Effect of high-temperature on high-performance liquid chromatography column stability and performance under temperature-programmed conditions

被引:72
作者
Marin, SJ [1 ]
Jones, BA [1 ]
Felix, WD [1 ]
Clark, J [1 ]
机构
[1] Seler Technol Inc, Salt Lake City, UT 84104 USA
关键词
temperature effects; temperature programming; column performance; column stability; stability studies;
D O I
10.1016/j.chroma.2003.10.092
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Six commercially available analytical (4.1 or 4.6 mm i.d.) columns were evaluated under temperature-programmed high-temperature liquid chromatography (HTLC) conditions to access their stability and performance at extreme temperatures. Seven components consisting of acidic, basic and neutral compounds were analyzed under temperature-programmed conditions and solvent gradient conditions using three different mobile phase compositions (acidic, basic and neutral). Each column was checked with a two-component test mix at various stages of the evaluation to look for signs of stationary phase collapse. Three zirconia based stationary phases studied exhibited column bleed under temperature-programmed conditions. The other three columns, a polydentate silica column, a polystyrene-divinylbenzene (PS-DVB) polymeric column, and a graphitic carbon column performed well with no evidence of stationary phase degradation. The R.S.D. for the retention times and efficiencies were less than 10% for most conditions, and not more than 15% during the course of the evaluation for each column. The polydentate silica stationary phase was temperature programmed to 100degreesC, the PS-DVB stationary phase was temperature programmed up to 150degreesC, and the graphitic carbon column was used with temperature programming up to 200degreesC. Comparable peak capacities and similar retention behaviors were observed under solvent gradient and temperature-programmed conditions. Temperature programming with dynamic mobile phase preheating can replace solvent gradient analysis without a loss of peak capacity when used with 4.1 or 4.6 nun columns. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:255 / 262
页数:8
相关论文
共 24 条
[11]  
Greibrokk T, 2001, J SEP SCI, V24, P899, DOI 10.1002/1615-9314(20011201)24:12<899::AID-JSSC899>3.3.CO
[12]  
2-B
[13]   High-temperature liquid chromatography [J].
Greibrokk, T ;
Andersen, T .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1000 (1-2) :743-755
[14]  
Ingelse BA, 1998, HRC-J HIGH RES CHROM, V21, P613
[15]  
JONES B, 2003, P PITTSB C ORL FL 9, P2020
[16]   Separation of selected basic pharmaceuticals by reversed-phase and ion-exchange chromatography using thermally tuned tandem columns [J].
Mao, Y ;
Carr, PW .
ANALYTICAL CHEMISTRY, 2001, 73 (18) :4478-4485
[17]   Subcritical water chromatography with flame ionization detection [J].
Miller, DJ ;
Hawthorne, SB .
ANALYTICAL CHEMISTRY, 1997, 69 (04) :623-627
[18]   SEPARATION OF PROTEINS BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY .2. OPTIMIZING SAMPLE PRETREATMENT AND MOBILE PHASE CONDITIONS [J].
NUGENT, KD ;
BURTON, WG ;
SLATTERY, TK ;
JOHNSON, BF ;
SNYDER, LR .
JOURNAL OF CHROMATOGRAPHY, 1988, 443 :381-397
[19]   INFLUENCE OF THERMAL CONDITIONS ON THE EFFICIENCY OF HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC COLUMNS [J].
POPPE, H ;
KRAAK, JC .
JOURNAL OF CHROMATOGRAPHY, 1983, 282 (DEC) :399-412
[20]   Superheated heavy water as the eluent for HPLC-NMR and HPLC-NMR-MS of model drugs [J].
Smith, RM ;
Chienthavorn, O ;
Wilson, ID ;
Wright, B ;
Taylor, SD .
ANALYTICAL CHEMISTRY, 1999, 71 (20) :4493-4497