High throughput label-free platform for statistical bio-molecular sensing

被引:36
作者
Bosco, Filippo G. [1 ]
Hwu, En-Te [2 ]
Chen, Ching-Hsiu [2 ]
Keller, Stephan [1 ]
Bache, Michael [1 ]
Jakobsen, Mogens H. [1 ]
Hwang, Ing-Shouh [2 ]
Boisen, Anja [2 ]
机构
[1] Tech Univ Denmark, Dept Micro & Nanotechnol, DK-2800 Lyngby, Denmark
[2] Acad Sinica, Inst Phys, Nankang 11529, Taiwan
关键词
CELL DETECTION; MICROCANTILEVERS; SENSORS; 2,6-DICHLOROBENZAMIDE; IMMUNOASSAY; BINDING;
D O I
10.1039/c1lc20116f
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Sensors are crucial in many daily operations including security, environmental control, human diagnostics and patient monitoring. Screening and online monitoring require reliable and high-throughput sensing. We report on the demonstration of a high-throughput label-free sensor platform utilizing cantilever based sensors. These sensors have often been acclaimed to facilitate highly parallelized operation. Unfortunately, so far no concept has been presented which offers large datasets as well as easy liquid sample handling. We use optics and mechanics from a DVD player to handle liquid samples and to read-out cantilever deflection and resonant frequency. Also, surface roughness is measured. When combined with cantilever deflection the roughness is discovered to hold valuable additional information on specific and unspecific binding events. In a few minutes, 30 liquid samples can be analyzed in parallel, each by 24 cantilever-based sensors. The approach was used to detect the binding of streptavidin and antibodies.
引用
收藏
页码:2411 / 2416
页数:6
相关论文
共 34 条
[1]   ATOMIC FORCE MICROSCOPE [J].
BINNIG, G ;
QUATE, CF ;
GERBER, C .
PHYSICAL REVIEW LETTERS, 1986, 56 (09) :930-933
[2]   Environmental sensors based on micromachined cantilevers with integrated read-out [J].
Boisen, A ;
Thaysen, J ;
Jensenius, H ;
Hansen, O .
ULTRAMICROSCOPY, 2000, 82 (1-4) :11-16
[3]   Self-aligned cantilever positioning for on-substrate measurements using DVD pickup head [J].
Bosco, F. G. ;
Hwu, E. -T. ;
Keller, S. ;
Greve, A. ;
Boisen, A. .
MICROELECTRONIC ENGINEERING, 2010, 87 (5-8) :708-711
[4]  
Braun T, 2009, NAT NANOTECHNOL, V4, P179, DOI [10.1038/nnano.2008.398, 10.1038/NNANO.2008.398]
[5]   A quantitative enzyme-linked immunoassay for the detection of 2,6-dichlorobenzamide (BAM), a degradation product of the herbicide dichlobenil [J].
Bruun, L ;
Koch, C ;
Pedersen, B ;
Jakobsen, MH ;
Aamand, J .
JOURNAL OF IMMUNOLOGICAL METHODS, 2000, 240 (1-2) :133-142
[6]   CALCULATION OF THERMAL NOISE IN ATOMIC-FORCE MICROSCOPY [J].
BUTT, HJ ;
JASCHKE, M .
NANOTECHNOLOGY, 1995, 6 (01) :1-7
[7]   Sorption of the herbicide dichlobenil and the metabolite 2,6-dichlorobenzamide on soils and aquifer sediments [J].
Clausen, L ;
Larsen, F ;
Albrechtsen, HJ .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2004, 38 (17) :4510-4518
[8]   Cantilever Sensors: Nanomechanical Tools for Diagnostics [J].
Datar, Ram ;
Kim, Seonghwan ;
Jeon, Sangmin ;
Hesketh, Peter ;
Manalis, Scott ;
Boisen, Anja ;
Thundat, Thomas .
MRS BULLETIN, 2009, 34 (06) :449-454
[9]   Microfabricated centrifugal microfluidic systems: Characterization and multiple enzymatic assays [J].
Duffy, DC ;
Gillis, HL ;
Lin, J ;
Sheppard, NF ;
Kellogg, GJ .
ANALYTICAL CHEMISTRY, 1999, 71 (20) :4669-4678
[10]   Cantilever biosensors [J].
Fritz, Juergen .
ANALYST, 2008, 133 (07) :855-863