Measurements of calcium isotopes and isotope ratios: a new method based on helium plasma source "off-cone" sampling time-of-flight mass spectrometry

被引:11
作者
Duan, YX [1 ]
Su, YX [1 ]
Jin, Z [1 ]
Koby, M [1 ]
Majidi, V [1 ]
机构
[1] Univ Calif Los Alamos Natl Lab, Div Chem, Los Alamos, NM 87545 USA
关键词
D O I
10.1039/b102735m
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Operation of a helium-based low-power microwave plasma under "off-cone" sampling mode can lead to significant background suppression without sacrificing the analyte signal intensity. The nearly clean background spectrum obtained with "off-cone" sampling provides a unique approach for isotope ratio measurements, especially for low-mass elements that are often problematic. In this work, calcium isotopes and isotope ratios are quantitatively measured using "off-cone" sampling with microwave plasma time-of-flight mass spectrometry. The viability of measurements for all calcium isotopes, from the most abundant isotope (Ca-40) to the least abundant isotope (Ca-46), has been established for this technique. Several calcium isotope ratios are measured and calculated through both elemental calcium ion peaks and molecular calcium ion peaks. The relative standard deviations (RSD) for isotope ratios measured are in a range of 1.2 to 2.5% for commonly used major calcium isotopes. The absolute measurement errors are around 0.8% or less in most cases for major isotopes.
引用
收藏
页码:756 / 761
页数:6
相关论文
共 28 条
[1]   MASS-SPECTROMETRIC METHODS FOR STUDYING NUTRIENT MINERAL AND TRACE-ELEMENT ABSORPTION AND METABOLISM IN HUMANS USING STABLE ISOTOPES - A REVIEW [J].
CREWS, HM ;
DUCROS, V ;
EAGLES, J ;
MELLON, FA ;
KASTENMAYER, P ;
LUTEN, JB ;
MCGAW, BA .
ANALYST, 1994, 119 (11) :2491-2514
[2]   Design and development of a highly sensitive, field portable plasma source instrument for on-line liquid stream monitoring and real-time sample analysis [J].
Duan, YX ;
Su, YX ;
Jin, Z ;
Abeln, SP .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2000, 71 (03) :1557-1563
[3]   Development of a new high-efficiency thermal ionization source for mass spectrometry [J].
Duan, YX ;
Chamberlin, EP ;
Olivares, JA .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1997, 161 (1-3) :27-39
[4]   A field portable plasma source monitor for real-time air particulate monitoring [J].
Duan, YX ;
Su, YX ;
Jin, Z ;
Abeln, SP .
ANALYTICAL CHEMISTRY, 2000, 72 (07) :1672-1679
[5]   High-precision measurement of calcium isotopes in carbonates and related materials by multiple collector inductively coupled plasma mass spectrometry (MC-ICP-MS) [J].
Halicz, L ;
Galy, A ;
Belshaw, NS ;
O'Nions, RK .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (12) :1835-1838
[6]   ACCURATE MEASUREMENT OF STABLE ISOTOPES CA-46 AND CA-48 IN HUMAN FECES, PLASMA, AND URINE IN RELATION TO HUMAN-NUTRITION OF CALCIUM [J].
JANGHORBANI, M ;
SUNDARESAN, A ;
YOUNG, VR .
CLINICA CHIMICA ACTA, 1981, 113 (03) :267-280
[7]   ALLEVIATION OF OVERLAP INTERFERENCES FOR DETERMINATION OF POTASSIUM ISOTOPE RATIOS BY INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
JIANG, SJ ;
HOUK, RS ;
STEVENS, MA .
ANALYTICAL CHEMISTRY, 1988, 60 (11) :1217-1221
[8]   QUANTITATION OF STABLE ISOTOPIC TRACERS OF CALCIUM BY FAST-ATOM-BOMBARDMENT MASS-SPECTROMETRY [J].
JIANG, X ;
SMITH, DL .
ANALYTICAL CHEMISTRY, 1987, 59 (21) :2570-2574
[9]   QUANTITATION OF METAL ISOTOPE RATIOS BY LASER-DESORPTION TIME-OF-FLIGHT MASS-SPECTROMETRY [J].
KOUMENIS, IL ;
VESTAL, ML ;
YERGEY, AL ;
ABRAMS, S ;
DEMING, SN ;
HUTCHENS, TW .
ANALYTICAL CHEMISTRY, 1995, 67 (24) :4557-4564
[10]  
LUTWAK L, 1969, AM J CLIN NUTR, V22, P771