Reliability of left ventricular volumes and function measurements using three-dimensional speckle tracking echocardiography

被引:95
作者
Kleijn, Sebastiaan A. [1 ,2 ,3 ]
Aly, Mohamed F. A. [1 ,2 ]
Terwee, Caroline B. [4 ,5 ]
van Rossum, Albert C. [1 ,2 ,3 ]
Kamp, Otto [1 ,2 ,3 ]
机构
[1] Vrije Univ Amsterdam Med Ctr, Dept Cardiol, Amsterdam, Netherlands
[2] Vrije Univ Amsterdam Med Ctr, Inst Cardiovasc Res ICaR VU, Amsterdam, Netherlands
[3] ICIN, Utrecht, Netherlands
[4] Vrije Univ Amsterdam Med Ctr, Dept Epidemiol & Biostat, Amsterdam, Netherlands
[5] Vrije Univ Amsterdam Med Ctr, EMGO Inst Hlth & Care Res, Amsterdam, Netherlands
关键词
Reliability; Three-dimensional imaging; Speckle tracking; Echocardiography; Left ventricle; CARDIAC MAGNETIC-RESONANCE; QUANTITATIVE ASSESSMENT; QUANTIFICATION; REPRODUCIBILITY; ACCURACY; STRAIN;
D O I
10.1093/ejechocard/jer174
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims Although the accuracy of three-dimensional speckle tracking echocardiography (STE) to quantify left ventricular (LV) volumes and function has been demonstrated, its reliability has not been studied in great detail. The aim of the study was to determine inter-observer, intra-observer, and test-retest reliability of echocardiographic measurements of LV volumes and function using three-dimensional STE. Methods and results A total of 140 consecutive patients presenting for routine echocardiographic examination underwent three-dimensional STE. Twenty-three of the 140 patients (16%) were excluded from the analysis due to atrial fibrillation or insufficient image quality. In the remaining 117 patients [69 males, age 59 +/- 16 years, ejection fraction (EF) 51+13%], intra-observer and inter-observer reliability of LV volumes, EF, and global and segmental strain measurements was determined, whereas test-retest reliability was assessed in a subgroup of 50 patients. LV volumes and EF measurements demonstrated good reliability [intraclass correlation coefficient (ICC): 0.85-0.99; standard error of measurement (SEM): 3.1-9.2 mL and 1.7-4.0%, respectively]. Reliability of global circumferential strain measurements (ICC: 0.85-0.97; SEM: 1.4-2.6%) was superior to longitudinal (ICC: 0.66-0.92; SEM: 1.0-2.1%) and radial strain measurements (ICC: 0.52-0.88; SEM: 4.4-8.1%), with similar results found for segmental strain measurements (P<0.001 for all). Reliability was not significantly affected by the image quality or temporal resolution of 3D data sets for any parameter. Conclusion Good intra-observer, inter-observer, and test-retest reliability support the use of three-dimensional STE for routine evaluation of LV volumes and EF. Global and segmental circumferential strain measurements also demonstrate high reliability, whereas analysis by a single observer is currently recommended for longitudinal and radial strain due to limited inter-observer and test-retest reliability.
引用
收藏
页码:159 / 168
页数:10
相关论文
共 22 条
[1]   Analysis of myocardial deformation based on pixel tracking in two dimensional echocardiographic images enables quantitative assessment of regional left ventricular function [J].
Becker, M. ;
Bilke, E. ;
Kuehl, H. ;
Katoh, M. ;
Kramann, R. ;
Franke, A. ;
Buecker, A. ;
Hanrath, P. ;
Hoffmann, R. .
HEART, 2006, 92 (08) :1102-1108
[2]   Reliability of Visual Assessment of Global and Segmental Left Ventricular Function: A Multicenter Study by the Israeli Echocardiography Research Group [J].
Blondheim, David S. ;
Beeri, Ronen ;
Feinberg, Micha S. ;
Vaturi, Mordehay ;
Shimoni, Sarah ;
Fehske, Wolfgang ;
Sagie, Alik ;
Rosenmann, David ;
Lysyansky, Peter ;
Deutsch, Lisa ;
Leitman, Marina ;
Kuperstein, Rafael ;
Hay, Ilan ;
Gilon, Dan ;
Friedman, Zvi ;
Agmon, Yoram ;
Tsadok, Yossi ;
Liel-Cohen, Noah .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2010, 23 (03) :258-264
[3]  
Castro PL, 2000, BIOMED SCI INSTRUM, V395, P197
[4]   Relative importance of errors in left ventricular quantitation by two-dimensional echocardiography: Insights from three-dimensional echocardiography and cardiac magnetic resonance imaging [J].
Chukwu, Ebere O. ;
Barasch, Eddy ;
Mihalatos, Dennis G. ;
Katz, Alan ;
Lachmann, Justine ;
Han, Jing ;
Reichek, Nathaniel ;
Gopal, Aasha S. .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2008, 21 (09) :990-997
[5]   When to use agreement versus reliability measures [J].
de Vet, Henrica C. W. ;
Terwee, Caroline B. ;
Knol, Dirk L. ;
Bouter, Lex M. .
JOURNAL OF CLINICAL EPIDEMIOLOGY, 2006, 59 (10) :1033-1039
[6]  
Fleiss J., 1986, Reliability of measurement: the design and analysis of clinical experiments
[7]   Assessment of Myocardial Mechanics Using Speckle Tracking Echocardiography: Fundamentals and Clinical Applications [J].
Geyer, Holly ;
Caracciolo, Giuseppe ;
Abe, Haruhiko ;
Wilansky, Susan ;
Carerj, Scipione ;
Gentile, Federico ;
Nesser, Hans-Joachim ;
Khandheria, Bijoy ;
Narula, Jagat ;
Sengupta, Partho P. .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2010, 23 (04) :351-369
[8]   Analysis of regional left ventricular function by cineventriculography, cardiac magnetic resonance imaging, and unenhanced and contrast-enhanced echocardiography - A multicenter comparison of methods [J].
Hoffmann, R ;
von Bardeleben, S ;
Kasprzak, JD ;
Borges, AC ;
ten Cate, F ;
Firschke, C ;
Lafitte, S ;
Al-Saadi, N ;
Kuntz-Hehner, S ;
Horstick, G ;
Greis, C ;
Engelhardt, M ;
Vanoverschelde, JL ;
Becher, H .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (01) :121-128
[9]   Rapid online quantification of left ventricular volume from real-time three-dimensional echocardiographic data [J].
Jacobs, LD ;
Salgo, IS ;
Goonewardena, S ;
Weinert, L ;
Coon, P ;
Bardo, D ;
Gerard, O ;
Allain, P ;
Zamorano, JL ;
de Isla, LP ;
Mor-Avi, V ;
Lang, RM .
EUROPEAN HEART JOURNAL, 2006, 27 (04) :460-468
[10]   Reproducibility and accuracy of echocardiographic measurements of left ventricular parameters using real-time three-dimensional echocardiography [J].
Jenkins, C ;
Bricknell, K ;
Hanekom, L ;
Marwick, TH .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 44 (04) :878-886