An improved MCNP version of the NORMAN voxel phantom for dosimetry studies

被引:41
作者
Ferrari, P [1 ]
Gualdrini, G [1 ]
机构
[1] ENEA, ION, IRP, I-40136 Bologna, Italy
关键词
D O I
10.1088/0031-9155/50/18/005
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In recent years voxel phantoms have been developed on the basis of tomographic data of real individuals allowing new sets of conversion coefficients to be calculated for effective dose. Progress in radiation studies brought ICRP to revise its recommendations and a new report, already circulated in draft form, is expected to change the actual effective dose evaluation method. In the present paper the voxel phantom NORMAN developed at HPA, formerly NRPB, was employed with MCNP Monte Carlo code. A modified version of the phantom, NORMAN-05, was developed to take into account the new set of tissues and weighting factors proposed in the cited ICRP draft. Air kerma to organ equivalent dose and effective dose conversion coefficients for antero-posterior and postero-anterior parallel photon beam irradiations, from 20 keV to 10 MeV, have been calculated and compared with data obtained in other laboratories using different numerical phantoms. Obtained results are in good agreement with published data with some differences for the effective dose calculated employing the proposed new tissue weighting factors set in companson with previous evaluations based on the ICRP 60 report.
引用
收藏
页码:4299 / 4316
页数:18
相关论文
共 41 条
[1]  
[Anonymous], 1991, ANN ICRP, V60
[2]  
[Anonymous], 2000, MCNP GEN MONTE CARLO, DOI DOI 10.1016/J.CCLET.2011.04.015
[3]  
[Anonymous], [No title captured]
[4]  
[Anonymous], 2003, Ann ICRP, V32, P3
[5]  
[Anonymous], 1996, ICRP PUBL
[6]   A new graphical user interface for fast construction of computation phantoms and MCNP calculations: Application to calibration of in vivo measurement systems [J].
Borisov, N ;
Franck, D ;
de Carlan, L ;
Laval, L .
HEALTH PHYSICS, 2002, 83 (02) :272-279
[7]   Fluence-to-dose conversion coefficients from monoenergetic neutrons below 20 MeV based on the VIP-Man anatomical model [J].
Bozkurt, A ;
Chao, TC ;
Xu, XG .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (10) :3059-3079
[8]   Fluence-to-dose conversion coefficients based on the VIP-MAN anatomical model and mcnpx code for monoenergetic neutrons above 20 MeV [J].
Bozkurt, A ;
Chao, TC ;
Xu, XG .
HEALTH PHYSICS, 2001, 81 (02) :184-202
[9]  
BURN KW, 2002, RT200250FIS MCNPX EN
[10]   Conversion coefficients based on the VIP-MAN anatomical model and EGS4-VLSI code for external monoenergetic photons from 10 keV to 10 MeV [J].
Chao, TC ;
Bozkurt, A ;
Xu, XG .
HEALTH PHYSICS, 2001, 81 (02) :163-183