Clinical application of a flat-panel x-ray detector based on amorphous silicon technology:: Image quality and potential for radiation dose reduction in skeletal radiography

被引:58
作者
Strotzer, M
Gmeinwieser, J
Völk, M
Fründ, R
Seitz, J
Manke, C
Albrich, H
Feuerbach, S
机构
[1] Univ Hosp Regensburg, Dept Diagnost Radiol, D-93042 Regensburg, Germany
[2] Klinikum Furth, D-90766 Furth, Germany
关键词
D O I
10.2214/ajr.171.1.9648757
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study was to compare images obtained with a self-scanning, flat-panel X-ray detector based on amorphous silicon technology with conventional screen-film radiographs and to evaluate the possibility of radiation dose reduction in skeletal radiography. SUBJECTS AND METHODS. One hundred twenty patients were examined prospectively using a conventional screen-film system (speed, 400; detector dose, 2.5 mu Gy) and a prototype digital amorphous silicon detector (simulated speed, 400 and 800, n = 120; simulated speed, 1600, n = 40). The resulting 400 images were evaluated independently by six radiologists using a subjective five-point preference scale that rated overexposure, underexposure, contrast resolution, spatial resolution, and soft-tissue presentation. Image quality was ranked on a scale from 0 to 10 according to subjective criteria. Statistical significance of differences was determined using Student's t test and confidence intervals (95% confidence level). RESULTS. Comparison of conventional radiographs with digital images revealed a statistically significant preference for the digital system for soft-tissue presentation (speed 400 and 800) and visualization of osteoarthrotic changes (speed 400). A small but statistically significant preference for conventional images was found with respect to contrast and spatial resolution when digital speed was 800 or 1600; and the visibility of arthrosis at digital speed 1600, osteolysis at digital speed 800 and 1600, and fractures at digital speed 1600. CONCLUSION. The amorphous silicon-based system with a simulated speed of 400 provided images equivalent to screen-film radiographs. For clinical tasks such as routine follow-up studies, assessment of instability, or orthopedic measurements, a radiation dose reduction of up to 75% may be possible.
引用
收藏
页码:23 / 27
页数:5
相关论文
共 8 条
[1]   DEMONSTRATION OF MEGAVOLTAGE AND DIAGNOSTIC-X-RAY IMAGING WITH HYDROGENATED AMORPHOUS-SILICON ARRAYS [J].
ANTONUK, LE ;
BOUDRY, J ;
HUANG, WD ;
MCSHAN, DL ;
MORTON, EJ ;
YORKSTON, J ;
LONGO, MJ ;
STREET, RA .
MEDICAL PHYSICS, 1992, 19 (06) :1455-1466
[2]   A REAL-TIME, FLAT-PANEL, AMORPHOUS-SILICON, DIGITAL X-RAY IMAGER [J].
ANTONUK, LE ;
YORKSTON, J ;
HUANG, WD ;
SIEWERDSEN, JH ;
BOUDRY, JM ;
ELMOHRI, Y ;
MARX, MV .
RADIOGRAPHICS, 1995, 15 (04) :993-1000
[3]   SELENIUM-BASED DIGITAL RADIOGRAPHY OF THE CHEST - RADIOLOGISTS PREFERENCE COMPARED WITH FILM-SCREEN RADIOGRAPHS [J].
FLOYD, CE ;
BAKER, JA ;
CHOTAS, HG ;
DELONG, DM ;
RAVIN, CE .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 165 (06) :1353-1358
[4]   The AAPM/RSNA physics tutorial for residents - Measures of screen-film performance [J].
Haus, AG .
RADIOGRAPHICS, 1996, 16 (05) :1165-1181
[5]   MONTE-CARLO CALCULATIONS OF X-RAY SCATTER DATA FOR DIAGNOSTIC-RADIOLOGY [J].
KALENDER, W .
PHYSICS IN MEDICINE AND BIOLOGY, 1981, 26 (05) :835-849
[6]   MEASUREMENT OF OBSERVER AGREEMENT FOR CATEGORICAL DATA [J].
LANDIS, JR ;
KOCH, GG .
BIOMETRICS, 1977, 33 (01) :159-174
[7]   A NEW ASYMMETRIC SCREEN-FILM COMBINATION FOR CONVENTIONAL CHEST RADIOGRAPHY - EVALUATION IN 50 PATIENTS [J].
SWENSEN, SJ ;
GRAY, JE ;
BROWN, LR ;
AUGHENBAUGH, GL ;
HARMS, GF ;
STEARS, J .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (03) :483-486
[8]   Flat-panel X-ray detector using amorphous silicon technology - Reduced radiation dose for the detection of foreign bodies [J].
Volk, M ;
Strotzer, M ;
Gmeinwieser, J ;
Alexander, J ;
Frund, R ;
Seitz, J ;
Manke, C ;
Spahn, M ;
Feuerbach, S .
INVESTIGATIVE RADIOLOGY, 1997, 32 (07) :373-377