Validation of MTF measurement for digital mammography quality control

被引:74
作者
Carton, AK
Vandenbroucke, D
Struye, L
Maidment, ADA
Kao, YH
Albert, M
Bosmans, H
Marchal, G
机构
[1] Univ Leuven Hosp, B-3000 Louvain, Belgium
[2] Agfa Gevaert, B-2640 Mortsel, Belgium
[3] Hosp Univ Penn, Dept Radiol, Philadelphia, PA 19104 USA
关键词
MTF; digital detectors; simulations;
D O I
10.1118/1.1921667
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
The modulation transfer function (MTF) describes the spatial resolution properties of imaging systems. In this work, the accuracy of our implementation of the edge method for calculating the presampled MTF was examined. Synthetic edge images with known MTF were used as gold standards for determining the robustness of the edge method. These images simulated realistic data from clinical digital mammography systems, and contained intrinsic system factors that could affect the MTF accuracy, such as noise, scatter, and flat-field nonuniformities. Our algorithm is not influenced by detector dose variations for MTF accuracy up to 1/2 the sampling frequency. We investigated several methods for noise reduction, including truncating the supersampled line spread function (LSF), windowing the LSF, applying a local exponential fit to the LSF, and applying a monotonic constraint to the supersampled edge spread function. Only the monotonic constraint did not introduce a systematic error; the other methods could result in MTF underestimation. Overall, our edge method consistently computed MTFs which were in good agreement with the true WE The edge method was then applied to images from a commercial storage-phosphor based digital mammography system. The calculated MTF was affected by the size (sides of 2.5, 5, or 10 cm) and the composition (lead or tungsten) of the edge device. However, the effects on the MTF were observed only with regard to the low frequency drop (LFD). Scatter nonuniformity was dependent on edge size, and could lead to slight underestimation of LFD. Nevertheless, this negative effect could be minimized by using an edge of 5 cm or larger. An edge composed of lead is susceptible to L-fluorescence, which causes overestimation of the LFD. The results of this work are intended to underline the need for clear guidelines if the MTF is to be given a more crucial role in acceptance tests and routine assessment of digital mammography systems: the MTF algorithm and edge object test tool need to be publicly validated. (c) 2005 American Association of Physicists in Medicine.
引用
收藏
页码:1684 / 1695
页数:12
相关论文
共 22 条
[1]
[Anonymous], 1986, 41 ICRU
[2]
Estimation of the noisy component of anatomical backgrounds [J].
Bochud, FO ;
Valley, JF ;
Verdun, FR ;
Hessler, C ;
Schnyder, P .
MEDICAL PHYSICS, 1999, 26 (07) :1365-1370
[3]
Accuracy of a simple method for deriving the presampled modulation transfer function of a digital radiographic system from an edge image [J].
Buhr, E ;
Günther-Kohfahl, S ;
Neitzel, U .
MEDICAL PHYSICS, 2003, 30 (09) :2323-2331
[4]
CARTON AK, THESIS
[5]
SIGNAL AND NOISE IN MODULATION TRANSFER-FUNCTION DETERMINATIONS USING THE SLIT, WIRE, AND EDGE TECHNIQUES [J].
CUNNINGHAM, IA ;
REID, BK .
MEDICAL PHYSICS, 1992, 19 (04) :1037-1044
[6]
Dobbins JT, 2000, HDB MED IMAGING PHYS, V1
[7]
*EUR PROT QUAL CON, 2003, ADD DIG MAMM
[8]
Performance evaluation of a "dual-side read" dedicated mammography computed radiography system [J].
Fetterly, KA ;
Schueler, BA .
MEDICAL PHYSICS, 2003, 30 (07) :1843-1854
[9]
A SIMPLE METHOD FOR DETERMINING THE MODULATION TRANSFER-FUNCTION IN DIGITAL RADIOGRAPHY [J].
FUJITA, H ;
TSAI, DY ;
ITOH, T ;
DOI, K ;
MORISHITA, J ;
UEDA, K ;
OHTSUKA, A .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1992, 11 (01) :34-39
[10]
Evaluation of an algorithm for the assessment of the MTF using an edge method [J].
Greer, PB ;
van Doorn, T .
MEDICAL PHYSICS, 2000, 27 (09) :2048-2059