Demonstration of correlations between clinical and physical image quality measures in chest and lumbar spine screen-film radiography

被引:39
作者
Sandborg, M [1 ]
Tingberg, A
Dance, DR
Lanhede, B
Almén, A
McVey, G
Sund, P
Kheddache, S
Besjakov, J
Mattsson, S
Månsson, LG
Carlsson, GA
机构
[1] Linkoping Univ, Fac Hlth Sci, Dept Radiat Phys, SE-58185 Linkoping, Sweden
[2] Univ Lund, Malmo Univ Hosp, Dept Radiat Phys, SE-20502 Malmo, Sweden
[3] Univ Lund, Malmo Univ Hosp, Dept Diagnost Radiol, SE-20502 Malmo, Sweden
[4] Royal Marsden NHS Trust, Joint Dept Phys, London SW3 6JJ, England
[5] Sahlgrens Univ Hosp, Univ Gothenburg, Dept Radiat Phys, SE-41345 Gothenburg, Sweden
[6] Sahlgrens Univ Hosp, Univ Gothenburg, Dept Radiol, SE-41345 Gothenburg, Sweden
关键词
D O I
10.1259/bjr.74.882.740520
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The ability to predict clinical image quality from physical measures is useful for optimization in diagnostic radiology. In this work, clinical and physical assessments of image quality are compared and correlations between the two are derived. Clinical assessment has been made by a group of expert radiologists who evaluated fulfilment of the European image criteria for chest and lumbar spine radiography using two scoring methods: image criteria score (ICS) and visual grading analysis score (VGAS). Physical image quality measures were calculated using a Monte Carlo simulation model of the complete imaging system. This model includes a voxelized male anatomy and was used to calculate contrast and signal-to-noise ratio of various Important anatomical details and measures of dynamic range. Correlations between the physical image quality measures on the one hand and the ICS and VGAS on the other were sought. 16 chest and 4 lumbar spine imaging system configurations were compared in frontal projection. A statistically significant correlation with clinical image quality was found in chest posteroanterior radiography for the contrast of blood vessels in the retrocardiac area and a measure of useful dynamic range. In lumbar spine anteroposterior radiography, a similar significant correlation with clinical image quality was found between the contrast and signal-to-noise ratio of the trabecular structures in the L1-L5 vertebrae. The significant correlation shows that clinical image duality can, at least in some cases, be predicted from appropriate measures of physical image quality.
引用
收藏
页码:520 / 528
页数:9
相关论文
共 19 条
[1]   The influence of different technique factors on image quality of lumbar spine radiographs as evaluated by established CEC image criteria [J].
Almén, A ;
Tingberg, A ;
Mattsson, S ;
Besjakov, J ;
Kheddache, S ;
Lanhede, B ;
Månsson, LG ;
Zankl, M .
BRITISH JOURNAL OF RADIOLOGY, 2000, 73 (875) :1192-1199
[2]   The use of carbon fibre material in radiographic cassettes: Estimation of the dose and contrast advantages [J].
Dance, DR ;
Lester, SA ;
Carlsson, GA ;
Sandborg, M ;
Persliden, J .
BRITISH JOURNAL OF RADIOLOGY, 1997, 70 (832) :383-390
[3]   Calibration and validation of a voxel phantom for use in the Monte Carlo modeling and optimisation of X-ray imaging systems [J].
Dance, DR ;
McVey, G ;
Sadborg, M ;
Persliden, J ;
Carlsson, GA .
MEDICAL IMAGING 1999: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 1999, 3659 :548-559
[4]  
*EU, 1997, OFFICIAL J EUROPEA L, V180, P40
[5]  
*EUR COMM, 1990, 12952 EUR
[6]  
*INT COMM RAD PROT, 1996, ICRP PUBL, V73
[7]  
*INT ORG STAND, 1996, 9236 ISO
[8]  
International Commision on Radiation Units, 1995, 54 ICRU
[9]  
KWANHONG NG, 1998, SUBJECT DOSE RADIOLO
[10]   The influence of different technique factors on image quality for chest radiographs:: Application of the recent CEC image quality criteria [J].
Lanhede, B ;
Tingberg, A ;
Månsson, LG ;
Kheddache, S ;
Widell, M ;
Björneld, L ;
Sund, P .
RADIATION PROTECTION DOSIMETRY, 2000, 90 (1-2) :203-206