Study of laser ablation of brass materials using inductively coupled plasma atomic emission spectrometric detection

被引:32
作者
Gagean, M [1 ]
Mermet, JM [1 ]
机构
[1] Univ Lyon 1, Ecole Super Chim Phys & Elect, Sci Analyt Lab, UMR 5619, F-69622 Villeurbanne, France
关键词
laser ablation; inductively coupled plasma; atomic emission spectrometry; brass materials;
D O I
10.1016/S0584-8547(98)00082-2
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
A XeCl laser and a Q-switched Nd:YAG laser operating at 1064, 532, 355 and 266 nm were used to ablate brass materials with varying concentrations of Zn and Cu. The ablated material was transported to an inductively coupled plasma for further atomization, excitation and ionization with an atomic emission spectrometric detection. A Zn enhancement was observed, which could be suppressed by using a Nd:YAG laser working at 266 nm with fluences higher than 400 J cm(-2) (equivalent to 80 GW cm(-2)). In contrast, a lack of linearity was observed for Cu as a function of the concentration, regardless of the wavelength and the fluence. The Cu problem seemed to occur during the ablation and was related to the structure of the brass material. Lack of linearity was also observed for Zn and other contained elements when samples from different origins were used. (C) 1998 Elsevier Science B.V.
引用
收藏
页码:581 / 591
页数:11
相关论文
共 25 条
[11]   Study of UV laser ablation of nitrided steels using inductively coupled plasma atomic emission spectrometry [J].
Kanicky, V ;
Musil, J ;
Benda, M ;
Mermet, JM .
COLLECTION OF CZECHOSLOVAK CHEMICAL COMMUNICATIONS, 1996, 61 (08) :1167-1176
[12]   Determination of Zr and Ti in 3-mu m-thick ZrTiN ceramic coating using laser ablation inductively coupled plasma atomic emission spectrometry [J].
Kanicky, V ;
Musil, J ;
Mermet, JM .
APPLIED SPECTROSCOPY, 1997, 51 (07) :1037-1041
[13]  
KAWAGUCHI H, 1982, BUNSEKI KAGAKU, V31, pE185
[14]   THE DIRECT DETERMINATION OF TRACE-METALS IN GOLD AND SILVER MATERIALS BY LASER-ABLATION INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY WITHOUT MATRIX MATCHED STANDARDS [J].
KOGAN, VV ;
HINDS, MW ;
RAMENDIK, GI .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1994, 49 (04) :333-343
[15]   Influence of sample surface condition on chemical analysis using laser ablation inductively coupled plasma atomic emission spectroscopy [J].
Mao, XL ;
Chan, WT ;
Russo, RE .
APPLIED SPECTROSCOPY, 1997, 51 (07) :1047-1054
[16]   Preferential vaporization and plasma shielding during nano-second laser ablation [J].
Mao, XL ;
Chan, WT ;
Caetano, M ;
Shannon, MA ;
Russo, RE .
APPLIED SURFACE SCIENCE, 1996, 96-8 :126-130
[17]   Optimization and calibration of laser ablation inductively coupled plasma atomic emission spectrometry by measuring vertical spatial intensity profiles [J].
Mao, XL ;
Russo, RE .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (02) :177-182
[18]   NONDESTRUCTIVE SAMPLING METHOD OF METALS AND ALLOYS FOR LASER ABLATION-INDUCTIVELY COUPLED PLASMA-MASS SPECTROMETRY [J].
RAITH, A ;
HUTTON, RC ;
ABELL, ID ;
CRIGHTON, J .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1995, 10 (09) :591-594
[19]   COMPARISON OF DIFFERENT EXCITATION SOURCES AND NORMALIZATION TECHNIQUES IN LASER-ABLATION AES USING A PHOTODIODE-BASED SPECTROMETER [J].
RICHNER, P ;
BORER, MW ;
BRUSHWYLER, KR ;
HIEFTJE, GM .
APPLIED SPECTROSCOPY, 1990, 44 (08) :1290-1296
[20]   The effect of sodium on analyte ionic line intensities in inductively coupled plasma atomic emission spectrometry: Influence of the operating conditions [J].
Romero, X ;
Poussel, E ;
Mermet, JM .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1997, 52 (04) :495-502