Direct analysis of pharmaceutical drug formulations using ion mobility spectrometry/quadrupole-time-of-flight mass spectrometry combined with desorption electrospray ionization

被引:186
作者
Weston, DJ
Bateman, R
Wilson, ID
Wood, TR
Creaser, CS [1 ]
机构
[1] Nottingham Trent Univ, Sch Biomed & Nat Sci, Interdisciplinary Biomed Res Ctr, Nottingham NG11 8NS, England
[2] Waters Corp, Manchester M23 9LZ, Lancs, England
[3] AstraZeneca, Macclesfield SK10 4TF, Cheshire, England
[4] GlaxoSmithKline Inc, Stevenage SG1 2NY, Herts, England
关键词
D O I
10.1021/ac051277q
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel approach to the rapid analysis of pharmaceutical drug formulations using hyphenated ion mobility spectrometry (IMS) and time-of-flight mass spectrometry (ToF-MS) that requires no sample pretreatment or chromatographic separation is described. A modified quadrupole time-of-flight mass spectrometer containing an ion mobility drift cell was used for gas-phase electrophoretic separation of ions prior to ToF-MS detection. The generation of sample ions directly from tablets and cream formulations was effected by desorption electrospray ionization (DESI) using a modified electrospray ion source. The analysis of a range of over-the-counter and prescription tablet fonnulations is described, including histamine H-2 receptor antagonist (ranitidine), analgesic (paracetamol), opiate (codeine), and aromatase inhibitor anticancer (anastrozole) drugs. The successful determination of active drugs from soft formulations, such as an antiseptic cream (chlorhexidine) and a nicotine-containing skin patch, is also presented. Limits of detection for the active drugs using the DESI/IMS/ToF-MS method fell within the high-picomole to nanomole range. In all cases, the use of ion mobility drift tube separation showed increased selectivity for active drug responses (present as low as 0.14% w/w) over excipient responses such as poly(ethylene glycol). Tandem mass spectrometric analysis of precursor ions separated by IMS allowed positive confirmation of active drugs with little loss of ion mobility efficiency. The ability to analyze hard or soft pharmaceutical formulations directly by DESI combined with ion mobility spectrometry/mass spectrometry in similar to 2 min demonstrates the potential applicability of this novel method to pharmaceutical screening of low-molecular-weight drug formulations with high selectivity over the formulation vehicle.
引用
收藏
页码:7572 / 7580
页数:9
相关论文
共 30 条
[21]   Ion mobility-mass spectrometry: a new paradigm for proteomics [J].
McLean, JA ;
Ruotolo, BT ;
Gillig, KJ ;
Russell, DH .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2005, 240 (03) :301-315
[22]   Ion mobility-mass spectrometry applied to cyclic peptide analysis: Conformational preferences of gramicidin S and linear analogs in the gas phase [J].
Ruotolo, BT ;
Tate, CC ;
Russell, DH .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2004, 15 (06) :870-878
[23]   Analysis of protein mixtures by matrix-assisted laser desorption ionization-ion mobility-orthogonal-time-of-flight mass spectrometry [J].
Ruotolo, BT ;
Gillig, KJ ;
Stone, EG ;
Russell, DH ;
Fuhrer, K ;
Gonin, M ;
Schultz, JA .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2002, 219 (01) :253-267
[24]   Detection of perfluorocarbons using ion mobility spectrometry [J].
Schmidt, H ;
Baumbach, JI ;
Klockow, D .
ANALYTICA CHIMICA ACTA, 2003, 484 (01) :63-74
[25]  
Takáts Z, 2005, CHEM COMMUN, P1950, DOI 10.1039/b418697d
[26]   Mass spectrometry sampling under ambient conditions with desorption electrospray ionization [J].
Takáts, Z ;
Wiseman, JM ;
Gologan, B ;
Cooks, RG .
SCIENCE, 2004, 306 (5695) :471-473
[27]  
TURNER RB, 1994, TRAC-TREND ANAL CHEM, V13, P275, DOI 10.1016/0165-9936(94)87064-0
[28]   Thin-layer chromatography and mass spectrometry coupled using desorption electrospray ionization [J].
Van Berkel, GJ ;
Ford, MJ ;
Deibel, MA .
ANALYTICAL CHEMISTRY, 2005, 77 (05) :1207-1215
[29]   INCLUSION OF A MALDI ION-SOURCE IN THE ION CHROMATOGRAPHY TECHNIQUE - CONFORMATIONAL INFORMATION ON POLYMER AND BIOMOLECULAR IONS [J].
VON HELDEN, G ;
WYTTENBACH, T ;
BOWERS, MT .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 1995, 146 :349-364
[30]   Construction and characterization of a high-flow, high-resolution ion mobility spectrometer for detection of explosives after personnel portal sampling [J].
Wu, C ;
Steiner, WE ;
Tornatore, PS ;
Matz, LM ;
Siems, WF ;
Atkinson, DA ;
Hill, HH .
TALANTA, 2002, 57 (01) :123-134