Femoral head to neck offset after hip resurfacing is critical for range of motion

被引:12
作者
Girard, J. [1 ,2 ,3 ]
Krantz, N. [1 ,2 ]
Bocquet, D. [1 ,2 ]
Wavreille, G. [1 ,2 ]
Migaud, H. [1 ,2 ]
机构
[1] Univ Lille Nord France, F-59000 Lille, France
[2] Univ Hosp Lille, Dept Orthopaed, Hop Roger Salengro, F-59037 Lille, France
[3] Univ Hosp Lille, Sports Med Dept, F-59037 Lille, France
关键词
Hip resurfacing; Flexion; Range of motion; Head to neck ratio; ACETABULAR BONE; ARTHROPLASTY; COMPONENT; NAVIGATION; ARTHRITIS; SIZE;
D O I
10.1016/j.clinbiomech.2011.08.013
中图分类号
R318 [生物医学工程];
学科分类号
100103 [病原生物学];
摘要
Background: Range of motion after hip arthroplasty may be limited by soft tissues around the hip, extra-articular contact and femoral stem-neck contact with the acetabular articular surface. Femoral head-neck diameter ratio is recognized as a major factor influencing hip range of motion. In hip resurfacing, range of motion is constrained by "cup component to femoral neck" contact. To avoid cup-to-bone contact or to increase the degree of flexion at which it occurs, anterior translation of the femoral component relative to the central femoral neck axis may improve anterior head-neck offset and hip flexion. We questioned whether low or high anterior femoral head to neck offset, cup inclination, stem anteversion, and component size influenced postoperative range of motion and hip flexion in patients who had undergone hip resurfacing. Methods: We prospectively followed 66 patients (68 hips) who underwent hip resurfacing at a mean age at operation of 46.4 years (range, 19-60 years). Mean follow-up was 37.5 months (range, 33-41 months). No patient was lost to follow-up. All patients were evaluated clinically and range of motion was precised. Radiological measurement evaluated the anterior femoral head-neck offset. Findings: Mean anterior neck-head offset was 7.5 mm (range, 5-12 mm). We found significant linear regression correlation between anterior offset and flexion (R = 0.66) and between anterior offset and global range of motion (R = 0.51). One millimeter of anterior offset increased hip range of motion by 5 degrees in flexion. No significant correlations were found between global range of motion or flexion arc of motion and component size, stem anteversion, cup inclination, gender ratio, preoperative arc of flexion or global range of motion. Interpretation: Restoring or improving deficient anterior femoral head-neck offset appears important for restoring postoperative range of motion and specifically hip flexion. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:165 / 169
页数:5
相关论文
共 40 条
[21]
Cup Anteversion in Hip Resurfacing: Validation of EBRA and the Presentation of a Simple Clinical Grading System [J].
Langton, David J. ;
Sprowson, Andrew P. ;
Mahadeva, Dhirendra ;
Bhatnagar, Sharad ;
Holland, James P. ;
Nargol, Antoni V. F. .
JOURNAL OF ARTHROPLASTY, 2010, 25 (04) :607-613
[22]
Factors affecting acetabular bone loss during primary hip arthroplasty -: A quantitative analysis using computer simulation [J].
Lavigne, Martin ;
Rama, Reddi Krishna Boddu Siva ;
Ganapathi, Muthu ;
Nuno, Natalia ;
Winzenrieth, Renaud ;
Vendittoli, Pascal-Andre .
CLINICAL BIOMECHANICS, 2008, 23 (05) :577-583
[23]
Range of motion of large head total hip arthroplasty is greater than 28 mm total hip arthroplasty or hip resurfacing [J].
Lavigne, Martin ;
Ganapathi, Muthu ;
Mottard, Sophie ;
Girard, Julien ;
Vendittoli, Pascal-Andre .
CLINICAL BIOMECHANICS, 2011, 26 (03) :267-273
[24]
Impingement with total hip replacement [J].
Malik, Aamer ;
Maheshwari, Aditya ;
Dorr, Lawrence D. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2007, 89A (08) :1832-1842
[25]
Hip Flexion After Birmingham Hip Resurfacing Role of Cup Anteversion, Anterior Femoral Head-Neck Offset, and Head-Neck Ratio [J].
Malviya, Ajay ;
Lingard, Elizabeth A. ;
Malik, Atul ;
Bowman, Russell ;
Holland, James P. .
JOURNAL OF ARTHROPLASTY, 2010, 25 (03) :387-391
[26]
MARKOLF KL, 1980, CLIN ORTHOP RELAT R, P170
[27]
Massin P, 1989, J Arthroplasty, V4, P245, DOI 10.1016/S0883-5403(89)80020-8
[28]
Correlation of measured range of hip motion following total hip arthroplasty and responses to a questionnaire [J].
McGrory, BJ ;
Freiberg, AA ;
Shinar, AA ;
Harris, WH .
JOURNAL OF ARTHROPLASTY, 1996, 11 (05) :565-571
[29]
Merle D'Aubigne R., 1970, REV CHIR ORTHOP, V56, P481
[30]
Postural balance during quiet standing in patients with total hip arthroplasty and surface replacement arthroplasty [J].
Nantel, Julie ;
Termoz, Nicolas ;
Centomo, Hugo ;
Lavigne, Martin ;
Vendittoli, Pascal-Andre ;
Prince, Francois .
CLINICAL BIOMECHANICS, 2008, 23 (04) :402-407