摘要
An enzymatic lysine electrode is developed for the potentiometric analysis of lysine (Lys). This lysine biosensor consists of a chemically immobilized lysine oxidase membrane attached to an all-solid-state ammonium electrode. In this system, the enzymatic degradation of lysine produces ammonia, which is then detected with the ammonium electrode. The influence of immobilization conditions on the potentiometric response and the lifetime of the electrode was studied. Under optimal conditions, the relationship between the potentiometric response and the log [Lys] was linear between 3x10(-5) and 10(-3) M, the sensitivity was 50 mV/decade, the repeatability 1.4%, and the response time t(95%) was 15 s. (C) 1998 Elsevier Science B.V, All rights reserved.
引用
收藏
页码:49 / 56
页数:8
相关论文
共 12 条
[1]   Selective biosensing of L-lysine by a low-temperature flow-injection technique using an immobilized lysine oxidase reactor [J].
Chen, RLC ;
Lee, MH ;
Matsumoto, K .
ANALYTICAL SCIENCES, 1996, 12 (01) :87-90
[2]   DETERMINATION OF 1-LYSINE IN FEEDS BY FLUOROMETRIC METHOD BASED ON 1-LYSINE OXIDASE [J].
HIKUMA, M ;
KAWARAI, M ;
TONOOKA, Y ;
HASHIMOTO, K .
ANALYTICAL LETTERS, 1991, 24 (12) :2225-2236
[3]  
HORNBY WE, 1975, IMMOBILIZED ENZYMES, P141
[4]   AMPEROMETRIC LYSINE BIOPROBES ANALYSIS IN FEEDS [J].
LAVAGNINI, MG ;
MOSCONE, D ;
PALLESCHI, G ;
COMPAGNONE, D ;
CREMISINI, C .
TALANTA, 1993, 40 (08) :1301-1306
[5]   AN OPTICAL BIOSENSOR FOR LYSINE BASED ON THE USE OF LYSINE DECARBOXYLASE AND A CADAVERINE-SENSITIVE MEMBRANE [J].
LI, H ;
HE, HR ;
WOLFBEIS, OS .
BIOSENSORS & BIOELECTRONICS, 1992, 7 (10) :725-732
[6]  
Marconi E, 1996, ANAL LETT, V29, P1125, DOI 10.1080/00032719608001463
[7]   ENZYMATIC DETERMINATION OF L-LYSINE BY FLOW-INJECTION TECHNIQUES [J].
POHLMANN, A ;
STAMM, WW ;
KUSAKABE, H ;
KULA, MR .
ANALYTICA CHIMICA ACTA, 1990, 235 (02) :329-335
[8]   CHEMILUMINOMETRIC L-LYSINE DETERMINATION WITH IMMOBILIZED LYSINE OXIDASE BY FLOW-INJECTION ANALYSIS [J].
PREUSCHOFF, F ;
SPOHN, U ;
WEBER, E ;
UNVERHAU, K ;
MOHR, KH .
ANALYTICA CHIMICA ACTA, 1993, 280 (02) :185-189
[9]   PHOTODIODE-BASED CHEMILUMINOMETRIC BIOSENSORS FOR HYDROGEN-PEROXIDE AND L-LYSINE [J].
PREUSCHOFF, F ;
SPOHN, U ;
JANASEK, D ;
WEBER, E .
BIOSENSORS & BIOELECTRONICS, 1994, 9 (08) :543-549
[10]   A LYSINE SENSOR FOR PROCESS-CONTROL [J].
SIEGLER, K ;
WEBER, B ;
WEBER, E ;
TONDER, K ;
KLINGNER, E ;
RIECHERT, F .
JOURNAL OF CHEMICAL TECHNOLOGY AND BIOTECHNOLOGY, 1994, 59 (03) :279-287