In situ preparation of a cholesterol biosensor:: entrapment of cholesterol oxidase in an overoxidized polypyrrole film electrodeposited in a flow system -: Determination of total cholesterol in serum

被引:159
作者
Vidal, JC [1 ]
García, E [1 ]
Castillo, JR [1 ]
机构
[1] Univ Zaragoza, Dept Analyt Chem, Analyt Spect & Sensors Grp, Fac Sci, E-50009 Zaragoza, Spain
关键词
polypyrrole electropolymerization; cholesterol biosensor; flow system; cholesterol oxidase entrapment;
D O I
10.1016/S0003-2670(98)00838-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A straightforward method for constructing cholesterol biosensors by entrapment of cholesterol oxidase within a polypyrrole (PPy) film electropolymerized in a flow system is proposed. This method enables adjustment of the biosensor characteristics and features low reagent consumption. Prior to use, the PPy film is overoxidized to provide it with anion-exclusion properties in order to minimize the interference of electroactive species such as ascorbic acid and uric acid. A comprehensive preliminary study of the influence of 2-propanol and Triton X-100 added to the cholesterol solution on the flow-injection determination of this substrate, and the effects of different experimental variables on the biosensor response and its selectivity against interfering electroactive species was carried out, The proposed cholesterol oxidase based biosensor, named Pt/PPy-ChOx, was applied to the determination of cholesterol in reference serum samples, and the results were consistent with certified values. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:213 / 222
页数:10
相关论文
共 21 条
[1]   Improvement of the analytical characteristics of an enzyme electrode for free and total cholesterol via laponite clay additives [J].
Besombes, JL ;
Cosnier, S ;
Labbe, P ;
Reverdy, G .
ANALYTICA CHIMICA ACTA, 1995, 317 (1-3) :275-280
[2]   Improvement of poly(amphiphilic pyrrole) enzyme electrodes via the incorporation of synthetic laponite-clay-nanoparticles [J].
Besombes, JL ;
Cosnier, S ;
Labbe, P .
TALANTA, 1997, 44 (12) :2209-2215
[3]   APPLICATIONS OF REDOX POLYMERS IN BIOSENSORS [J].
BOGUSLAVSKY, L ;
HALE, PD ;
GENG, L ;
SKOTHEIM, TA ;
LEE, HS .
SOLID STATE IONICS, 1993, 60 (1-3) :189-197
[4]   THIN-FILM BIENZYME AMPEROMETRIC BIOSENSORS BASED ON POLYMERIC REDOX MEDIATORS WITH ELECTROSTATIC BIPOLAR PROTECTING LAYER [J].
BOGUSLAVSKY, L ;
KALASH, H ;
XU, Z ;
BECKLES, D ;
GENG, L ;
SKOTHEIM, T ;
LAURINAVICIUS, V ;
LEE, HS .
ANALYTICA CHIMICA ACTA, 1995, 311 (01) :15-21
[5]   Amperometric determination of cholesterol in serum with use of a renewable surface peroxidase electrode [J].
Charpentier, L ;
ElMurr, N .
ANALYTICA CHIMICA ACTA, 1995, 318 (01) :89-93
[6]   Prediction and characterization of the charge/size exclusion properties of over-oxidized poly(pyrrole) films [J].
Farrington, AM ;
Slater, JM .
ELECTROANALYSIS, 1997, 9 (11) :843-847
[7]   FABRICATION AND CHARACTERIZATION OF A SCREEN-PRINTED, DISPOSABLE, AMPEROMETRIC CHOLESTEROL BIOSENSOR [J].
GILMARTIN, MAT ;
HART, JP .
ANALYST, 1994, 119 (11) :2331-2336
[8]   AMPEROMETRIC POLYPYRROLE ENZYME ELECTRODES - EFFECT OF PERMEABILITY AND ENZYME LOCATION [J].
HAMMERLE, M ;
SCHUHMANN, W ;
SCHMIDT, HL .
SENSORS AND ACTUATORS B-CHEMICAL, 1992, 6 (1-3) :106-112
[9]  
HARRISON TR, 1998, HARRISONS PRINCIPLES, V2, pA2
[10]   Flow injection analysis as a tool for studying polymer modified electrodes [J].
Kubiak, WW ;
Wang, J .
ANALYTICA CHIMICA ACTA, 1996, 329 (1-2) :181-189