Renal embolization: Feasibility of magnetic resonance-guidance using active catheter tracking and intraarterial magnetic resonance angiography

被引:34
作者
Fink, C
Bock, M
Umathum, R
Volz, S
Zuehlsdorff, S
Grobholz, R
Kauczor, HU
Hallscheidt, P
机构
[1] Deutsch Krebsforschungszentrum, Dept Radiol E010, D-69120 Heidelberg, Germany
[2] Heidelberg Univ, Dept Med Phys Radiol E020, D-6900 Heidelberg, Germany
[3] Univ Hosp Mannheim, Dept Pathol, Mannheim, Germany
[4] Univ Heidelberg Hosp, Dept Radiol, Heidelberg, Germany
关键词
magnetic resonance imaging; renal cancer; embolization; interventional radiology;
D O I
10.1097/01.rli.0000110744.70512.df
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
Rationale and Objectives: Magnetic resonance (MR)-guidance of endovascular interventions offers various advantages, including the absence of ionizing radiation, excellent soft tissue contrast, and multiplanar and functional imaging capabilities. The objective of this study was to assess the feasibility of MR-guided renal embolization using active catheter tracking with automatic slice positioning and intraarterial contrast-enhanced MR angiography (MRA). Materials and Methods: MR-guided embolization of 16 kidneys was attempted in 15 pigs using real-time tracking of active 5-Fr. catheters, Embolization was monitored by selective intraarterial projection MRA. Intraarterial three-dimensional (3D) MRA was used for the assessment of embolization results. Additional pathologic correlation was available in 2 animals. The image quality of intraarterial 3D contrast-enhanced-MRA was rated by an independent radiologist who was not involved in the animal experiments. Results: Active catheter tracking with automatic slice positioning allowed reliable catheter guidance and catheterization of the renal artery in all animals. Embolization was successful in all kidneys (11 left, 5 right), as verified by intraarterial 3D contrast-enhanced MRA (ce-MRA) and/or pathology. The image quality of intraarterial 3D ce-MRA was rated excellent in 10 animals, moderate in 4 animals, and poor in 1 animal. Conclusion: Renal embolization using active catheter tracking and intraarterial ce-MRA is feasible. Selective intraarterial ce-MRA allows the assessment of blood supply and organ perfusion before, during, and after therapeutic interventions, thereby complementing MR-guided endovascular interventions.
引用
收藏
页码:111 / 119
页数:9
相关论文
共 45 条
[1]
Araki Takuji, 2002, Radiat Med, V20, P1
[2]
Bakal C W, 1993, J Vasc Interv Radiol, V4, P727, DOI 10.1016/S1051-0443(93)71958-2
[3]
Visualization of dedicated catheters using fast scanning techniques with potential for MR-guided vascular interventions [J].
Bakker, CJ ;
Hoogeveen, RM ;
Weber, J ;
vanVaals, JJ ;
Viergever, MA ;
Mali, WP .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (06) :816-820
[4]
Bartels LW, 2000, J MAGN RESON IMAGING, V12, P599, DOI 10.1002/1522-2586(200010)12:4<599::AID-JMRI13>3.3.CO
[5]
2-Z
[6]
BOCK M, IN PRESS J MAGN RESO
[7]
Bos C, 2000, MAGN RESON MED, V44, P575, DOI 10.1002/1522-2594(200010)44:4<575::AID-MRM11>3.0.CO
[8]
2-S
[9]
MR-guided coil embolisation of renal arteries in an animal model [J].
Bücker, A ;
Neuerburg, JM ;
Adam, G ;
Glowinski, A ;
van Vaals, JJ ;
Günther, RW .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2003, 175 (02) :271-274
[10]
Simultaneous real-time visualization of the catheter tip and vascular anatomy for MR-guided PTA of iliac arteries in an animal model [J].
Buecker, A ;
Adam, GB ;
Neuerburg, JM ;
Kinzel, S ;
Glowinski, A ;
Schaeffter, T ;
Rasche, V ;
van Vaals, JJ ;
Guenther, RW .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2002, 16 (02) :201-208