One-molar gadolinium chelate (gadobutrol) as a contrast agent for CT angiography of the thoracic and abdominal aorta

被引:15
作者
Esteban, Jose M. [1 ]
Alonso, Antonio [1 ]
Cervera, Vicente [1 ]
Martinez, Vicente [1 ]
机构
[1] Univ Valencia, Consorcio Hosp Gen, Dept Radiol, ERESA, Valencia, Spain
关键词
gadobutrol; CTA; contrast media; aorta;
D O I
10.1007/s00330-007-0590-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
The aim of our study was to evaluate the use of a 1-molar gadolinium chelate (gadobutrol) as an alternative contrast medium for computed tomography angiography (CTA) exams of the aorta. CTA exams of the thoracic and/or abdominal aorta were performed on 15 patients with contraindications for the use of iodine who were not suitable for magnetic resonance examinations. The exams were performed with a 16-detector row scanner, injecting a mean dose of 0.37 mmol Gd/kg of body weight at a flow rate of 4 ml/s. Creatinine levels were obtained prior to the exam in patients with impaired renal function, and 24 and 48 h afterwards. The mean attenuation values obtained in the middle ascending and middle descending thoracic aorta were 202.3 and 216.8, respectively. The mean HU values of the abdominal aorta were 210.4 at the level of the renal arteries and 186.8 in the aortic bifurcation. All the exams were considered diagnostically adequate. No significant increase in serum creatinine was observed 24 and 48 h after the exam. We believe that gadobutrol could be an alternative contrast medium for CTA exams with 16-detector row scanners in patients with contraindications for iodinated contrast medium.
引用
收藏
页码:2394 / 2400
页数:7
相关论文
共 40 条
[1]
Gadolinium-DTPA as X-ray contrast medium in clinical studies [J].
Albrecht, T ;
Dawson, P .
BRITISH JOURNAL OF RADIOLOGY, 2000, 73 (872) :878-882
[2]
Gadolinium-enhanced computed tomography angiography in multi-detector row computed tomography: Initial observations [J].
Bae, KT ;
McDermott, R ;
Gierada, DS ;
Heiken, JP ;
Nolte, MA ;
Takahashi, N ;
Hong, C .
ACADEMIC RADIOLOGY, 2004, 11 (01) :61-68
[3]
GD-DTPA AS A CONTRAST AGENT IN CT [J].
BLOEM, JL ;
WONDERGEM, J .
RADIOLOGY, 1989, 171 (02) :578-579
[4]
Gadolinium-enhanced MDCT angiography of the abdomen: Feasibility and limitations [J].
Chicoskie, C ;
Tello, R .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 184 (06) :1821-1828
[5]
Demonstration of pulmonary embolism with dynamic gadolinium-enhanced spiral CT [J].
Coche, EE ;
Hammer, FD ;
Goffette, PP .
EUROPEAN RADIOLOGY, 2001, 11 (11) :2306-2309
[6]
Gadolinium contrast media are more nephrotoxic than a low osmolar iodine medium employing doses with equal x-ray attenuation in renal arteriography:: An experimental study in pigs [J].
Elmståhl, B ;
Nyman, U ;
Leander, P ;
Chai, CM ;
Frennby, B ;
Almén, T .
ACADEMIC RADIOLOGY, 2004, 11 (11) :1219-1228
[7]
Acute renal failure after arteriography with a gadolinium-based contrast agent [J].
Gemery, J ;
Idelson, B ;
Reid, S ;
Yucel, EK ;
Pagan-Marin, H ;
Ali, S ;
Casserly, L .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 171 (05) :1277-1278
[8]
Gadolinium as a CT contrast agent: Assessment in a porcine model [J].
Gierada, DS ;
Bae, KT .
RADIOLOGY, 1999, 210 (03) :829-834
[9]
Gadopentetate dimeglumine is potentially an alternative contrast agent for three-dimensional computed tomography angiography with multidetector-row helical scanning [J].
Gupta, AK ;
Alberico, RA ;
Litwin, A ;
Kanter, P ;
Grossman, ZD .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2002, 26 (06) :869-874
[10]
Gadolinium dimeglumine: An alternative contrast agent for digital subtraction angiography in patients with renal failure [J].
Hammer, FD ;
Malaise, J ;
Goffette, PP ;
Mathurin, P .
TRANSPLANTATION PROCEEDINGS, 2000, 32 (02) :432-433