Identification of dimethyidioctadecylammonium ion (m/z 550.6) and related species (m/z 522.6, 494.6) as a source of contamination in mass spectrometry

被引:27
作者
Manier, M. Lisa
Cornett, D. Shannon
Hachey, David L.
Caprioli, Richard M.
机构
[1] Vanderbilt Univ, Sch Med, Dept Chem, Mass Spectrometry Res Ctr, Nashville, TN 37232 USA
[2] Vanderbilt Univ, Sch Med, Dept Pharmacol, Mass Spectrometry Res Ctr, Nashville, TN 37232 USA
[3] Vanderbilt Univ, Sch Med, Dept Biochem, Mass Spectrometry Res Ctr, Nashville, TN 37232 USA
关键词
D O I
10.1016/j.jasms.2008.01.015
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Chemical contamination can be one of the more common problems encountered when performing trace-level analysis regardless of the analytical technique. Minimizing or eliminating background interferences can be a difficult task, so knowledge of the chemical composition of these contaminants can prove invaluable when it comes to identifying the source. Once the source is identified, proper steps may be taken to reduce or eliminate it. In this study, we report the identity of some commonly seen contaminants (m/z 550.6, 522.6, and 494.6) in electrospray ionization (EST) mass spectrometry (MS). Through MS, tandem MS, accurate-mass, and high-resolution measurements we have identified these background contaminants as being quaternary ammonium species that contain long-chain hydrocarbon groups, where m/z 3550.6 is a dimethyldioctaclecylammonium ion (C-18, C-18) and m/z 522.6 and 494.6 are similar in nature but have shorter alkyl-chain groups. The lipophilic nature of these compounds and the fact that they have molecular weights similar to lysophospholipids make them a frequent contaminant in lipidomic studies. The likely sources of these compounds are commonly used personal and household products.
引用
收藏
页码:666 / 670
页数:5
相关论文
共 10 条
[1]   MASS-SPECTRAL DETERMINATION OF LONG-CHAIN QUATERNARY AMINES IN MIXTURES [J].
COTTER, RJ ;
HANSEN, G .
ANALYTICA CHIMICA ACTA, 1982, 136 (APR) :135-142
[2]   Determination of the quaternary ammonium surfactant ditallowdimethylammonium in digested sludges and marine sediments by supercritical fluid extraction and liquid chromatography with postcolumn ion-pair formation [J].
Fernandez, P ;
Alder, AC ;
Suter, MJF ;
Giger, W .
ANALYTICAL CHEMISTRY, 1996, 68 (05) :921-929
[3]   ENVIRONMENTAL FATE AND EFFECTS OF DEEDMAC - A NEW RAPIDLY BIODEGRADABLE CATIONIC SURFACTANT FOR USE IN FABRIC SOFTENERS [J].
GIOLANDO, ST ;
RAPAPORT, RA ;
LARSON, RJ ;
FEDERLE, TW ;
STALMANS, M ;
MASSCHELEYN, P .
CHEMOSPHERE, 1995, 30 (06) :1067-1083
[4]  
HIRONOBU K, 1978, J PHYS CHEM-US, V82, P1710
[5]   ANOMALOUS LIQUID-CHROMATOGRAPHIC RESULTS ORIGINATING FROM THE PRESENCE OF SOAP RESIDUES AND THE USE OF NYLON FILTERS [J].
HUGHES, DE ;
BRAMER, AM .
JOURNAL OF CHROMATOGRAPHY, 1987, 408 :296-302
[6]   On the nature of the chemical noise in MALDI mass spectra [J].
Krutchinsky, AN ;
Chait, BT .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2002, 13 (02) :129-134
[7]   Volatile polydimethylcyclosiloxanes in the ambient laboratory air identified as source of extreme background signals in nanoelectrospray mass spectrometry [J].
Schlosser, A ;
Volkmer-Engert, R .
JOURNAL OF MASS SPECTROMETRY, 2003, 38 (05) :523-525
[8]   Cyclic polyamide oligomers extracted from nylon 66 membrane filter disks as a source of contamination in liquid chromatography/mass spectrometry [J].
Tran, JC ;
Doucette, AA .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2006, 17 (05) :652-656
[9]   Plasticizer contamination from vacuum system o-rings in a quadrupole ion trap mass spectrometer [J].
Verge, KM ;
Agnes, GR .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2002, 13 (08) :901-905
[10]   Rubber stoppers as sources of contaminants in electrospray analysis of peptides and proteins [J].
Zhang, XK ;
Dutky, RC ;
Fales, HM .
ANALYTICAL CHEMISTRY, 1996, 68 (18) :3288-3289