Precise scale of spectral responsivity for InGaAs detectors based on a cryogenic radiometer and several laser sources

被引:20
作者
Werner, L [1 ]
Friedrich, R [1 ]
Johannsen, U [1 ]
Steiger, A [1 ]
机构
[1] Phys Tech Bundesanstalt, D-10587 Berlin, Germany
关键词
D O I
10.1088/0026-1394/37/5/39
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The Physikalisch-Technische Bundesanstalt (PTB) has developed a spectral responsivity scale in the spectral range 0.95 mum to 1.6 mum The responsivity scale was established by calibrating InGaAs photodiodes against the PTB radiation thermometry cryogenic radiometer (RTCR) using several laser sources: a Ti:sapphire laser (0.850 mum to 1.02 mum); a Nd:YAG laser (1.064 mum); and two diode lasers (1.31 mum, 1.55 mum) At intermediate wavelengths the responsivity was interpolated with the help of thermal cavity detectors of high emissivity. In this way the high accuracy of the scale at the laser wavelengths can be maintained over almost the entire spectral region. A detailed discussion is given of the uncertainties achieved in the calibration with the RTCR and the interpolation with the thermal detector.
引用
收藏
页码:523 / 526
页数:4
相关论文
共 10 条
[1]  
[Anonymous], P TEMPMEKO 1999 7 IN
[2]   PHOTODIODE NONLINEARITY MEASUREMENT WITH AN INTENSITY STABILIZED LASER AS A RADIATION SOURCE [J].
FISCHER, J ;
FU, L .
APPLIED OPTICS, 1993, 32 (22) :4187-4190
[3]   Establishing a new ultraviolet and near-infrared spectral responsivity scale [J].
Fox, NP ;
Theocharous, E ;
Ward, TH .
METROLOGIA, 1998, 35 (04) :535-541
[4]  
Friedrich R., 1995, METROLOGIA, V32, P509
[5]  
FU L, 1993, METROLOGIA, V30, P297
[6]   Wall-stabilized arc-plasma source for radiometric applications in the range 200 nm to 10 μm [J].
Grützmacher, K .
METROLOGIA, 2000, 37 (05) :465-468
[7]   Realization of an infrared spectral radiant power response scale on a cryogenic bolometer [J].
Migdall, A ;
Eppeldauer, G .
METROLOGIA, 1998, 35 (04) :307-315
[8]   UTILIZATION OF ABSOLUTE RADIOMETERS IN USSR NATIONAL STANDARDS OF IRRADIANCE UNITS [J].
MOROZOVA, SP ;
SAPRITSKY, VI ;
PAVLOVICH, MN .
METROLOGIA, 1991, 28 (03) :117-120
[9]   A comparison of the performance of infrared detectors for radiometric applications. [J].
Theocharous, E ;
Fox, NP ;
Prior, TR .
OPTICAL RADIATION MEASUREMENTS III, 1996, 2815 :56-68
[10]   Accurate determination of the spectral responsivity of silicon trap detectors between 238 nm and 1015 nm using a laser-based cryogenic radiometer [J].
Werner, L ;
Fischer, J ;
Johannsen, U ;
Hartmann, J .
METROLOGIA, 2000, 37 (04) :279-284