Analysis of fentanyl and norfentanyl in human plasma by liquid chromatography-tandem mass spectrometry using electrospray ionization

被引:37
作者
Day, J [1 ]
Slawson, M [1 ]
Lugo, RA [1 ]
Wilkins, D [1 ]
机构
[1] Univ Utah, Ctr Human Toxicol, Salt Lake City, UT 84112 USA
关键词
D O I
10.1093/jat/27.7.513
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This report describes a sensitive and specific high-performance liquid chromatography (HPLC)-electrospray ionization-tandem mass spectrometry (MS-MS) method for the detection of subnanogram concentrations of fentanyl and its metabolite norfentanyl in human plasma. The assay was based on a liquid-liquid extraction of 0.5 mL of human plasma, with a lower limit of quantitation (LLOQ) of 0.05 ng/mL. Sample extracts were analyzed using a ThermoQuest TSQ® MS-MS interfaced with a Hewlett-Packard series 1100 HPLC and a Phenomenex® (30 × 2.00-mm, 5 μ Luna C18(2)) column. The intra-assay precision and accuracy ranged from 2.1 to 12.5% for both analytes at concentrations of 0.1, 0.5, 1.0, and 10 ng/mL. The interassay accuracy and precision ranged from 7.34 to 10.95%.
引用
收藏
页码:513 / 516
页数:4
相关论文
共 13 条
[1]   Quantitative analysis of fentanyl in rat plasma by gas chromatography with nitrogen-phosphorus detection [J].
Choi, HS ;
Shin, HC ;
Khang, G ;
Rhee, JM ;
Lee, HB .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2001, 765 (01) :63-69
[2]   Determination of subnanogram concentrations of fentanyl in plasma by gas chromatography mass spectrometry: Comparison with standard radioimmunoassay [J].
Fryirsa, B ;
Woodhouse, A ;
Huang, JL ;
Dawson, M ;
Mather, LE .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 1997, 688 (01) :79-85
[3]  
GOODMAN AG, 1996, PHARMACOL BASIS THER, P543
[4]   DETERMINATION OF FENTANYL AND ALFENTANIL IN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ULTRAVIOLET DETECTION [J].
KUMAR, K ;
MORGAN, DJ ;
CRANKSHAW, DP .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1987, 419 :464-468
[5]   Development and validation of an HPLC assay for fentanyl and related substances in fentanyl citrate injection, USP [J].
Lambropoulos, J ;
Spanos, GA ;
Lazaridis, NV ;
Ingallinera, TS ;
Rodriguez, VK .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1999, 20 (04) :705-716
[6]   DETERMINATION OF PLASMA FENTANYL BY GC-MASS SPECTROMETRY AND PHARMACOKINETIC ANALYSIS [J].
LIN, SN ;
WANG, TPF ;
CAPRIOLI, RM ;
MO, BPN .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1981, 70 (11) :1276-1279
[7]   MEASUREMENT OF PLASMA FENTANYL CONCENTRATION - COMPARISON OF 3 METHODS [J].
PHIPPS, JA ;
SABOURIN, MA ;
BUCKINGHAM, W ;
STRUNIN, L .
CANADIAN ANAESTHETISTS SOCIETY JOURNAL, 1983, 30 (02) :162-165
[8]   DETECTION OF PICOGRAM CONCENTRATIONS OF FENTANYL IN PLASMA BY GAS-LIQUID-CHROMATOGRAPHY [J].
PHIPPS, JA ;
SABOURIN, MA ;
BUCKINGHAM, W ;
STRUNIN, L .
JOURNAL OF CHROMATOGRAPHY, 1983, 272 (02) :392-395
[9]   OPTIMIZATION OF THE RADIOIMMUNOASSAYS FOR MEASURING FENTANYL AND ALFENTANIL IN HUMAN-SERUM [J].
SCHUTTLER, J ;
WHITE, PF .
ANESTHESIOLOGY, 1984, 61 (03) :315-320
[10]   A highly automated 96-well solid phase extraction and liquid chromatography/tandem mass spectrometry method for the determination of fentanyl in human plasma [J].
Shou, WZ ;
Jiang, XY ;
Beato, BD ;
Weng, ND .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (07) :466-476