Measurements of calcium isotopes and isotope ratios: a new method based on helium plasma source "off-cone" sampling time-of-flight mass spectrometry

被引:11
作者
Duan, YX [1 ]
Su, YX [1 ]
Jin, Z [1 ]
Koby, M [1 ]
Majidi, V [1 ]
机构
[1] Univ Calif Los Alamos Natl Lab, Div Chem, Los Alamos, NM 87545 USA
关键词
D O I
10.1039/b102735m
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Operation of a helium-based low-power microwave plasma under "off-cone" sampling mode can lead to significant background suppression without sacrificing the analyte signal intensity. The nearly clean background spectrum obtained with "off-cone" sampling provides a unique approach for isotope ratio measurements, especially for low-mass elements that are often problematic. In this work, calcium isotopes and isotope ratios are quantitatively measured using "off-cone" sampling with microwave plasma time-of-flight mass spectrometry. The viability of measurements for all calcium isotopes, from the most abundant isotope (Ca-40) to the least abundant isotope (Ca-46), has been established for this technique. Several calcium isotope ratios are measured and calculated through both elemental calcium ion peaks and molecular calcium ion peaks. The relative standard deviations (RSD) for isotope ratios measured are in a range of 1.2 to 2.5% for commonly used major calcium isotopes. The absolute measurement errors are around 0.8% or less in most cases for major isotopes.
引用
收藏
页码:756 / 761
页数:6
相关论文
共 28 条
[22]   Measurements of Ca-44:Ca-43 and Ca-42:Ca-43 isotopic ratios in urine using high resolution inductively coupled plasma mass spectrometry [J].
Sturup, S ;
Hansen, M ;
Molgaard, C .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (09) :919-923
[23]   Helium plasma source time-of-flight mass spectrometry: Off-cone sampling for elemental analysis [J].
Su, YX ;
Duan, YX ;
Jin, Z .
ANALYTICAL CHEMISTRY, 2000, 72 (11) :2455-2462
[25]   Precise measurement of isotope ratios with a double-focusing magnetic sector ICP mass spectrometer [J].
Vanhaecke, F ;
Moens, L ;
Dams, R ;
Taylor, P .
ANALYTICAL CHEMISTRY, 1996, 68 (03) :567-569
[26]   Applicability of high-resolution ICP mass spectrometry for isotope ratio measurements [J].
Vanhaecke, F ;
Moens, L ;
Dams, R ;
Papadakis, I ;
Taylor, P .
ANALYTICAL CHEMISTRY, 1997, 69 (02) :268-273
[27]   ISOTOPE RATIO MEASUREMENTS OF URINARY CALCIUM WITH A THERMAL IONIZATION PROBE IN A QUADRUPOLE MASS-SPECTROMETER [J].
YERGEY, AL ;
VIEIRA, NE ;
HANSEN, JW .
ANALYTICAL CHEMISTRY, 1980, 52 (12) :1811-1814
[28]   Calcium isotopes in the marine environment and the oceanic calcium cycle [J].
Zhu, P ;
Macdougall, JD .
GEOCHIMICA ET COSMOCHIMICA ACTA, 1998, 62 (10) :1691-1698