The evaluation of post-operative alignment in total knee replacement using a CT-based navigation system

被引:102
作者
Mizu-uchi, H. [1 ]
Matsuda, S. [1 ]
Miura, H. [1 ]
Okazaki, K. [1 ]
Akasaki, Y. [1 ]
Iwamoto, Y. [1 ]
机构
[1] Kyushu Univ, Grad Sch Med Sci, Dept Orthopaed Surg, Higashi Ku, Fukuoka 8128582, Japan
来源
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME | 2008年 / 90B卷 / 08期
关键词
D O I
10.1302/0301-620X.90B8.20265
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We compared the alignment of 39 total knee replacements implanted using the conventional alignment guide system with 37 implanted using a CT-based navigation system, performed by a single surgeon. The knees were evaluated using full-length weight-bearing anteroposterior radiographs, lateral radiographs and CT scans. The mean hip-knee-ankle angle, coronal femoral component angle and coronal tibial component angle were 181.8 degrees (174.2 degrees to 188.3 degrees), 88.5 degrees (84.0 degrees to 91.8 degrees) and 89.7 degrees (86.3 degrees to 95.1 degrees), respectively for the conventional group and 180.8 degrees (178.2 degrees to 185.1 degrees), 89.3 degrees (85.8 degrees to 92.0 degrees) and 89.9 degrees (88.0 degrees to 93.0 degrees), respectively for the navigated group. The mean sagittal femoral component angle was 85.5 (80.6 to 92.8) for the conventional group and 89.6 degrees (85.5 degrees to 94.0 degrees) for the navigated group. The mean rotational femoral and tibial component angles were -0.7 degrees (-8.8 degrees to 9.8 degrees) and -3.3 degrees (-16.8 degrees to 5.8 degrees) for the conventional group and -0.6 degrees (-3.5 degrees to 3.0 degrees) and 0.3 degrees (-5.3 degrees to 7.7 degrees) for the navigated group. The ideal angles of all alignments in the navigated group were obtained at significantly higher rates than in the conventional group. Our results demonstrated significant improvements in component positioning with a CT-based navigation system, especially with respect to rotational alignment.
引用
收藏
页码:1025 / 1031
页数:7
相关论文
共 40 条
[1]
Radiological results of image-based and non-image-based computer-assisted total knee arthroplasty [J].
Bäthis, H ;
Perlick, L ;
Tingart, M ;
Lüring, C ;
Perlick, C ;
Grifka, J .
INTERNATIONAL ORTHOPAEDICS, 2004, 28 (02) :87-90
[2]
BERGER RA, 1993, CLIN ORTHOP RELAT R, V286, P40
[3]
BERGER RA, 1998, CLIN ORTHOP RELAT R, V356, P144
[4]
Computer-assisted knee arthroplasty versus a conventional jig-based technique -: A randomised, prospective trial [J].
Chauhan, SK ;
Scott, RG ;
Breidahl, W ;
Beaver, RJ .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2004, 86B (03) :372-377
[5]
Hands-on robotic unicompartmental knee replacement - A prospective, randomised controlled study of the Acrobot system [J].
Cobb, J ;
Henckel, J ;
Gomes, P ;
Harris, S ;
Jakopec, M ;
Rodriguez y Baena, F ;
Barrett, A ;
Davies, B .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2006, 88B (02) :188-197
[6]
Dynamic Intraoperative ligament balancing for total knee arthroplasty [J].
D'Lima, Darryl D. ;
Patil, Shantanu ;
Steklov, Nikolai ;
Colwell, Clifford W., Jr. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2007, (463) :208-212
[7]
Hydroxyapatite-coated total knee replacement - Clinical experience at 10 to 15 years [J].
Epinette, J. -A. ;
Manley, M. T. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2007, 89B (01) :34-38
[8]
Sterilization and wear-related failure in first- and second-generation press-fit condylar total knee arthroplasty [J].
Griffin, William L. ;
Fehring, Thomas K. ;
Pomeroy, Donald L. ;
Gruen, Thomas A. ;
Murphy, Jeffrey A. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2007, (464) :16-20
[9]
INSALL JN, 1989, CLIN ORTHOP RELAT R, P13
[10]
CORONAL ALIGNMENT AFTER TOTAL KNEE REPLACEMENT [J].
JEFFERY, RS ;
MORRIS, RW ;
DENHAM, RA .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1991, 73 (05) :709-714