Application of factorial designs and Doehlert matrix in optimization of experimental variables associated with the preconcentration and determination of vanadium and copper in seawater by inductively coupled plasma optical emission spectrometry

被引:156
作者
Ferreira, SLC [1 ]
Queiroz, AS [1 ]
Fernandes, MS [1 ]
dos Santos, HC [1 ]
机构
[1] Univ Fed Bahia, Inst Quim, Grp pesquisa Quim Analit, BR-40170229 Salvador, BA, Brazil
关键词
vanadium; copper; seawater; Doehlert matrix; inductively coupled plasma optical emission spectrometry (ICP OES);
D O I
10.1016/S0584-8547(02)00160-X
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
In the present paper a procedure for preconcentration and determination of vanadium and copper in seawater using inductively coupled plasma optical emission spectrometry (ICP OES) is proposed, which is based on solid-phase extraction of vanadium (IV), vanadium (V) and copper (II) ions as 1-(2-pyridylazo)-2-naphthol (PAN) complexes by active carbon. The optimization process was carried out using two-level full factorials and Doehlert matrix designs. Four variables (PAN mass, pH, active carbon mass and shaking time) were regarded as factors in the optimization. Results of the two-level full factorial design 2(4) with 16 runs for vanadium extraction, based on the variance analysis (ANOVA), demonstrated that the factors pH and active carbon mass, besides the interaction (pH X active carbon mass), are statistically significant. For copper, the ANOVA revealed that the factors PAN mass, pH and active carbon mass and the interactions (PAN mass X pH) and (pH X active carbon mass) are statistically significant. Doehlert designs were applied in order to determine the optimum conditions for extraction. The procedure proposed allowed the determination of vanadium and copper with detection limits (3sigma/S) of 73 and 94 ng l(-1), respectively. The precision, calculated as relative standard deviation (R.S.D.), was 1.22 and 1.37% for 12.50 mug l(-1) of vanadium and copper, respectively. The preconcentration factor was 80. The recovery achieved for determination of vanadium and copper in the presence of several cations demonstrated that this procedure improved the selectivity required for seawater analysis. The procedure was applied to the determination of vanadium and copper in seawater samples collected in Salvador City, Brazil. Results showed good agreement with other data reported in the literature. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:1939 / 1950
页数:12
相关论文
共 35 条
[11]  
Doehlert D.H., 1970, Appl. Stat, V19, P231
[12]   Application of Doehlert matrix and factorial designs in optimization of experimental variables associated with preconcentration and determination of molybdenum in sea-water by inductively coupled plasma optical emission spectrometry [J].
Ferreira, SLC ;
dos Santos, HC ;
Fernandes, MS ;
de Carvalho, MS .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2002, 17 (02) :115-120
[13]   Preconcentration and determination of copper and zinc in natural water samples by ICP-AES after complexation and sorption on amberlite XAD-2 [J].
Ferreira, SLC ;
dos Santos, HC ;
Ferreira, JR ;
de Araújo, NML ;
Costa, ACS ;
de Jesus, DS .
JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 1998, 9 (06) :525-530
[14]   Nickel determination in saline matrices by ICP-AES after sorption on Amberlite XAD-2 loaded with PAN [J].
Ferreira, SLC ;
de Brito, CF ;
Dantas, AF ;
de Araújo, NML ;
Costa, ACS .
TALANTA, 1999, 48 (05) :1173-1177
[15]   Designing experiments to optimise and validate the adsorptive stripping voltammetric determination of nimesulide [J].
Furlanetto, S ;
Orlandini, S ;
Aldini, G ;
Gotti, R ;
Dreassi, E ;
Pinzauti, S .
ANALYTICA CHIMICA ACTA, 2000, 413 (1-2) :229-239
[16]  
GARCIA LG, 1997, TALANTA, V44, P75
[17]   Application of Doehlert designs in the optimization of experimental variables associated with the simultaneous solvent extraction of several metals [J].
Gazquez, D ;
Sanchez-Vinas, M ;
Bagur, MG ;
Garcia, G .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1998, 13 (02) :105-108
[18]   Multivariate investigation of matrix effects in inductively coupled plasma atomic emission spectrometry using pneumatic or ultrasonic nebulization [J].
Grotti, M ;
Magi, E ;
Frache, R .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2000, 15 (01) :89-95
[19]   Determination by AAS of some trace heavy metal ions in some natural and biological samples after their preconcentration using newly chemically modified chloromethylated polystyrene-PAN ion-exchanger [J].
Kenawy, IMM ;
Hafez, MAH ;
Akl, MA ;
Lashein, RR .
ANALYTICAL SCIENCES, 2000, 16 (05) :493-500
[20]  
KENNISH M. J., 1994, PRATICAL HDB MARINE