Development of an up-converting phosphor technology-based 10-channel lateral flow assay for profiling antibodies against Yersinia pestis

被引:73
作者
Hong, Wenyan [1 ]
Huang, Lihua [2 ]
Wang, Haoran [1 ]
Qu, Jianfeng [2 ]
Guo, Zhaobiao [1 ]
Xie, Chengke [2 ]
Zhu, Ziwen [1 ]
Zhang, Youbao [2 ]
Du, Zongmin [1 ]
Yan, Yanfeng [1 ]
Zheng, Yan [3 ]
Huang, Huijie [2 ]
Yang, Ruifu [1 ]
Zhou, Lei [1 ]
机构
[1] Beijing Inst Microbiol & Epidemiol, Lab Analyt Microbiol, State Key Lab Pathogen & Biosecur, Beijing 100071, Peoples R China
[2] Chinese Acad Sci, Shanghai Inst Opt & Fine Mech, Shanghai 201800, Peoples R China
[3] Shanghai Kerune Phosphor Technol Co Ltd, Shanghai 201108, Peoples R China
基金
北京市自然科学基金;
关键词
Up-converting phosphor; Lateral flow assay; Multi-detection; Antibodies profiling; Yersinia pestis; QUANTITATIVE DETECTION; RAPID-DETECTION; IMMUNOASSAY; ANTIGEN; IMMUNOSENSORS; MICROARRAYS; RESPONSES; VACCINE; SERUM;
D O I
10.1016/j.mimet.2010.08.005
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this study, a 10-channel up-converting phosphor technology-based lateral flow (TC-UPT-LF) assay was developed to profile antibodies against Yersinia pestis. Ten expressed Y. pestis proteins were covalently conjugated with an up-converting phosphor particle to develop double-antigen sandwich immunochromatographic strips to detect corresponding antibodies. After optimization one by one, each strip was integrated into a TC-UPT-LF disc for simultaneously detection of different antibodies. A scanning biosensor was also developed to acquire the results. The performance of the TC-UPT-LF assay was evaluated by using standard samples and plague monkey serum samples. Fifty-one patient serum samples were detected by the TC-UPT-LF assay. The TC-UPT-LF disc could be stable for 10 days at 37 degrees C with an average CV of 10.3%. Its sensitivity and qualitative results are comparable to those of ELISA. Its linearity fitting coefficient of determination (R-2) for different antibody detection is between 0.93 and 0.99. Besides F1 antibody, the LcrV and YopD antibodies also showed higher positive ratio than the other seven antibodies, as 100% (13/13) and 92% (12/13) in monkey sera and 86.3% (44/51) and 66.7% (34/51) in patient sera, respectively. It is suggested that the TC-UPT-LF assay has been successfully developed for multi-detection and LcrV and YopD can be the potential diagnostic markers of the plague. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:133 / 140
页数:8
相关论文
共 25 条
[1]  
Bacarese-Hamilton Tito, 2004, Methods Mol Biol, V264, P271
[2]   Up-converting phosphor technology-based lateral flow assay for detection of Schistosoma circulating anodic antigen in serum [J].
Corstjens, Paul L. A. M. ;
van Lieshout, Lisette ;
Zuiderwijk, Michel ;
Kornelis, Dieuwke ;
Tanke, Hans J. ;
Deelder, Andre M. ;
van Dam, Govert J. .
JOURNAL OF CLINICAL MICROBIOLOGY, 2008, 46 (01) :171-176
[3]   Rapid assay format for multiplex detection of humoral immune responses to infectious disease pathogens (HIV, HCV, and TB) [J].
Corstjens, Paul L. A. M. ;
Chen, Zongyuang ;
Zuiderwijk, Michel ;
Bau, Haim H. ;
Abrams, William R. ;
Malamud, Daniel ;
Niedbala, R. Sam ;
Tanke, Hans J. .
ORAL-BASED DIAGNOSTICS, 2007, 1098 :437-445
[4]   Bacillus anthracis:: toxicology, epidemiology and current rapid-detection methods [J].
Edwards, KA ;
Clancy, HA ;
Baeumner, AJ .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2006, 384 (01) :73-84
[5]  
Ehricht Ralf, 2009, V509, P85, DOI 10.1007/978-1-59745-372-1_6
[6]   Characterization of Multienzyme-Antibody-Carbon Nanotube Bioconjugates for Immunosensors [J].
Jensen, Gary C. ;
Yu, Xin ;
Gong, Joseph D. ;
Munge, Bernard ;
Bhirde, Ashwin ;
Kim, Sang N. ;
Papadimitrakopoulos, Fotios ;
Rusling, James F. .
JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2009, 9 (01) :249-255
[7]   Nano-bio-chips for high performance multiplexed protein detection: Determinations of cancer biomarkers in serum and saliva using quantum dot bioconjugate labels [J].
Jokerst, Jesse V. ;
Raamanathan, Archana ;
Christodoulides, Nicolaos ;
Floriano, Pierre N. ;
Pollard, Amanda A. ;
Simmons, Glennon W. ;
Wong, Jorge ;
Gage, Carole ;
Furmaga, Wieslaw B. ;
Redding, Spencer W. ;
McDevitt, John T. .
BIOSENSORS & BIOELECTRONICS, 2009, 24 (12) :3622-3629
[8]   Protein Microarray for profiling antibody responses to Yersinia pestis live vaccine [J].
Li, B ;
Jiang, LX ;
Song, QF ;
Yang, JX ;
Chen, ZL ;
Guo, ZB ;
Zhou, DS ;
Du, ZM ;
Song, YJ ;
Wang, J ;
Wang, HX ;
Yu, SY ;
Wang, J ;
Yang, RF .
INFECTION AND IMMUNITY, 2005, 73 (06) :3734-3739
[9]   Development of up-converting phosphor technology-based lateral-flow assay for rapidly quantitative detection of hepatitis B surface antibody [J].
Li, Luping ;
Zhou, Lei ;
Yu, Yang ;
Zhu, Ziwen ;
Lin, Changqing ;
Lu, Changlong ;
Yang, Ruifu .
DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2009, 63 (02) :165-172
[10]   Nanomaterial labels in electrochemical immunosensors and immunoassays [J].
Liu, Guodong ;
Lin, Yuehe .
TALANTA, 2007, 74 (03) :308-317