High-speed, high-resolution optical coherence tomography (OCT) imaging of the human retina is demonstrated using a frequency-swept laser at 850 nm. A compact external cavity semiconductor laser design, optimized for swept-source ophthalmic OCT, is described. The laser enables an effective 16 kHz sweep rate with > 10 mm coherence length and a tuning range of similar to 35 nm full width at half-maximum, yielding an axial resolution of < 7 mu m in tissue. (c) 2007 Optical Society of America.
引用
收藏
页码:361 / 363
页数:3
相关论文
共 16 条
[1]   Numerical study of wavelength-swept semiconductor ring lasers: the role of refractive-index nonlinearities in semiconductor optical amplifiers and implications for biomedical imaging applications [J].
Bilenca, A ;
Yun, SH ;
Tearney, GJ ;
Bouma, BE .
OPTICS LETTERS, 2006, 31 (06) :760-762
[2]   Sensitivity advantage of swept source and Fourier domain optical coherence tomography [J].
Choma, MA ;
Sarunic, MV ;
Yang, CH ;
Izatt, JA .
OPTICS EXPRESS, 2003, 11 (18) :2183-2189
[3]   Improved signal-to-noise ratio in spectral-domain compared with time-domain optical coherence tomography [J].
de Boer, JF ;
Cense, B ;
Park, BH ;
Pierce, MC ;
Tearney, GJ ;
Bouma, BE .
OPTICS LETTERS, 2003, 28 (21) :2067-2069
[4]   Ultrahigh-resolution ophthalmic optical coherence tomography [J].
Drexler, W ;
Morgner, U ;
Ghanta, RK ;
Kärtner, FX ;
Schuman, JS ;
Fujimoto, JG .
NATURE MEDICINE, 2001, 7 (04) :502-507
[5]   MEASUREMENT OF INTRAOCULAR DISTANCES BY BACKSCATTERING SPECTRAL INTERFEROMETRY [J].
FERCHER, AF ;
HITZENBERGER, CK ;
KAMP, G ;
ELZAIAT, SY .
OPTICS COMMUNICATIONS, 1995, 117 (1-2) :43-48
[6]  
Häusler G, 1998, J BIOMED OPT, V3, P21, DOI 10.1117/1.429899
[7]   OPTICAL COHERENCE TOMOGRAPHY OF THE HUMAN RETINA [J].
HEE, MR ;
IZATT, JA ;
SWANSON, EA ;
HUANG, D ;
SCHUMAN, JS ;
LIN, CP ;
PULIAFITO, CA ;
FUJIMOTO, JG .
ARCHIVES OF OPHTHALMOLOGY, 1995, 113 (03) :325-332
[8]   OPTICAL COHERENCE TOMOGRAPHY [J].
HUANG, D ;
SWANSON, EA ;
LIN, CP ;
SCHUMAN, JS ;
STINSON, WG ;
CHANG, W ;
HEE, MR ;
FLOTTE, T ;
GREGORY, K ;
PULIAFITO, CA ;
FUJIMOTO, JG .
SCIENCE, 1991, 254 (5035) :1178-1181
[9]   Three-dimensional and C-mode OCT imaging with a compact, frequency swept laser source at 1300 nm [J].
Huber, R ;
Wojtkowski, M ;
Fujimoto, JG ;
Jiang, JY ;
Cable, AE .
OPTICS EXPRESS, 2005, 13 (26) :10523-10538
[10]   Amplified, frequency swept lasers for frequency domain reflectometry and OCT imaging: design and scaling principles [J].
Huber, R ;
Wojtkowski, M ;
Taira, K ;
Fujimoto, JG ;
Hsu, K .
OPTICS EXPRESS, 2005, 13 (09) :3513-3528