[7]  
EMAMI B, 1992, PRINCIPLES PRACTICE, P818
[8]   Accuracy of field alignment in abdominal radiation therapy [J].
Kortmann, RD ;
Hess, CF ;
Meisner, C ;
Schmidberger, H ;
Bamberg, M .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 35 (04) :779-783
[9]   ACCURACY OF RADIATION-FIELD ALIGNMENT IN CLINICAL-PRACTICE [J].
RABINOWITZ, I ;
BROOMBERG, J ;
GOITEIN, M ;
MCCARTHY, K ;
LEONG, J .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1985, 11 (10) :1857-1867
[10]   IMMOBILIZATION IMPROVES THE REPRODUCIBILITY OF PATIENT POSITIONING DURING 6-FIELD CONFORMAL RADIATION-THERAPY FOR PROSTATE CARCINOMA [J].
ROSENTHAL, SA ;
GOLDSMITH, BJ ;
DOGGETT, EC ;
PICKETT, B ;
YUO, HS ;
SOFFEN, EM ;
STERN, RL ;
RYU, JK ;
ROACH, M .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 27 (04) :921-926