Cholinesterase sensors based on screen-printed electrodes for detection of organophosphorus and carbamic pesticides

被引:61
作者
Ivanov, A
Evtugyn, G
Budnikov, H
Ricci, F
Moscone, D
Palleschi, G
机构
[1] Kazan VI Lenin State Univ, Dept Chem, Kazan 420008, Russia
[2] Univ Roma Tor Vergata, Dipartimento Sci & Technol Chim, I-00133 Rome, Italy
关键词
cholinesterase sensor; biosensor; pesticide detection; grapes testing;
D O I
10.1007/s00216-003-2174-9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Cholinesterase sensors based on screen-printed electrodes modified with polyaniline, 7,7',8,8'-tetracyanoquinodimethane (TCNQ), and Prussian blue have been developed and tested for detection of anticholinesterase pesticides in aqueous solution and in spiked grape juice. The influence of enzyme source and detection mode on biosensor performance was explored. It was shown that modification of the electrodes results in significant improvement of their analytical characteristics for pesticide determination. Thus, the slopes of the calibration curves obtained with modified electrodes were increased twofold and the detection limits of the pesticides were reduced by factors of 1.6 to 1.8 in comparison with the use of unmodified transducers. The biosensors developed make it possible to detect down to 2x10(-8) mol L-1 chloropyrifos-methyl, 5x10(-8) mol L-1 coumaphos, and 8x10(-9) mol L-1 carbofuran in aqueous solution and grape juice. The optimal conditions for grape juice pretreatment were determined to diminish interference from the sample matrix.
引用
收藏
页码:624 / 631
页数:8
相关论文
共 37 条
  • [1] Thick-film biosensors for pesticides produced by screen-printing of graphite-epoxy composite and biocomposite pastes
    Albareda-Sirvent, M
    Merkoçi, A
    Alegret, S
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2001, 79 (01) : 48 - 57
  • [2] A disposable multielectrode biosensor for rapid simultaneous detection of the insecticides paraoxon and carbofuran at high resolution
    Bachmann, TT
    Schmid, RD
    [J]. ANALYTICA CHIMICA ACTA, 1999, 401 (1-2) : 95 - 103
  • [3] BARRETT DS, 1985, VET HUM TOXICOL, V27, P22
  • [4] Thick-film graphite electrodes in stripping voltammetry
    Brainin, K
    Henze, G
    Stozhko, N
    Malakhova, N
    Faller, C
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 364 (04): : 285 - 295
  • [5] BRESTKIN AP, 1983, USP KHIM+, V52, P1624
  • [6] CLINICAL CONFIRMATION OF ORGANOPHOSHPATE POISONING OF AGRICULTURAL-WORKERS
    COYE, MJ
    BARNETT, PG
    MIDTLING, JE
    VELASCO, AR
    ROMERO, P
    CLEMENTS, CL
    OMALLEY, MA
    TOBIN, MW
    LOWRY, L
    [J]. AMERICAN JOURNAL OF INDUSTRIAL MEDICINE, 1986, 10 (04) : 399 - 409
  • [7] Self-gelatinizable copolymer immobilized glucose biosensor based on Prussian Blue modified graphite electrode
    Deng, Q
    Li, B
    Dong, SJ
    [J]. ANALYST, 1998, 123 (10) : 1995 - 1999
  • [8] Doretti L, 1999, BIOTECHNOL APPL BIOC, V29, P67
  • [9] PESTICIDE-SENSITIVE ISFET BASED ON ENZYME-INHIBITION
    DUMSCHAT, C
    MULLER, H
    STEIN, K
    SCHWEDT, G
    [J]. ANALYTICA CHIMICA ACTA, 1991, 252 (1-2) : 7 - 9
  • [10] DZYADEVICH SV, 1994, ELECTROANAL, V6, P752